A novel method for ultra-high-frequency partial discharge localization in power transformers using the particle swarm optimization algorithm

Nowadays, the localization of partial discharge (PD) in power transformers by measurement of ultra-high-frequency (UHF) electromagnetic (EM) waves from a PD source is receiving more attention. This method is based on comparing the differences in the arrival times, to antennas in the transformer, of EM waves emitted from the PD source. From the measured UHF signal, and factoring in the influence of the transformer active part on the EM wave propagation, the correct determination of an EM wave arrival time in the localization algorithm is a critical task that influences the accuracy of the UHF PD localization method. Nearly all weak points in the dielectric system of power transformers generate PD. These discharges gradually degrade the insulation, leading to transformer failure. It is possible to detect these defects in the early stages of PD generation by measuring and analyzing the PD data. Suitable maintenance and repair strategies can then be implemented.

[1]  M. Judd,et al.  An optimal algorithm for applying wavelet transform in identifying the arrival time of PD pulse in a UHF detection system , 2007, 2007 42nd International Universities Power Engineering Conference.

[2]  A. Akbari,et al.  Investigating practical experiments of partial discharge localization in transformers using winding modeling , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Asghar Akbari,et al.  Partial discharge localization in transformer windings using multi-conductor transmission line model , 2008 .

[4]  M.D. Judd Radiometric partial discharge detection , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[5]  A. Nasiri,et al.  A hybrid transformer model for determination of partial discharge location in transformer winding , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Peter Crossley,et al.  Experimental investigation into the propagation of partial discharge pulses in transformers , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[7]  Hossein Borsi,et al.  Transfer function-based partial discharge localization in power transformers: a feasibility study , 2002 .

[8]  M. D. Judd,et al.  Experimental comparison of UHF sensor types for PD location applications , 2009, 2009 IEEE Electrical Insulation Conference.

[9]  J.J. Smit,et al.  Sensitivity Check of Internal Sensor for Power Transformer Partial Discharge Measurements , 2006, 2006 IEEE 8th International Conference on Properties & applications of Dielectric Materials.

[10]  A. Cavallini,et al.  Analysis on partial discharge propagation and detection in MV power transformers , 2009, 2009 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[11]  S. Tenbohlen,et al.  Performance Check and Sensitivity Verification for UHF PD Measurements on Power Transformers , 2007 .

[12]  J. Lopez-Roldan,et al.  Optimisation of a sensor for onsite detection of partial discharges in power transformers by the UHF method , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Wei Wang,et al.  Partial discharge location in power transformers using wideband RF detection , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  S. Tenbohlen,et al.  FUNDAMENTAL CHARACTERISTICS OF UHF PD PROBES AND THE RADIATION BEHAVIOR OF PD SOURCES IN POWER TRANSFORMERS , 2009 .

[15]  T. Leibfried,et al.  Enhanced signal processing for conventional and unconventional PD measuring methods: Wavelet de-noising, automatic detection algorithms and averaging for arrival time-based PD location in transformers and power cables , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[16]  S. Tenbohlen,et al.  Partial discharge measurement in the ultra high frequency (UHF) range , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  S. Tenbohlen,et al.  Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  Chengke Zhou,et al.  An Algorithm for Indentifying the Arrival Time of PD Pulses for PD Source Location , 2008, 2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[19]  T.R. Blackburn,et al.  Partial discharge measurement for transformer insulation using wide and narrow band methods in ultra high frequency range , 2009, 2009 Australasian Universities Power Engineering Conference.

[20]  M.D. Judd,et al.  Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretation , 2005, IEEE Electrical Insulation Magazine.

[21]  K. Raja,et al.  Comparative investigations on UHF and acoustic PD detection sensitivity in transformers , 2002, Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316).