Real-time three-dimensional motion analysis for patient positioning verification.

BACKGROUND AND PURPOSE This paper describes the technology and methods involved in a system for automatically checking the position of patients at radiotherapy units. This is proposed for improving the accuracy in the irradiation geometrical set-up, which is a crucial factor in radiotherapy quality control. MATERIALS AND METHODS The system is based on real-time opto-electronics and close-range photogrammetry and detects multiple passive markers placed on selected patient skin landmarks. Patient alignment and position monitoring is carried out by comparing the current three-dimensional positions of the markers with those of an initial reference position acquired during the simulation procedure and/or the first irradiation session. The system was used to measure the accuracy of conventional laser centering techniques for patient repositioning. Inaccuracies due to breathing and random movements were also taken into account. Professional technicians were asked to reposition three volunteer subjects carefully using a traditional laser centering procedure. RESULTS The results revealed significant repositioning errors even in highly controlled conditions, affecting particularly body areas relatively far from the skin reference points used for laser alignment. CONCLUSIONS The outcome of the experimental application of this technology confirms its potential as a tool for patient repositioning and automatic detection of any errors caused by breathing or other unpredictable movements. The real-time feedback on the patient's position given by the system provides operators with appropriate visual indices and allows them to take suitable countermeasures in case of significant failures. In addition, the use of the system output for automatic position control is envisaged.

[1]  G. Ferrigno,et al.  An algorithm for 3-D automatic movement detection by means of standard TV cameras , 1990, IEEE Transactions on Biomedical Engineering.

[2]  Paul Allard,et al.  Three-dimensional analysis of human movement , 1995 .

[3]  R Mohan,et al.  The role of uncertainty analysis in treatment planning. , 1991, International journal of radiation oncology, biology, physics.

[4]  G Ferrigno,et al.  Optoelectronic techniques for patient repositioning in radiotherapy. , 1996, Technology and health care : official journal of the European Society for Engineering and Medicine.

[5]  Michael G. Herman,et al.  CLINICAL USE OF ON-LINE PORTAL IMAGING FOR DAILY PATIENT TREATMENT VERIFICATION , 1994 .

[6]  L P Adams,et al.  Determining locations of intracerebral lesions for proton radiotherapy. , 1993, Physics in medicine and biology.

[7]  G Ferrigno,et al.  Three-dimensional optical analysis of chest wall motion. , 1994, Journal of applied physiology.

[8]  Giancarlo Ferrigno,et al.  Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing , 1985, IEEE Transactions on Biomedical Engineering.

[9]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[10]  T. Sarrazin,et al.  Utilisation d'un système d'imagerie en temps réel dans le contrôle quotidien de patients traités par irradiation pour un cancer thoracique , 1997 .

[11]  Giancarlo Ferrigno,et al.  Pattern recognition in 3D automatic human motion analysis , 1990 .

[12]  R K Valicenti,et al.  An analysis of intratreatment and intertreatment displacements in pelvic radiotherapy using electronic portal imaging. , 1996, International journal of radiation oncology, biology, physics.

[13]  R K Valicenti,et al.  Is weekly port filming adequate for verifying patient position in modern radiation therapy? , 1994, International journal of radiation oncology, biology, physics.

[14]  A. Dutreix When and how can we improve precision in radiotherapy? , 1984, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  R. L. Harris,et al.  The use of an optical outlining system for weekly on-set verification of patients with carcinoma of the breast. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  P. Munro,et al.  Portal Imaging Technology: Past, Present, and Future. , 1995, Seminars in radiation oncology.

[17]  N G Burnet,et al.  Accuracy of patient positioning during radiotherapy for bladder and brain tumours. , 1999, Clinical oncology (Royal College of Radiologists (Great Britain)).

[18]  A R Smith,et al.  Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements. , 1992, International journal of radiation oncology, biology, physics.

[19]  R Orecchia,et al.  [Assessment of the accuracy of position in breast irradiation with isocentric technique using an electronic system to acquire portal images]. , 1997, La Radiologia medica.