Differences between pelvic skin and bone landmark identification in different seated positions on spinal-cord injured subjects

The purpose of this paper was to determine the differences between internal and external pelvic landmark locations in different seating positions. A computer tool developed for the registration of two series of images was used to obtain the internal geometry. First, images of the pelvis were acquired by magnetic resonance imaging (MRI) for each subject, in a supine position; internal landmarks were then identified on the images. Second, ultrasound images of the iliac crests were acquired in four seated positions. A registration algorithm was applied to obtain the transformation matrix between the two image reference systems. The MRI anatomical landmarks were, therefore, transferred into the ultrasound referential, to obtain their three-dimensional (3-D) location in the different seating positions. The external landmarks in those seated positions were identified with a 3-D digitizer. The results revealed that generally the internal and external coordinates of corresponding landmarks are statistically different. The differences are not only due to soft tissue thickness but also to different interpretations of the landmarks' locations between the supine and the seated postures. However, these differences generally did not affect significantly the accuracy with which orientation indexes can be estimated (pelvic tilt, obliquity, transverse rotation). Correlations were found between the internal and external coordinates, implying that linear regressions can be established.

[1]  J. Dansereau,et al.  Analysis of sliding and pressure distribution during a repositioning of persons in a simulator chair , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[2]  Matthew P. Reed,et al.  Methods for Measuring and Representing Automobile Occupant Posture , 1999 .

[3]  R Aissaoui,et al.  Assessment of geometric and mechanical parameters in wheelchair seating: a variability study. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[4]  Lionel Carrat,et al.  Percutaneous Iliosacral Screw Placement Using Image Guided Techniques , 1998, Clinical orthopaedics and related research.

[5]  D M Brienza,et al.  A system for the analysis of seat support surfaces using surface shape control and simultaneous measurement of applied pressures. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[6]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.

[7]  Yuntao Cui,et al.  Locating the Pelvis in the Seated Automobile Driver , 1996 .

[8]  M. Polansky,et al.  The Influence of Different Sitting Positions on Cervical and Lumbar Posture , 1996, Spine.

[9]  A F Mak,et al.  Posture effect on seating interface biomechanics: comparison between two seating cushions. , 1996, Archives of physical medicine and rehabilitation.

[10]  Brenda Smart Positioning in a Wheelchair: A guide for professional caregivers of the disabled adult , 1996 .

[11]  Carol A. C. Flannagan,et al.  Evaluation of the SAE J826 3-D Manikin Measures of Driver Positioning and Posture , 1994 .

[12]  D. Hobson,et al.  Seated Lumbar/Pelvic Alignment: A Comparison Between Spinal Cord-Injured and Noninjured Groups , 1992, Spine.

[13]  Aurelio Cappozzo,et al.  Three-dimensional analysis of human walking: Experimental methods and associated artifacts☆ , 1991 .

[14]  Michele Harms Effect of Wheelchair Design on Posture and Comfort of Users , 1990 .

[15]  D R Pedersen,et al.  A comparison of the accuracy of several hip center location prediction methods. , 1990, Journal of biomechanics.

[16]  J. T. Bryant,et al.  Method for Determining Vertebral Body Positions in the Sagittal Plane Using Skin Markers , 1989, Spine.

[17]  Nwaobi Om,et al.  Mechanical and anatomic hip flexion angles on seating children with cerebral palsy. , 1988 .

[18]  D. Hobson,et al.  Mechanical and anatomic hip flexion angles on seating children with cerebral palsy. , 1988, Archives of physical medicine and rehabilitation.

[19]  R. Burdett,et al.  Reliability and validity of four instruments for measuring lumbar spine and pelvic positions. , 1986, Physical therapy.

[20]  G Selvik,et al.  Mobility of the pubic symphysis. In vivo measurements with an electromechanic method and a roentgen stereophotogrammetric method. , 1984, Clinical orthopaedics and related research.

[21]  C. Buchanan,et al.  Quantitative Description of Two Sitting Postures , 1984 .

[22]  C. Buchanan,et al.  Quantitative description of two sitting postures. With and without a lumbar support pillow. , 1984, Physical therapy.

[23]  G. Andersson,et al.  The Influence of Backrest Inclination and Lumbar Support on Lumbar Lordosis , 1979, Spine.

[24]  Richard G. Snyder Link System of the Human Torso , 1972 .