Five-year Outcomes of Eyes With Glaucoma Drainage Device and Penetrating Keratoplasty

PurposeTo investigate intraocular pressure (IOP) control and corneal graft survival rates in eyes with glaucoma drainage device (GDD) implantation and penetrating keratoplasty (PK) and 5 years of follow-up data. DesignRetrospective review. MethodsWe performed a review of records of all patients who underwent both GDD placement and PK at our institution between January 1, 1988 and December 31, 2003. Twenty-eight eyes of 27 patients were studied. Glaucoma outcome was assessed by postoperative IOP, number of glaucoma medications, and need for further glaucoma surgery. Corneal grafts were assessed for clarity. ResultsAll eyes had GDD placement in the anterior chamber. The mean pre-GDD IOP was 28.8±10.3 mm Hg on a mean of 2.6±0.8 glaucoma medications. At 5-year follow-up, the mean IOP was 13.0±5.9 mm Hg on a mean of 0.9±1.0 glaucoma medications. GDD implantation successfully controlled glaucoma in 96%, 86%, 79%, 75%, and 71% of eyes at 1, 2, 3, 4, and 5 years, respectively. Grafts remained clear in 96%, 82%, 75%, 57%, and 54% of eyes at 1, 2, 3, 4, and 5 years, respectively. Failure of glaucoma outcome or graft survival was associated with prior intraocular surgeries. ConclusionsOur data suggests that GDD placement can provide glaucoma control in a high percentage (71%) of eyes with PK even at 5 years. Furthermore, the success of PK in eyes with GDD remains reasonable (54%) at 5 years. IOP control and graft survival rates are comparable with earlier published studies with shorter follow-up or tube placement in the vitreous cavity.

[1]  A. Coleman,et al.  Graft failure after penetrating keratoplasty in eyes with Ahmed valves. , 2010, American journal of ophthalmology.

[2]  S. Gedde,et al.  Review of results from the Tube Versus Trabeculectomy Study , 2010, Current opinion in ophthalmology.

[3]  M. Conaway,et al.  Long-term Intraocular Pressure Control and Corneal Graft Survival in Eyes With a Pars Plana Baerveldt Implant and Corneal Transplant , 2010, Journal of glaucoma.

[4]  R. Ritch,et al.  Baerveldt Glaucoma Implant in the Ciliary Sulcus: Midterm Follow-up , 2010, Journal of glaucoma.

[5]  R. Beck,et al.  Recipient risk factors for graft failure in the cornea donor study. , 2009, Ophthalmology.

[6]  M. Banitt,et al.  Management of patients with combined glaucoma and corneal transplant surgery , 2009, Eye.

[7]  Marianne O Price,et al.  Corneal Transplant Rejection Rate and Severity After Endothelial Keratoplasty , 2007, Cornea.

[8]  I. Schwab,et al.  The long-term results of keratoplasty in eyes with a glaucoma drainage device. , 2004, American journal of ophthalmology.

[9]  A. Al-Torbak Outcome of Combined Ahmed Glaucoma Valve Implant and Penetrating Keratoplasty in Refractory Congenital Glaucoma With Corneal Opacity , 2004, Cornea.

[10]  A. Al-Torbak Graft Survival and Glaucoma Outcome After Simultaneous Penetrating Keratoplasty and Ahmed Glaucoma Valve Implant , 2003, Cornea.

[11]  W. Feuer,et al.  Corneal graft survival and intraocular pressure control after penetrating keratoplasty and glaucoma drainage device implantation. , 2001, Ophthalmology.

[12]  D. Ritterband,et al.  Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. , 2001, Ophthalmology.

[13]  K. Joos,et al.  Posterior repositioning of glaucoma implants for anterior segment complications. , 2001, Ophthalmology.

[14]  J. M. Taylor,et al.  Long-term results of eyes with penetrating keratoplasty and glaucoma drainage tube implant. , 2001, Ophthalmology.

[15]  R. Ayyala,et al.  Penetrating keratoplasty and glaucoma. , 2000, Survey of ophthalmology.

[16]  D. Hodge,et al.  Ten-year postoperative results of penetrating keratoplasty. , 1998, Ophthalmology.

[17]  U. Rehany,et al.  Implantation of glaucoma drainage implant tube into the ciliary sulcus in patients with corneal transplants. , 1998, Archives of ophthalmology.

[18]  A. Coleman,et al.  Clinical experience with the Ahmed Glaucoma Valve implant in eyes with prior or concurrent penetrating keratoplasties. , 1997, American journal of ophthalmology.

[19]  M. F. Smith,et al.  Comparison of the Baerveldt glaucoma implant with the double-plate Molteno drainage implant. , 1995, Archives of ophthalmology.

[20]  E. Cohen,et al.  Results of Alloplastic Tube Shunt Procedures Before, During, or After Penetrating Keratoplasty , 1995, Cornea.

[21]  D. Minckler,et al.  Initial clinical experience with the baerveldt implant in complicated glaucomas. , 1994, Ophthalmology.

[22]  Doyle Jw,et al.  Glaucoma after penetrating keratoplasty. , 1994, Seminars in ophthalmology.

[23]  M. F. Smith,et al.  Drainage tube implants in the treatment of glaucoma following penetrating keratoplasty. , 1993, Ophthalmic surgery.

[24]  M. F. Smith,et al.  Comparison of the double-plate Molteno drainage implant with the Schocket procedure. , 1992, Archives of ophthalmology.

[25]  L. Ficker,et al.  Risk Factors for the Development of Postkeratoplasty Glaucoma , 1992, Cornea.

[26]  D. Minckler,et al.  Combined Molteno implantation and pars plana vitrectomy for neovascular glaucomas. , 1991, Ophthalmology.

[27]  W. Beebe Management of glaucoma in penetrating keratoplasty patients. , 1991, Refractive & corneal surgery.

[28]  H. Gelender,et al.  The use of Molteno implant and anterior chamber tube shunt to encircling band for the treatment of glaucoma in keratoplasty patients. , 1990, Ophthalmology.

[29]  A. Steele,et al.  The management of post-keratoplasty glaucoma by trabeculectomy , 1989, Eye.

[30]  C. Kirkness,et al.  The use of silicone drainage tubing to control post-keratoplasty glaucoma , 1988, Eye.

[31]  R. E. Smith,et al.  Molteno implant for control of glaucoma in eyes after penetrating keratoplasty. , 1988, Ophthalmology.

[32]  G. Foulks Glaucoma associated with penetrating keratoplasty. , 1987, Ophthalmology.

[33]  H. Kaufman,et al.  A mathematical description of causative factors and prevention of elevated intraocular pressure after keratoplasty. , 1977, Investigative ophthalmology & visual science.

[34]  H. Kaufman,et al.  Intraocular Pressure Following Penetrating Keratoplasty , 1969 .