Comparisons of intraocular lens power calculation methods for eyes with previous myopic laser refractive surgery: Bayesian network meta-analysis

PURPOSE To compare the accuracy of the methods for calculation of intraocular lens (IOL) power in eyes with previous myopic laser refractive surgery. SETTING EENT Hospital of Fudan University, Shanghai, China. DESIGN Network meta-analysis. METHODS A literature search of MEDLINE and Cochrane Library from January 2000 to July 2019 was conducted for studies that evaluated methods of calculating IOL power in eyes with previous myopic laser refractive surgery. Outcomes measurements were the percentages of prediction error within ±0.50 diopters (D) and ±1.00 D of the target refraction (% ±0.50 D and % ±1.00 D). Traditional and network meta-analysis were conducted. RESULTS Nineteen prospective or retrospective clinical studies, including 1217 eyes and 13 calculation methods, were identified. A traditional meta-analysis showed that compared with the widely used Haigis-L method, the Barrett True-K formula, optical coherence tomography (OCT), and Masket methods showed significantly higher % ±0.50 D, whereas no difference was found in the % ±1.00 D. A network meta-analysis revealed that compared with the Haigis-L method, the OCT, Barrett True-K formula, and optiwave refractive analysis (ORA) methods performed better on the % ±0.50 D, whereas the Barrett True-K formula and ORA methods performed better on the % ±1.00 D. Based on the performances of both outcomes, the Barrett True-K formula, OCT, and ORA methods showed highest probability to rank the top 3 among the 13 methods. CONCLUSIONS The Barrett True-K formula, OCT, and ORA methods seemed to offer greater accuracy than others in calculating the IOL power for postrefractive surgery eyes.

[1]  W. Hill,et al.  New algorithm for intraocular lens power calculations after myopic laser in situ keratomileusis based on rotating Scheimpflug camera data , 2015, Journal of cataract and refractive surgery.

[2]  Deborah M Caldwell,et al.  Simultaneous comparison of multiple treatments: combining direct and indirect evidence , 2005, BMJ : British Medical Journal.

[3]  K. Hoffer,et al.  Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery. , 2014, Ophthalmology.

[4]  Frank Krummenauer,et al.  Determination of valid benchmarks for outcome indicators in cataract surgery: a multicenter, prospective cohort trial. , 2011, Ophthalmology.

[5]  Douglas D. Koch,et al.  Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post‐Keratorefractive Intraocular Lens Power Calculator , 2010, Journal of cataract and refractive surgery.

[6]  David Huang,et al.  Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier‐domain optical coherence tomography , 2012, Journal of cataract and refractive surgery.

[7]  Justyna A. Karolak,et al.  IGF-1 gene polymorphisms in Polish families with high-grade myopia , 2011, Molecular vision.

[8]  K. Hoffer Intraocular lens power calculation after previous laser refractive surgery. , 2009, Journal of cataract and refractive surgery.

[9]  D. Koch,et al.  Intraocular Lens Power Calculation in Eyes After Laser In Situ Keratomileusis or Photorefractive Keratectomy for Myopia , 2017, Asia-Pacific journal of ophthalmology.

[10]  Georgia Salanti,et al.  Evaluation of networks of randomized trials , 2008, Statistical methods in medical research.

[11]  H V Gimbel,et al.  Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis , 2001, Journal of cataract and refractive surgery.

[12]  A. Geerards,et al.  Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia. , 2002, Archives of ophthalmology.

[13]  Maya C. Shammas,et al.  No‐history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis , 2007, Journal of cataract and refractive surgery.

[14]  L. G. Pallikaris,et al.  Laser in situ keratomileusis , 1990, Lasers in surgery and medicine.

[15]  G. Savini,et al.  Protocols for studies of intraocular lens formula accuracy. , 2015, American journal of ophthalmology.

[16]  D. Koch,et al.  A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. , 2002, Ophthalmology.

[17]  Yan Li,et al.  High-speed optical coherence tomography of corneal opacities. , 2007, Ophthalmology.

[18]  E. Borasio,et al.  Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula , 2006, Journal of cataract and refractive surgery.

[19]  Donald R. Sanders,et al.  Development of the SRK/T intraocular lens implant power calculation formula , 1990, Journal of cataract and refractive surgery.

[20]  D. Hardten,et al.  Cataract surgery in patients with prior refractive surgery , 2003, Current opinion in ophthalmology.

[21]  Jaime Aramberri,et al.  Intraocular lens power calculation after corneal refractive surgery: Double‐K method , 2003, Journal of cataract and refractive surgery.

