Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation.

BACKGROUND Accurate imaging assessment of aortic annulus (AoA) dimension is paramount to decide on the correct transcatheter heart valve (THV) size for patients undergoing transcatheter aortic valve implantation (TAVI). We evaluated the feasibility and accuracy of a novel automatic framework for multidetector row computed tomography (MDCT)-based TAVI planning. METHODS Among 122 consecutive patients undergoing TAVI and retrospectively reviewed for this study, 104 patients with preoperative MDCT of sufficient quality were enrolled and analyzed with the proposed software. Fully automatic (FA) and semi-automatic (SA) AoA measurements were compared to manual measurements, with both automated and manual-based interobserver variability (IOV) being assessed. Finally, the effect of these measures on hypothetically selected THV size was evaluated against the implanted size, as well as with respect to manually-derived sizes. RESULTS FA analysis was feasible in 92.3% of the cases, increasing to 100% if using the SA approach. Automatically-extracted measurements showed excellent agreement with manually-derived ones, with small biases and narrow limits of agreement, and comparable to the interobserver agreement. The SA approach presented a statistically lower IOV than manual analysis, showing the potential to reduce interobserver sizing disagreements. Moreover, the automated approaches displayed close agreement with the implanted sizes, similar to the ones obtained by the experts. CONCLUSION The proposed automatic framework provides an accurate and robust tool for AoA measurements and THV sizing in patients undergoing TAVI.

[1]  T van Walsum,et al.  Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study. , 2010, Medical physics.

[2]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[3]  S. Achenbach,et al.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). , 2012, Journal of cardiovascular computed tomography.

[4]  P. Wenaweser,et al.  Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. , 2014, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[5]  Raimund Erbel,et al.  Open issues in transcatheter aortic valve implantation. Part 1: patient selection and treatment strategy for transcatheter aortic valve implantation. , 2014, European heart journal.

[6]  M. Mack,et al.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. , 2016, The New England journal of medicine.

[7]  Patrizio Lancellotti,et al.  The use of imaging in new transcatheter interventions: an EACVI review paper. , 2016, European heart journal cardiovascular Imaging.

[8]  Stuart J Pocock,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[9]  L. Quint,et al.  Proximal thoracic aortic diameters: transesophageal-echocardiography- versus computed-tomography-derived measurements. , 2016, Clinical imaging.

[10]  Jan D’hooge,et al.  Fully Automatic 3-D-TEE Segmentation for the Planning of Transcatheter Aortic Valve Implantation , 2017, IEEE Transactions on Biomedical Engineering.

[11]  J. Leipsic,et al.  A practical guide to multimodality imaging of transcatheter aortic valve replacement. , 2012, JACC. Cardiovascular imaging.

[12]  S. Nitzsche,et al.  CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation , 2015, The International Journal of Cardiovascular Imaging.

[13]  A. Schuhbaeck,et al.  Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI). , 2014, European journal of radiology.

[14]  Adnan Kastrati,et al.  Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. , 2013, JACC. Cardiovascular imaging.

[15]  M. Monaghan,et al.  How to assess aortic annular size before transcatheter aortic valve implantation (TAVI): the role of echocardiography compared with other imaging modalities , 2014, Heart.

[16]  Jan D'hooge,et al.  Aortic Valve Tract Segmentation From 3D-TEE Using Shape-Based B-Spline Explicit Active Surfaces , 2016, IEEE Transactions on Medical Imaging.

[17]  M. Morice,et al.  Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. , 2013, JACC. Cardiovascular interventions.

[18]  Sasa Grbic,et al.  Advanced Transcatheter Aortic Valve Implantation (TAVI) Planning from CT with ShapeForest , 2014, MICCAI.

[19]  Jeroen J. Bax,et al.  Automated assessment of the aortic root dimensions with multidetector row computed tomography. , 2011, The Annals of thoracic surgery.

[20]  J. Webb,et al.  The transcatheter valve technology pipeline for treatment of adult valvular heart disease. , 2016, European heart journal.

[21]  H. Marquering,et al.  Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation , 2015, The International Journal of Cardiovascular Imaging.

[22]  T. Ryan,et al.  Automated Quantitative 3-Dimensional Modeling of the Aortic Valve and Root by 3-Dimensional Transesophageal Echocardiography in Normals, Aortic Regurgitation, and Aortic Stenosis: Comparison to Computed Tomography in Normals and Clinical Implications , 2013, Circulation. Cardiovascular imaging.

[23]  Mark J Monaghan,et al.  Recommendations for comprehensive intraprocedural echocardiographic imaging during TAVR. , 2015, JACC. Cardiovascular imaging.

[24]  Paul Schoenhagen,et al.  Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): analysis of interchangeability. , 2015, Journal of cardiovascular computed tomography.

[25]  C. Hengstenberg,et al.  Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography. , 2013, International journal of cardiology.

[26]  F. Mohr,et al.  Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing. , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.