Minimizing the undesirable effect of coupling capacitor voltage transformer on DFT-based phasor estimation method
暂无分享,去创建一个
Ali Reza Seifi | Alireza Bagheri | Mohsen Tajdinian | Mehdi Allahbakhshi | Mehdi Allahbakhshi | Alireza Bagheri
[1] Mario Paolone,et al. Enhanced Interpolated-DFT for Synchrophasor Estimation in FPGAs: Theory, Implementation, and Validation of a PMU Prototype , 2014, IEEE Transactions on Instrumentation and Measurement.
[2] Mario Paolone,et al. Iterative-Interpolated DFT for Synchrophasor Estimation: A Single Algorithm for P- and M-Class Compliant PMUs , 2018, IEEE Transactions on Instrumentation and Measurement.
[3] R. K. Patnaik,et al. Dynamic phasor and frequency estimation of time-varying power system signals , 2013 .
[4] Yilu Liu,et al. A Clarke Transformation-Based DFT Phasor and Frequency Algorithm for Wide Frequency Range , 2018, IEEE Transactions on Smart Grid.
[5] M. Kezunovic,et al. An Adaptive Phasor Estimator for Power System Waveforms Containing Transients , 2012, IEEE Transactions on Power Delivery.
[6] B. Kaszteny,et al. Distance relays and capacitive voltage transformers balancing speed and transient overreach , 2000 .
[7] António Pina Martins. A DFT‐based phasor estimation method for power electronics converter control and protection under strong grid voltage perturbations , 2009 .
[8] Eugeniusz Rosolowski,et al. Dynamic compensation of capacitive voltage transformers , 1998 .
[9] Abouzar Rahmati,et al. Real-time electrical variables estimation based on recursive wavelet transform , 2015 .
[10] M. S. Sachdev,et al. Phasor estimation technique to reduce the impact of coupling capacitor voltage transformer transients , 2008 .
[11] Rastko Zivanovic,et al. Phasor measurement based on IEC 61850-9-2 and Kalman–Filtering , 2014 .
[12] Daniel Belega,et al. Sine-wave parameter estimation by interpolated DFT method based on new cosine windows with high interference rejection capability , 2014, Digit. Signal Process..
[13] Tarlochan S. Sidhu,et al. A Simple Synchrophasor Estimation Algorithm Considering IEEE Standard C37.118.1-2011 and Protection Requirements , 2013, IEEE Transactions on Instrumentation and Measurement.
[14] Arun G. Phadke,et al. Synchronized Phasor Measurements and Their Applications , 2008 .
[15] Badri Ram,et al. Power System Protection and Switchgear , 2011 .
[16] Mohsen Tajdinian,et al. A new statistical-based algorithm for CT saturation detection utilizing residual-based similarity index , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).
[17] M. S. Sachdev,et al. Strengths and limitations of a new phasor estimation technique to reduce CCVT impact in distance protection , 2010 .
[18] Ali Reza Seifi,et al. Analytical discrete Fourier transformer-based phasor estimation method for reducing transient impact of capacitor voltage transformer , 2017 .
[19] Dario Petri,et al. Accuracy Analysis and Enhancement of DFT-Based Synchrophasor Estimators in Off-Nominal Conditions , 2012, IEEE Transactions on Instrumentation and Measurement.
[20] Mohsen Tajdinian,et al. Comprehensive and innovative method for dynamic phasor and frequency estimation , 2015, The 9th Power Systems Protection and Control Conference (PSPC2015).
[21] José Antonio de la O. Serna,et al. Taylor–Kalman–Fourier Filters for Instantaneous Oscillating Phasor and Harmonic Estimates , 2012, IEEE Transactions on Instrumentation and Measurement.
[22] Ali Reza Seifi,et al. Transient Stability of Power Grids Comprising Wind Turbines: New Formulation, Implementation, and Application in Real-Time Assessment , 2019, IEEE Systems Journal.
[23] Ali Reza Seifi,et al. Framework for current transformer saturation detection and waveform reconstruction , 2018 .
[24] Weighted least error squares based variable window phasor estimator for distance relaying application , 2011 .
[25] José Antonio de la O. Serna,et al. Synchrophasor Measurement With Polynomial Phase-Locked-Loop Taylor-Fourier Filters , 2015, IEEE Trans. Instrum. Meas..
[26] Alireza Bagheri,et al. Utilizing Rogowski coil for saturation detection and compensation in iron core current transformer , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).
[27] Ali Reza Seifi,et al. Half-cycle method for exponentially DC components elimination applicable in phasor estimation , 2017 .
[28] Ali Reza Seifi,et al. Sensitivity-based approach for real-time evaluation of transient stability of wind turbines interconnected to power grids , 2018 .
[29] George N. Korres,et al. Real‐time implementation of digital relay models using MATLAB/SIMULINK and RTDS , 2010 .
[30] Shahram Montaser Kouhsari,et al. An analytical approach for removal of decaying DC component considering frequency deviation , 2016 .
[31] José Antonio de la O. Serna,et al. Dynamic Harmonic Analysis Through Taylor–Fourier Transform , 2011, IEEE Transactions on Instrumentation and Measurement.
[32] Daniel Belega,et al. Accuracy Analysis of the Multicycle Synchrophasor Estimator Provided by the Interpolated DFT Algorithm , 2013, IEEE Transactions on Instrumentation and Measurement.
[33] Yang Weng,et al. Identification of False Data Injection Attacks With Considering the Impact of Wind Generation and Topology Reconfigurations , 2018, IEEE Transactions on Sustainable Energy.
[34] Daqing Hou,et al. Capacitive voltage transformer: transient overreach concerns and solutions for distance relaying , 1996, Proceedings of 1996 Canadian Conference on Electrical and Computer Engineering.
[35] Pradipta Kishore Dash,et al. Distance protection using a time–frequency filtering technique , 2015 .
[36] Dario Petri,et al. Synchrophasor Estimators Accuracy: A Comparative Analysis , 2013, IEEE Transactions on Instrumentation and Measurement.