Design and Calibration of the Unilateral Sensitive Soil Moisture Sensor

Reliable and affordable moisture sensors with a simplified calibration process for obtaining the water content information of soil/soilless substrates were limited. In this paper, an unilateral sensitive capacitive soil moisture sensor, based on the improved ECH2O sensor probe structure, was presented. Through simulating the relationship between the ratio of plate space and plate width (a/b) and probe sensitivity, sensitive depth, respectively, the size of the sensor was determined with ANSYS first. Capacitance measurement circuit based on resonant principle was then designed. The relationship between the output of the sensor and the soil water content calibration model (β parameter model), was investigated. As a result, we proposed a two-step calibration β method. Experimental results showed that β parameter model appropriately described the relationship between the output and the soil water content, the minimum correlation coefficient R2 = 0.9554 in the soil, peat, perlite, and vinegar residue. The measurement error of β parameter model was <;0.025 units except in perlite. The error caused by the change of bulk density was <;0.025 units in peat and vinegar residue. Therefore, the two-step calibration β method is suitable for calibrating the sensor.

[1]  A. P. Annan,et al.  Electromagnetic determination of soil water content: Measurements in coaxial transmission lines , 1980 .

[2]  E. Kudryashov,et al.  Experimental study on a planar capacitative displacement sensor , 1995 .

[3]  G. Liang,et al.  Study on epoxy matrix modified with poly(2,6-dimethyl-1,4-phenylene ether) for application to copper clad laminate , 2002 .

[4]  S. Jones,et al.  A Review of Advances in Dielectric and Electrical Conductivity Measurement in Soils Using Time Domain Reflectometry , 2003 .

[5]  Martin Bachmaier,et al.  Field calibration of a capacitance soil water probe in heterogeneous fields , 2004 .

[6]  Scott B. Jones,et al.  Standardizing Characterization of Electromagnetic Water Content Sensors: Part 1. Methodology , 2005 .

[7]  Jan M. H. Hendrickx,et al.  Methods for prediction of soil dielectric properties: a review , 2005, SPIE Defense + Commercial Sensing.

[8]  R. C. Derksen,et al.  STATISTICAL EVALUATION OF INSTRUMENTS DESIGNED TO MEASURE VOLUMETRIC WATER CONTENT OF SOILLESS CONTAINER MEDIA , 2006 .

[9]  Francesco Montesano,et al.  Calibration and performance of moisture sensors in soilless substrates: ECH2O and Theta probes , 2007 .

[10]  Dana Porter,et al.  Irrigation Monitoring with Soil Water Sensors , 2007 .

[11]  H. Vereecken,et al.  Evaluation of a low-cost soil water content sensor for wireless network applications , 2007 .

[12]  J. Vrugt,et al.  On the value of soil moisture measurements in vadose zone hydrology: A review , 2008 .

[13]  Jan W. Hopmans,et al.  Frequency, electrical conductivity and temperature analysis of a low-cost capacitance soil moisture sensor , 2008 .

[14]  Tissa H. Illangasekare,et al.  Empirical two‐point α‐mixing model for calibrating the ECH2O EC‐5 soil moisture sensor in sands , 2008 .

[15]  Pedro Sánchez,et al.  Wireless Sensor Networks for precision horticulture in Southern Spain , 2009 .

[16]  Experimental quantification of bulk sampling volume of ECH2O soil moisture sensors , 2009 .

[17]  M. Safeeq,et al.  Adjusting Temperature and Salinity Effects on Single Capacitance Sensors , 2009 .

[18]  M. Helmers,et al.  The conversion of permittivity as measured by a PR2 capacitance probe into soil moisture values for Des Moines lobe soils in Iowa , 2010 .

[19]  Harry Vereecken,et al.  Sensor‐to‐Sensor Variability of the ECH2O EC‐5, TE, and 5TE Sensors in Dielectric Liquids , 2010 .

[20]  H. Vereecken,et al.  Potential of Wireless Sensor Networks for Measuring Soil Water Content Variability , 2010 .

[21]  T. Illangasekare,et al.  A Simple Method for Calibrating Dielectric Soil Moisture Sensors: Laboratory Validation in Sands , 2011 .

[22]  Gang Wang,et al.  The relationship between electrical capacitance-based dielectric constant and soil water content , 2011 .

[23]  M. Suso,et al.  USE OF SOIL MOISTURE SENSORS FOR AUTOMATIC HIGH FREQUENCY DRIP IRRIGATION IN PROCESSING TOMATO , 2011 .

[24]  F. Francisca,et al.  Measuring the dielectric properties of soil–organic mixtures using coaxial impedance dielectric reflectometry , 2012 .

[25]  Sonia I. Seneviratne,et al.  Comparison of four soil moisture sensor types under field conditions in Switzerland , 2012 .

[26]  Michael D. Dukes,et al.  Soil Moisture Sensor Landscape Irrigation Controllers: A Review of Multi-Study Results and Future Implications , 2012 .

[27]  Mingyan Liu,et al.  In-situ soil moisture sensing , 2012, ACM Trans. Sens. Networks.

[28]  Konstantinos X. Soulis,et al.  Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor , 2012 .

[29]  Pariva Dobriyal,et al.  A review of the methods available for estimating soil moisture and its implications for water resource management , 2012 .

[30]  陈谦,et al.  Capacitive soil moisture sensor , 2014 .

[31]  Nunzio Romano,et al.  Soil moisture at local scale: Measurements and simulations , 2014 .

[32]  M. Baghini,et al.  A critical review of soil moisture measurement , 2014 .