The Forensic Reference Phantom—a new tool for quality assurance of attenuation measurements in forensic radiology

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

[1]  Michael J. Thali,et al.  The rise of forensic and post-mortem radiology—Analysis of the literature between the year 2000 and 2011 , 2013 .

[2]  W. Kalender,et al.  The European Spine Phantom--a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. , 1995, European journal of radiology.

[3]  C. Jackowski,et al.  Extended CT Scale Overcomes Restoration Caused Streak Artifacts for Dental Identification in CT - 3D Color Encoded Automatic Discrimination of Dental Restorations , 2006, Journal of computer assisted tomography.

[4]  Michael J Thali,et al.  Detection of smuggled cocaine in cargo using MDCT. , 2008, AJR. American journal of roentgenology.

[5]  Tobias Rudolph,et al.  CT data-based navigation for post-mortem biopsy--a feasibility study. , 2008, Journal of forensic and legal medicine.

[6]  Material differentiation in forensic radiology with single-source dual-energy computed tomography , 2013, Forensic Science, Medicine, and Pathology.

[7]  Death by biscuit--exhumation, post-mortem CT, and revision of the cause of death one year after interment. , 2011, Legal medicine.

[8]  B. Yeh,et al.  Dual-energy and low-kVp CT in the abdomen. , 2009, AJR. American journal of roentgenology.

[9]  K. Stierstorfer,et al.  Image reconstruction and image quality evaluation for a dual source CT scanner. , 2003, Medical physics.

[10]  A. Persson,et al.  Fire victim identification by post-mortem dental CT: radiologic evaluation of restorative materials after exposure to high temperatures. , 2011, European journal of radiology.

[11]  W. Huda,et al.  Review of Radiologic Physics , 1995 .

[12]  R. Matthews,et al.  CT Teaching Manual: A Systematic Approach to CT Reading , 2007 .

[13]  Rafidah Zainon,et al.  Spectral Hounsfield units: a new radiological concept , 2012, European Radiology.

[14]  Thomas Flohr,et al.  Low-dose CT of the lung: potential value of iterative reconstructions , 2012, European Radiology.

[15]  S. Schindera,et al.  How reliable are Hounsfield-unit measurements in forensic radiology? , 2012, Forensic science international.

[16]  Stephan A Bolliger,et al.  Is Differentiation of Frequently Encountered Foreign Bodies in Corpses Possible by Hounsfield Density Measurement? , 2009, Journal of forensic sciences.

[17]  M. F. Reiser,et al.  Dual energy CT in clinical practice , 2011 .

[18]  R. Nelson,et al.  Decreased detection of hypovascular liver tumors with MDCT in obese patients: a phantom study. , 2011, AJR. American journal of roentgenology.

[19]  H. Alkadhi,et al.  Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations , 2013, Forensic Science, Medicine, and Pathology.

[20]  C. Boesch,et al.  Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)--a feasibility study. , 2003, Journal of forensic sciences.

[21]  Ralph Weissleder,et al.  Primer of Diagnostic Imaging , 1994 .