Neuromuscular stimulation in spinal cord injury: I: Restoration of functional movement of the extremities.

The spinal cord injured patient has been the focus of clinical and research efforts to restore functional movement and obtain therapeutic benefits by electric stimulation of upper-motor-neuron paralyzed muscles. Our review articles treat developments in this field from 1983 to 1990. Efforts have been directed to restoring hand function, standing, and walking (covered in part I), as well as prevention of secondary complications through ventilatory function, bladder function, and achieving therapeutic effects of electric stimulation (covered in Part II). The technology for hand function, standing, and walking is used primarily in the research laboratory, as clinical applications are minimal. Much work remains to be done to solve the difficult problems associated with applying this promising technology to spinal cord injury.

[1]  Long C nd AN ELECTROPHYSIOLOGIC SPLINT FOR THE HAND. , 1963 .

[2]  Cooper Eb,et al.  Effects of chronic human neuromuscular stimulation. , 1973 .

[3]  U Stanic,et al.  Closed-loop positioning of hemiplegic patient's joint by means of functional electrical stimulation. , 1974, IEEE transactions on bio-medical engineering.

[4]  L Vodovnik,et al.  Information content of myo-control signals for orthotic and prosthetic systems. , 1974, Archives of physical medicine and rehabilitation.

[5]  C. W. Caldwell,et al.  A Percutaneous Wire Electrode for Chronic Research Use , 1975, IEEE Transactions on Biomedical Engineering.

[6]  Bates Ja Therapeutic electrical stimulation. The transistorized placebo , 1978 .

[7]  R. Edwards,et al.  Physiological analysis of skeletal muscle weakness and fatigue. , 1978, Clinical science and molecular medicine.

[8]  D. Rushton,et al.  Electrical splinting of the knee in paraplegia , 1979, Paraplegia.

[9]  A. McGeorge,et al.  Contemporary Clinical Neurophysiology , 1979 .

[10]  B. Bigland-ritchie,et al.  Excitation frequency and muscle fatigue: Mechanical responses during voluntary and stimulated contractions , 1979, Experimental Neurology.

[11]  E. Marsolais,et al.  Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation. , 1980 .

[12]  T Bajd,et al.  Functional electrical stimulation for control of locomotor systems. , 1981, Critical reviews in bioengineering.

[13]  T Bajd,et al.  Standing-up of a healthy subject and a paraplegic patient. , 1982, Journal of biomechanics.

[14]  E. Marsolais,et al.  Functional walking in paralyzed patients by means of electrical stimulation. , 1983, Clinical orthopaedics and related research.

[15]  T. Bajd,et al.  The use of a four-channel electrical stimulator as an ambulatory aid for paraplegic patients. , 1983, Physical therapy.

[16]  J. Kiwerski,et al.  Electrostimulation of the median nerve in tetraplegics by means of implanted stimulators , 1979, Paraplegia.

[17]  R. Douglas,et al.  The LSU Reciprocation-Gait Orthosis. , 1983, Orthopedics.

[18]  R. Nathan The development of a computerized upper limb electrical stimulation system. , 1984, Orthopedics.

[19]  Histopathological evaluation of dog sacral nerve after chronic electrical stimulation for micturition. , 1984 .

[20]  R. Penn,et al.  Lower Extremity Functional Neuromuscular Stimulation in Cases of Spinal Cord Injury , 1984, Neurosurgery.

[21]  K F Eichhorn,et al.  Maintenance, training and functional use of denervated muscles. , 1984, Journal of biomedical engineering.

[22]  H Thoma,et al.  Functional electrostimulation of paraplegics: experimental investigations and first clinical experience with an implantable stimulation device. , 1984, Orthopedics.

[23]  A. Upton,et al.  Neurostimulation: An Overview , 1985 .

[24]  R. Waters,et al.  Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up. , 1985, The Journal of bone and joint surgery. American volume.

[25]  R. Waters,et al.  Energy cost of paraplegic locomotion. , 1985, The Journal of bone and joint surgery. American volume.

[26]  L. Vodovnik,et al.  Change in muscle force following electrical stimulation. Dependence on stimulation waveform and frequency. , 1985, Scandinavian journal of rehabilitation medicine.

[27]  Howard J. Chizeck,et al.  Design and Evaluation of a Digital Closed-Loop Controller for the Regulation of Muscle Force by Recruitment Modulation , 1985, IEEE Transactions on Biomedical Engineering.

