A Second-Generation, Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms

BACKGROUND AND PURPOSE: We report a preclinical study of a second-generation endoluminal device (Pipeline Embolization Device [PED-2] for aneurysmal occlusion and compare the PED-2 with its first-generation predecessor (PED-1). MATERIALS AND METHODS: Our Institutional Animal Care and Use Committee approved all studies. The PED-2 is a braided endoluminal, flow-diverting device and was implanted across the necks of 18 elastase-induced aneurysms in New Zealand white rabbits and followed for 1 month (n = 6), 3 months (n = 6), and 6 months (n = 6). A second PED-2 was implanted in the abdominal aorta to cover the origins of the lumbar arteries. Angiographic occlusion rates were documented as complete, near-complete, and incomplete. Parent artery percent diameter stenosis was calculated. Results were compared with a previous publication focused on the PED-1, with use of the same model. We compared ordinal outcomes using Fisher Exact or χ2 tests. We compared continuous data using analysis of variance. RESULTS: Occlusion rates (complete and incomplete) for the PED-2 were noted in 17 cases (94%) and 1 (6%), respectively, compared with 9 cases of complete (53%) and 8 (47%) of incomplete occlusion with the PED-1 (P = .0072). No incidents of branch artery occlusion or distal emboli in vessels downstream of the parent artery were observed with the PED-2. Parent artery neointimal hyperplasia was minimal in most cases and was significantly less than in the PED-1. CONCLUSIONS: The PED-2 is a biocompatible and hemocompatible device that occludes saccular aneurysms while preserving the parent artery and small-branch vessels in our animal model.

[1]  E. Vicaut,et al.  Endovascular treatment of basilar tip aneurysms with Guglielmi detachable coils: predictors of immediate and long-term results with multivariate analysis 6-year experience. , 2003, Radiology.

[2]  David F. Kallmes,et al.  A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms , 2007, Stroke.

[3]  R. Virmani,et al.  Drug eluting stents: are human and animal studies comparable? , 2003, Heart.

[4]  D. Fiorella,et al.  Balloon-in-Stent Technique for the Constructive Endovascular Treatment of “Ultra-Wide Necked” Circumferential Aneurysms , 2005, Neurosurgery.

[5]  H. Cloft HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: periprocedural results. , 2006, AJNR. American journal of neuroradiology.

[6]  D. Kallmes,et al.  Modified histologic technique for processing metallic coil-bearing tissue. , 2005, AJNR. American journal of neuroradiology.

[7]  M. Hori,et al.  Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up. , 1998, Circulation.

[8]  R E Vlietstra,et al.  Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. , 1992, Journal of the American College of Cardiology.

[9]  R. Virmani,et al.  Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding nitinol stent in an experimental model. , 1998, Catheterization and cardiovascular diagnosis.

[10]  Liliana Cesar,et al.  An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms: Evaluation in the Rabbit Elastase-Induced Model , 2009, Stroke.

[11]  P. Sandercock,et al.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion , 2005, The Lancet.

[12]  T. Itakura,et al.  Study of the patency of small arterial branches after stent placement with an experimental in vivo model. , 2002, AJNR. American journal of neuroradiology.

[13]  H. Cloft HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: 3-6 month angiographic follow-up results. , 2007, AJNR. American journal of neuroradiology.

[14]  I. Saatci,et al.  Treatment of internal carotid artery aneurysms with a covered stent: experience in 24 patients with mid-term follow-up results. , 2004, AJNR. American journal of neuroradiology.

[15]  Alejandro Berenstein,et al.  Endosaccular Treatment of Intracranial Aneurysms Using Matrix Coils: Early Experience and Midterm Follow-Up , 2006, Stroke.

[16]  T A Altes,et al.  1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: a model suitable for testing endovascular devices. American Roentgen Ray Society. , 2000, AJR. American journal of roentgenology.

[17]  David F. Kallmes,et al.  Creation of Saccular Aneurysms in the Rabbit , 2000 .

[18]  J. Ausman,et al.  The remodeling technique of balloon-assisted Guglielmi detachable coil placement in wide-necked aneurysms: experience at the University of Illinois at Chicago. , 2000, Journal of neurosurgery.

[19]  Bernd F. M. Romeike,et al.  Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device , 2007, Neuroradiology.