An improved Doppler model for obtaining accurate maximum blood velocities.

Maximum blood velocity estimates are frequently required in diagnostic applications, including carotid stenosis evaluation, arteriovenous fistula inspection, and maternal-fetal examinations. However, the currently used methods for ultrasound measurements are inaccurate and often rely on applying heuristic thresholds to a Doppler power spectrum. A new method that uses a mathematical model to predict the correct threshold that should be used for maximum velocity measurements has recently been introduced. Although it is a valuable and deterministic tool, this method is limited to parabolic flows insonated by uniform pressure fields. In this work, a more generalized technique that overcomes such limitations is presented. The new approach, which uses an extended Doppler spectrum model, has been implemented in an experimental set-up based on a linear array probe that transmits defocused steered waves. The improved model has been validated by Field II simulations and phantom experiments on tubes with diameters between 2mm and 8mm. Using the spectral threshold suggested by the new model significantly higher accuracy estimates of the peak velocity can be achieved than are now clinically attained, including for narrow beams and non-parabolic velocity profiles. In particular, an accuracy of +1.2±2.5 cm/s has been obtained in phantom measurements for velocities ranging from 20 to 80 cm/s. This result represents an improvement that can significantly affect the way maximum blood velocity is investigated today.

[1]  K V Ramnarine,et al.  Validation of a new blood-mimicking fluid for use in Doppler flow test objects. , 1998, Ultrasound in medicine & biology.

[2]  R S Cobbold,et al.  Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow. , 2001, Ultrasound in medicine & biology.

[3]  Helena Gardiner,et al.  Volume blood flow estimation in the normal and growth-restricted fetus. , 2002, Ultrasound in medicine & biology.

[4]  P. Tortoli,et al.  Multichannel FPGA-based arbitrary waveform generator for medical ultrasound , 2007 .

[5]  D. Steinman,et al.  Effect of velocity profile skewing on blood velocity and volume flow waveforms derived from maximum Doppler spectral velocity. , 2013, Ultrasound in medicine & biology.

[6]  K. Johnston,et al.  Interobserver variability of carotid Doppler peak velocity measurements among technologists in an ICAVL-accredited vascular laboratory. , 2004, Journal of vascular surgery.

[7]  S. Ricci,et al.  Adaptive spectral estimators for fast flow-profile detection , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Erik Buskens,et al.  Optimal peak systolic velocity threshold at duplex us for determining the need for carotid endarterectomy: a decision analytic approach. , 2006, Radiology.

[9]  G. Aldis,et al.  Spectral power density calculations for pulsed Doppler. , 2002, Ultrasonics.

[10]  A. Hughes,et al.  Reproducibility Study of Magnetic Resonance Image-Based Computational Fluid Dynamics Prediction of Carotid Bifurcation Flow , 2003, Annals of Biomedical Engineering.

[11]  Piero Tortoli,et al.  Finding the peak velocity in a flow from its doppler spectrum , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[14]  P. Tortoli,et al.  Improved blood velocity estimation using the maximum Doppler frequency. , 1995, Ultrasound in medicine & biology.

[15]  Piero Tortoli,et al.  Intraluminal ultrasound intensity distribution and backscattered Doppler power. , 2004, Ultrasound in medicine & biology.

[16]  A. Nowicki,et al.  Comparison of the performance of three maximum Doppler frequency estimators coupled with different spectral estimation methods. , 1994, Ultrasound in medicine & biology.

[17]  Richard S C Cobbold,et al.  Human factors as a source of error in peak Doppler velocity measurement. , 2005, Journal of vascular surgery.

[18]  Pascal Verdonck,et al.  The Accuracy of Ultrasound Volume Flow Measurements in the Complex Flow Setting of a Forearm Vascular Access , 2013, The journal of vascular access.

[19]  S. Diciotti,et al.  Accuracy and reproducibility of a novel dual-beam vector Doppler method. , 2009, Ultrasound in medicine & biology.

[20]  P. Fish,et al.  Doppler power spectrum from a Gaussian sample volume. , 2000, Ultrasonics.

[21]  W. McDicken,et al.  Doppler Ultrasound: Physics, Instrumentation and Signal Processing , 2000 .

[22]  David A Steinman,et al.  Errors in the estimation of wall shear stress by maximum Doppler velocity. , 2013, Atherosclerosis.

[23]  H. Torp,et al.  Simultaneous quantification of flow and tissue velocities based on multi-angle plane wave imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Cinoo Kim,et al.  Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. , 2007, British journal of anaesthesia.

[25]  Piero Tortoli,et al.  Real-time vector velocity assessment through multigate doppler and plane waves , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  A. Dallai,et al.  ULA-OP: an advanced open platform for ultrasound research , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  L. William Varner,et al.  Geometrical Spectrum Broadening in Ultrasonic Doppler Systems , 1977, IEEE Transactions on Biomedical Engineering.

[28]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  A. Dallai,et al.  A reconfigurable and programmable FPGA-based system for nonstandard ultrasound methods , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  R Eugene Zierler,et al.  Carotid artery stenosis: gray-scale and Doppler US diagnosis--Society of Radiologists in Ultrasound Consensus Conference. , 2003, Radiology.

[31]  Piero Tortoli,et al.  Accuracy and reproducibility of a novel dynamic volume flow measurement method. , 2013, Ultrasound in medicine & biology.

[32]  Piero Tortoli,et al.  Embedded Doppler system for industrial in-line rheometry , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.