[28]  A. Heinemann,et al.  Evaluating the special needs of functional neuromuscular stimulation research candidates. , 1985, Journal of medical engineering & technology.

[29]  J Mizrahi,et al.  Activation of paraplegic patients by functional electrical stimulation: training and biomechanical evaluation. , 1985, Scandinavian journal of rehabilitation medicine. Supplement.

[30]  J S Petrofsky,et al.  Closed-loop control of movement of skeletal muscle. , 1985, Critical reviews in biomedical engineering.

[31]  E. Marsolais,et al.  Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities. , 1986, Journal of rehabilitation research and development.

[32]  T. Bajd,et al.  Posture switching for prolonging functional electrical stimulation standing in paraplegic patients , 1986, Paraplegia.

[33]  R J Jaeger Design and simulation of closed-loop electrical stimulation orthoses for restoration of quiet standing in paraplegia. , 1986, Journal of biomechanics.

[34]  Chandler A. Phillips,et al.  A Computer-Controlled Walking System: The Combination Of An Orthosis With Functional Electrical Stimulation , 1986 .

[35]  Michael R. Neuman,et al.  Sensors for Use with Functional Neuromuscular Stimulation , 1986, IEEE Transactions on Biomedical Engineering.

[36]  L. A. Bernotas,et al.  Adaptive Control of Electrically Stimulated Muscle , 1987, IEEE Transactions on Biomedical Engineering.

[37]  E. Marsolais,et al.  Functional electrical stimulation for walking in paraplegia. , 1987, The Journal of bone and joint surgery. American volume.

[38]  N. Hoshimiya,et al.  Functional electrical stimulation for the control of the upper extremities. , 1987, Medical progress through technology.

[39]  B. Andrews,et al.  Augmentation of the Oswestry Parawalker orthosis by means of surface electrical stimulation: gait analysis of three patients , 1987, Paraplegia.

[40]  P. Peckham Functional electrical stimulation: current status and future prospects of applications to the neuromuscular system in spinal cord injury , 1987, Paraplegia.

[41]  A. Heinemann,et al.  Mobility for persons with spinal cord injury: an evaluation of two systems. , 1987, Archives of physical medicine and rehabilitation.

[42]  Helping the paraplegic to walk. , 1987, The Journal of bone and joint surgery. British volume.

[43]  P. Donaldson,et al.  Twenty years of neurological prosthesis-making. , 1987, Journal of biomedical engineering.

[44]  Fatehi Mt,et al.  Burns in functional electric stimulation: two case reports. , 1987 .

[45]  C A Phillips,et al.  Sensory feedback control of upper- and lower-extremity motor prostheses. , 1988, Critical reviews in biomedical engineering.

[46]  D. Mcneal,et al.  Effects of waveform on comfort during neuromuscular electrical stimulation. , 1988, Clinical orthopaedics and related research.

[47]  E. B. Marsolais,et al.  Control of functional neuromuscular stimulation systems for standing and locomotion in paraplegics , 1988, Proc. IEEE.

[48]  D J Ewins,et al.  Practical low cost stand/sit system for mid-thoracic paraplegics. , 1988, Journal of biomedical engineering.

[49]  J P Paul,et al.  Hybrid FES orthosis incorporating closed loop control and sensory feedback. , 1988, Journal of biomedical engineering.

[50]  E. Marsolais,et al.  Energy costs of walking and standing with functional neuromuscular stimulation and long leg braces. , 1988, Archives of physical medicine and rehabilitation.

[51]  E. Marsolais,et al.  Development of a practical electrical stimulation system for restoring gait in the paralyzed patient. , 1988, Clinical orthopaedics and related research.

[52]  P.H. Peckham,et al.  A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity , 1988, IEEE Transactions on Biomedical Engineering.

[53]  P. H. Peckham,et al.  Restoration of functional control by electrical stimulation in the upper extremity of the quadriplegic patient. , 1988, The Journal of bone and joint surgery. American volume.

[54]  M. Keith,et al.  Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand. , 1988, Clinical orthopaedics and related research.

[55]  J P Paul,et al.  Reduction of muscle fatigue in man by cyclical stimulation. , 1988, Journal of biomedical engineering.

[56]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[57]  W. J. Heetderks,et al.  Applied neural control in the 1990s , 1988, Proc. IEEE.

