New Design Detail to Enhance the Seismic Performance of Ordinary Reinforced Partially Grouted Masonry Structures

AbstractRecent studies have shown that in the event of a strong earthquake, partially grouted (PG) masonry walls would most likely not perform according to code expectations. The research reported herein is focused on introducing an economically competitive design detail to enhance the seismic performance and safety index of PG reinforced masonry shear walls. Besides the conventional design details of single grouted vertical cells with single bond beams, two other details called double grouted vertical cells with double bond beams, and double grouted vertical cells with single bond beams plus joint reinforcement, were constructed and tested in this study. Test results demonstrated that the single grouted wall failed in a low ductility shear-dominated mode, while the modified design details resulted in a change to the high ductility shear failure mode. Results of nonlinear static and incremental dynamic analyses showed that using the proposed enhanced detail can significantly improve the seismic performanc...

[1]  Franklin Moon,et al.  Simplified micro modeling of partially grouted masonry assemblages , 2015 .

[2]  G. Milani Simple homogenization model for the non-linear analysis of in-plane loaded masonry walls , 2011 .

[3]  Paulo B. Lourenço,et al.  CONTINUUM MODEL FOR MASONRY: PARAMETER ESTIMATION AND VALIDATION , 1998 .

[4]  Franklin Moon,et al.  Enhancement of seismic performance of partially grouted reinforced masonry shear walls , 2014 .

[5]  Franklin Moon,et al.  Enhancement of lateral in-plane capacity of partially grouted concrete masonry shear walls , 2016 .

[6]  Ivan Bartoli,et al.  A data fusion approach for progressive damage quantification in reinforced concrete masonry walls , 2013 .

[7]  P. B. Shing,et al.  An appraisal of smeared crack models for masonry shear wall analysis , 1991 .

[8]  T. Paulay,et al.  Seismic Design of Reinforced Concrete and Masonry Buildings , 1992 .

[9]  Giuseppe Giambanco,et al.  Numerical analysis of masonry structures via interface models , 2001 .

[10]  Mohamed A. ElGawady,et al.  Static Cyclic Response of Partially Grouted Masonry Shear Walls , 2012 .

[11]  J. Ingham,et al.  Experimental In-Plane Shear Strength Investigation of Reinforced Concrete Masonry Walls , 2006 .

[12]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[13]  Andreas Stavridis,et al.  Finite-Element Modeling of Nonlinear Behavior of Masonry-Infilled RC Frames , 2010 .

[14]  Benson Shing,et al.  ENHANCEMENT OF SEISMIC PERFORMANCE AND DESIGN OF PARTIALLY GROUTED REINFORCED MASONRY BUILDINGS , 2014 .

[15]  P. Lourenço,et al.  Multisurface Interface Model for Analysis of Masonry Structures , 1997 .

[16]  K. Willam,et al.  Numerical modeling of masonry-infilled RC frames subjected to seismic loads , 2011 .

[17]  C. Adam,et al.  Numerical modeling of the in-plane behavior of historical brick masonry walls , 2011 .

[18]  Ivan Bartoli,et al.  Damage detection of concrete masonry structures by enhancing deformation measurement using DIC , 2016, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[19]  Franklin Moon,et al.  In-Plane Behavior of Partially Grouted Reinforced Concrete Masonry Shear Walls , 2010 .

[20]  Arturo E. Schultz Seismic Resistance of Partially-Grouted Masonry Shear Walls , 1996 .

[21]  Kok Choon Voon In-plane Seismic Design of Concrete Masonry Structures , 2007 .