In-Fiber Fabry–Perot and Mach–Zehnder interferometers based on hollow optical fiber fabricated by arc fusion splicing with small lateral offsets

Abstract Two kinds of in-line all-fiber interferometers, including tip Fabry–Perot interferometer and compact Mach–Zehnder interferometer, are proposed and demonstrated by fusion splicing a short section of hollow optical fiber (HOF) to the end of single-mode fiber (SMF) and sandwiching a section of HOF in between two sections of SMF, respectively. In both interferometers, a small lateral offset is introduced to induce the optical path difference required to form the interferometer. Temperature responses of both types of interferometers are studied experimentally. It is anticipated that such easy making, compact and low-cost fiber-optic interferometers could find important applications in practice.

[1]  James S. Sirkis,et al.  In-line fiber etalon (ILFE) fiber-optic strain sensors , 1995 .

[2]  Ik-Bu Sohn,et al.  Ultracompact Intrinsic Micro Air-Cavity Fiber Mach–Zehnder Interferometer , 2009, IEEE Photonics Technology Letters.

[3]  Bong-Ahn Yu,et al.  Highly sensitive strain and bending sensor based on in-line fiber Mach–Zehnder interferometer in solid core large mode area photonic crystal fiber , 2010 .

[4]  Byeong Ha Lee,et al.  Ultracompact in-line broadband Mach-Zehnder interferometer using a composite leaky hollow-optical-fiber waveguide. , 2008, Optics letters.

[5]  H. Choi,et al.  All-fiber Mach-Zehnder type interferometers formed in photonic crystal fiber. , 2007, Optics express.

[6]  P. Lu,et al.  Fiber in-line Mach-Zehnder interferometer fabricated by femtosecond laser micromachining for refractive index measurement with high sensitivity , 2010 .

[7]  Kwan Seob Park,et al.  Miniature fiber-optic high temperature sensor based on a hybrid structured Fabry-Perot interferometer. , 2008, Optics letters.

[8]  Zhaobing Tian,et al.  In-Line Single-Mode Optical Fiber Interferometric Refractive Index Sensors , 2009, Journal of Lightwave Technology.

[9]  Marc Douay,et al.  Study of in fiber Mach–Zehnder interferometer based on two spaced 3-dB long period gratings surrounded by a refractive index higher than that of silica , 2000 .

[10]  Yunjiang Rao,et al.  Fabry–Perot optical fiber tip sensor for high temperature measurement , 2010 .

[11]  Henry F. Taylor,et al.  In-line fiber Fabry-Perot interferometer with high-reflectance internal mirrors , 1992 .

[12]  Mach-Zehnder interferometer based on core-cladding mode coupling in single mode fibers , 2010 .

[13]  Stephen F Collins,et al.  Intrinsic fibre Fabry-Perot sensors based on co-located Bragg gratings , 1997 .

[14]  Sumei Wang,et al.  Ultra-Abrupt Tapered Fiber Mach-Zehnder Interferometer Sensors , 2011, Sensors.

[15]  J. S. Sirkis,et al.  Simultaneously measuring temperature and strain using optical fiber microcavities , 1997 .

[16]  J. P. Carvalho,et al.  Modal interferometer based on hollow-core photonic crystal fiber for strain and temperature measurement. , 2009, Optics express.

[17]  Y. Rao Recent progress in fiber-optic extrinsic Fabry–Perot interferometric sensors , 2006 .

[18]  J S Sirkis,et al.  In-line fiber étalon for strain measurement. , 1993, Optics letters.

[19]  Y. Rao,et al.  In-line fiber-optic etalon formed by hollow-core photonic crystal fiber , 2007, 2007 Asia Optical Fiber Communication and Optoelectronics Conference.