[58]  D.R. McNeal,et al.  Recruitment data for nerve cuff electrodes: implications for design of implantable stimulators , 1989, IEEE Transactions on Biomedical Engineering.

[59]  A. Kralj,et al.  Functional Electrical Stimulation: Standing and Walking after Spinal Cord Injury , 1989 .

[60]  G. Vrbóva,et al.  Neuromuscular stimulation : basic concepts and clinical implications , 1989 .

[61]  R J Jaeger,et al.  Rehabilitation Technology for Standing and Walking after Spinal Cord Injury , 1989, American journal of physical medicine & rehabilitation.

[62]  D.R. McNeal,et al.  Open-loop control of the freely-swinging paralyzed leg , 1989, IEEE Transactions on Biomedical Engineering.

[63]  L. Schwirtlich,et al.  Hybrid assistive system-the motor neuroprosthesis , 1989, IEEE Transactions on Biomedical Engineering.

[64]  N. Hoshimiya,et al.  Development of percutaneous intramuscular electrode for multichannel FES system , 1989, IEEE Transactions on Biomedical Engineering.

[65]  W. Mayr,et al.  Technology and long-term application of an epineural electrode. , 1989, ASAIO transactions.

[66]  R. D'ambrosia,et al.  The RGO Generation II: muscle stimulation powered orthosis as a practical walking system for thoracic paraplegics. , 1989, Orthopedics.

[67]  C. Phillips Functional electrical stimulation and lower extremity bracing for ambulation exercise of the spinal cord injured individual: a medically prescribed system. , 1989, Physical therapy.

[68]  P.H. Peckham,et al.  Elbow extension in the C5 quadriplegic using functional neuromuscular stimulation , 1989, IEEE Transactions on Biomedical Engineering.

[69]  D. Graupe EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking , 1989, IEEE Transactions on Biomedical Engineering.

[70]  F.E. Zajac,et al.  Paraplegic standing controlled by functional neuromuscular stimulation. I. Computer model and control-system design , 1989, IEEE Transactions on Biomedical Engineering.

[71]  A. Nene,et al.  Hybrid paraplegic locomotion with the ParaWalker using intramuscular stimulation: a single subject study , 1989, Paraplegia.

[72]  F. Zajac,et al.  Paraplegic standing controlled by functional neuromuscular stimulation. II. Computer simulation studies , 1989, IEEE Transactions on Biomedical Engineering.

[73]  K. Kilgore,et al.  Implantable functional neuromuscular stimulation in the tetraplegic hand. , 1989, The Journal of hand surgery.

[74]  K.L. Kilgore,et al.  Synthesis of hand grasp using functional neuromuscular stimulation , 1989, IEEE Transactions on Biomedical Engineering.

[75]  J. Kawamura,et al.  Functional neuromuscular stimulation system using an implantable hydroxyapatite connector and a microprocessor-based portable stimulator , 1989, IEEE Transactions on Biomedical Engineering.

[76]  G. Yarkony,et al.  Standing the spinal cord injured patient by electrical stimulation: refinement of a protocol for clinical use , 1989, IEEE Transactions on Biomedical Engineering.

[77]  N. Hoshimiya,et al.  A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity , 1989, IEEE Transactions on Biomedical Engineering.

[78]  F.E. Zajac,et al.  Restoring unassisted natural gait to paraplegics via functional neuromuscular stimulation: a computer simulation study , 1990, IEEE Transactions on Biomedical Engineering.

[79]  D. A. Ksienski,et al.  A nerve cuff technique for selective excitation of peripheral nerve trunk regions , 1990, IEEE Transactions on Biomedical Engineering.

[80]  R P Patterson,et al.  A functional electric stimulation system using an electrode garment. , 1990, Archives of physical medicine and rehabilitation.

[81]  R. Nathan,et al.  Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. , 1990, Archives of physical medicine and rehabilitation.

[82]  R. D'ambrosia,et al.  Energy consumption in paraplegic ambulation using the reciprocating gait orthosis and electric stimulation of the thigh muscles. , 1990, Archives of physical medicine and rehabilitation.

[83]  D. McCreery,et al.  Neural prostheses : fundamental studies , 1990 .

[84]  E. Roth,et al.  Estimating the user population of a simple electrical stimulation system for standing , 1990, Paraplegia.

[85]  M. Keith,et al.  Functional evaluation of quadriplegic patients using a hand neuroprosthesis. , 1990, Archives of physical medicine and rehabilitation.