[22]  Florence Cabot,et al.  Comparison of IOL power calculation methods and intraoperative wavefront aberrometer in eyes after refractive surgery. , 2013, Journal of refractive surgery.

[23]  D. Koch,et al.  Accuracy of the Barrett True‐K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia , 2016, Journal of cataract and refractive surgery.

[24]  P. Demers,et al.  Photorefractive keratectomy for myopia. , 1996, Ophthalmic surgery and lasers.

[25]  S. Masket,et al.  Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation , 2006, Journal of cataract and refractive surgery.

[26]  Xiaohang Wu,et al.  Meta‐analysis of accuracy of intraocular lens power calculation formulas in short eyes , 2018, Clinical & experimental ophthalmology.

[27]  F. Yuan,et al.  Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes. , 2016, Journal of cataract and refractive surgery.

[28]  D. Koch,et al.  IOL Calculations in Short, Long, and Postrefractive Eyes , 2016, International ophthalmology clinics.

[29]  Ming Wang,et al.  Comparison of intraocular lens power calculation methods after myopic laser refractive surgery without previous refractive surgery data , 2013, Journal of cataract and refractive surgery.

[30]  L. Speicher Intra-ocular lens calculation status after corneal refractive surgery , 2001, Current opinion in ophthalmology.

[31]  M. McKibbin,et al.  Benchmark standards for refractive outcomes after NHS cataract surgery , 2009, Eye.

[32]  Kristian Thorlund,et al.  The PRISMA Extension Statement for Reporting of Systematic Reviews Incorporating Network Meta-analyses of Health Care Interventions: Checklist and Explanations , 2015, Annals of Internal Medicine.

[33]  H. Chu,et al.  Estimating vaccine efficacy using auxiliary outcome data and a small validation sample , 2004, Statistics in medicine.

[34]  M. Mannis,et al.  Intraocular Lens Calculation in a Patient With Previous Penetrating Keratoplasty and LASIK , 2005, Cornea.

[35]  Mitchell P. Weikert,et al.  Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery. , 2015, Ophthalmology.

[36]  R. Liao,et al.  Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery , 2017, BMC Ophthalmology.

[37]  David Huang,et al.  Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis). , 2013, Transactions of the American Ophthalmological Society.

[38]  K. Tsubota,et al.  Modified double‐K method for intraocular lens power calculation after excimer laser corneal refractive surgery , 2013, Journal of cataract and refractive surgery.

[39]  Thomas A Trikalinos,et al.  The appropriateness of asymmetry tests for publication bias in meta-analyses: a large survey , 2007, Canadian Medical Association Journal.

[40]  M. Kim,et al.  Intraocular lens prediction accuracy after corneal refractive surgery using K values from 3 devices , 2013, Journal of cataract and refractive surgery.

[41]  S Dias,et al.  Checking consistency in mixed treatment comparison meta‐analysis , 2010, Statistics in medicine.

[42]  John Ioannidis,et al.  Exploring the Geometry of Treatment Networks , 2008, Annals of Internal Medicine.

[43]  W. Haigis Intraocular lens calculation after refractive surgery for myopia: Haigis‐L formula , 2008, Journal of cataract and refractive surgery.

[44]  D. Koch,et al.  Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. , 2004, Ophthalmology.

[45]  G. Savini,et al.  Intraocular lens power calculation after myopic excimer laser surgery: Selecting the best method using available clinical data , 2015, Journal of cataract and refractive surgery.

[46]  H. Geggel Pachymetric ratio no-history method for intraocular lens power adjustment after excimer laser refractive surgery. , 2009, Ophthalmology.

[47]  Tae-Young Chung,et al.  Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera , 2018, Korean journal of ophthalmology : KJO.

[48]  M. McCarthy,et al.  Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. , 2011, Ophthalmology.

[49]  Joseph C Cappelleri,et al.  Indirect treatment comparison/network meta-analysis study questionnaire to assess relevance and credibility to inform health care decision making: an ISPOR-AMCP-NPC Good Practice Task Force report. , 2014, Value in health : the journal of the International Society for Pharmacoeconomics and Outcomes Research.

[50]  M. Shaheen,et al.  Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis , 2016, Middle East African Journal of Ophthalmology.

[51]  H. Geggel Intraocular Lens Power Adjustment After Myopic Excimer Laser Surgery: Validation Studies for Geggel Ratio and Consensus Group , 2013, Cornea.

[52]  L. Labree,et al.  Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. , 2003, American journal of ophthalmology.