Automatic gas detection in prostate cancer patients during image-guided radiation therapy using a deep convolutional neural network.

PURPOSE The detection of intestinal/rectal gas is very important during image-guided radiation therapy (IGRT) of prostate cancer patients because intestinal/rectal gas increases the inter- and intra-fractional prostate motion. We propose a deep convolutional neural network (DCNN) to detect intestinal/rectal gas in the pelvic region. MATERIAL AND METHODS We selected 300 anterior-posterior kilo-voltage (kV) X-ray images from 30 prostate cancer patients. Thirty images were randomly chosen for a test set, and the remaining 270 images used as the training set. The intestinal/rectal gas was manually delineated on kV X-ray images and segmented. The training images were augmented by applying artificial shifts and fed into a DCNN. The network models were trained to keep the quality of the output image close to the quality of the input image by pooling and upsampling. The training set was used to adjust the parameters of the DCNN, and the test set was used to assess the performance of the model. The performance of the DCNN was evaluated using a fivefold cross-validation procedure. The dice similarity coefficient (DSC) was calculated to evaluate the detection accuracy between the manual contour and auto-segmentation. RESULTS The DCNN was trained within approximately 17 min with a time step of 20 s/epoch. The training and validation accuracy of the models after 50epochs were 0.94 and 0.85, respectively. The average ± standard deviation of the DSC for 30 test images was 0.85 ± 0.08. CONCLUSIONS The proposed DCNN method can automatically detect the intestinal/rectal gas in kV images with good accuracy.

[1]  Hao Chen,et al.  3D deeply supervised network for automated segmentation of volumetric medical images , 2017, Medical Image Anal..

[2]  G Morton,et al.  Target position variability throughout prostate radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[3]  Y. Yamada,et al.  Incidence of late rectal and urinary toxicities after three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for localized prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[4]  Hiram Gay,et al.  Continued Benefit to Rectal Separation for Prostate Radiation Therapy: Final Results of a Phase III Trial. , 2017, International journal of radiation oncology, biology, physics.

[5]  A. Kotte,et al.  Effect of magnesium oxide on interfraction prostate motion and rectal filling in prostate cancer radiotherapy , 2014, Strahlentherapie und Onkologie.

[6]  E. Furhang,et al.  2D kV orthogonal imaging with fiducial markers is more precise for daily image guided alignments than soft-tissue cone beam computed tomography for prostate radiation therapy , 2017, Advances in radiation oncology.

[7]  Lei Dong,et al.  Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[8]  Alex Lallement,et al.  Survey on deep learning for radiotherapy , 2018, Comput. Biol. Medicine.

[9]  M. Hoogeman,et al.  Increased risk of biochemical and clinical failure for prostate patients with a large rectum at radiotherapy planning: results from the Dutch trial of 68 GY versus 78 Gy. , 2007, International journal of radiation oncology, biology, physics.

[10]  C. V. van Gils,et al.  Erratum to: Effect of magnesium oxide on interfraction prostate motion and rectal filling in prostate cancer radiotherapy: analysis of a randomized clinical trial , 2014, Strahlentherapie und Onkologie.

[11]  C. Deville,et al.  The impact of stool and gas volume on intrafraction prostate motion in patients undergoing radiotherapy with daily endorectal balloon. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  P. Lambin,et al.  Dynamics of rectal balloon implant shrinkage in prostate VMAT , 2017, Strahlentherapie und Onkologie.

[13]  C. Maurer,et al.  The CyberKnife® Robotic Radiosurgery System in 2010 , 2010, Technology in cancer research & treatment.

[14]  J Alfred Witjes,et al.  The effect of an endorectal balloon and off-line correction on the interfraction systematic and random prostate position variations: a comparative study. , 2005, International journal of radiation oncology, biology, physics.

[15]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[16]  Qiuwen Wu,et al.  Inferences about prostate intrafraction motion from pre- and posttreatment volumetric imaging. , 2009, International journal of radiation oncology, biology, physics.

[17]  Konstantinos Kamnitsas,et al.  Efficient multi‐scale 3D CNN with fully connected CRF for accurate brain lesion segmentation , 2016, Medical Image Anal..

[18]  Radhe Mohan,et al.  Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[19]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[20]  J. Petersen,et al.  Impact of bowel gas and body outline variations on total accumulated dose with intensity-modulated proton therapy in locally advanced cervical cancer patients , 2017, Acta oncologica.

[21]  Jiazhou Wang,et al.  Technical Note: A deep learning‐based autosegmentation of rectal tumors in MR images , 2018, Medical physics.

[22]  J. Galvin,et al.  Preliminary toxicity analysis of 3-dimensional conformal radiation therapy versus intensity modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group 0126 prostate cancer trial. , 2013, International journal of radiation oncology, biology, physics.

[23]  David Gillatt,et al.  10-Year Outcomes after Monitoring, Surgery, or Radiotherapy for Localized Prostate Cancer. , 2017, The New England journal of medicine.

[24]  Kuo Men,et al.  Automatic segmentation of the clinical target volume and organs at risk in the planning CT for rectal cancer using deep dilated convolutional neural networks , 2017, Medical physics.

[25]  Bulat Ibragimov,et al.  Segmentation of organs‐at‐risks in head and neck CT images using convolutional neural networks , 2017, Medical physics.

[26]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[27]  Geoffrey E. Hinton,et al.  Deep Learning , 2015, Nature.

[28]  J. Lebesque,et al.  Update of Dutch multicenter dose-escalation trial of radiotherapy for localized prostate cancer. , 2008, International journal of radiation oncology, biology, physics.

[29]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[30]  J C Stroom,et al.  Detection of internal organ movement in prostate cancer patients using portal images. , 2000, Medical physics.

[31]  C. Pelizzari,et al.  Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. , 1995, International journal of radiation oncology, biology, physics.