Evaluation of functional methods of joint centre determination for quasi-planar movement

Functional methods identify joint centres as the centre of rotation (CoR) of two adjacent movements during an ad-hoc movement. The methods have been used for functionally determining hip joint centre in gait analysis and have revealed advantages compared to predictive regression techniques. However, the current implementation of functional methods hinders its application in clinical use when subjects have difficulties performing multi-plane movements over the required range. In this study, we systematically investigated whether functional methods can be used to localise the CoR during a quasi-planar movement. The effects of the following factors were analysed: the algorithms, the range and speed of the movement, marker cluster location, marker cluster size and distance to the joint centre. A mechanical linkage was used in our study to isolate the factors of interest and give insight to variation in implementation of functional methods. Our results showed the algorithms and cluster locations significantly affected the estimate results. For all algorithms, a significantly positive relationship between CoR errors and the distance of proximal cluster coordinate location to the joint centre along the medial-lateral direction was observed while the distal marker clusters were best located as close as possible to the joint centre. By optimising the analytical and experimental factors, the transformation algorithms achieved a root mean square error (RMSE) of 5.3 mm while the sphere fitting methods yielded the best estimation with an RMSE of 2.6 mm. The transformation algorithms performed better in presence of random noise and simulated soft tissue artefacts.

[1]  Aurelio Cappozzo,et al.  Gait analysis methodology , 1984 .

[2]  U.D. Croce,et al.  Surface-marker cluster design criteria for 3-D bone movement reconstruction , 1997, IEEE Transactions on Biomedical Engineering.

[3]  A Cappello,et al.  Effects of hip joint centre mislocation on gait analysis results. , 2000, Journal of biomechanics.

[4]  P R Cavanagh,et al.  Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. , 2001, Journal of biomechanics.

[5]  Sahan Gamage,et al.  New least squares solutions for estimating the average centre of rotation and the axis of rotation. , 2002, Journal of biomechanics.

[6]  Kjartan Halvorsen,et al.  Bias compensated least squares estimate of the center of rotation. , 2003, Journal of biomechanics.

[7]  Ahmet Erdemir,et al.  Assessment of the functional method of hip joint center location subject to reduced range of hip motion. , 2004, Journal of biomechanics.

[8]  Scott L Delp,et al.  Evaluation of a new algorithm to determine the hip joint center. , 2006, Journal of biomechanics.

[9]  Aurelio Cappozzo,et al.  An optimized protocol for hip joint centre determination using the functional method. , 2006, Journal of biomechanics.

[10]  P D Milburn,et al.  Determining rigid body transformation parameters from ill-conditioned spatial marker co-ordinates. , 2006, Journal of biomechanics.

[11]  W. Taylor,et al.  A survey of formal methods for determining the centre of rotation of ball joints. , 2006, Journal of biomechanics.

[12]  P Lacouture,et al.  Effects of movement for estimating the hip joint centre. , 2007, Gait & posture.

[13]  William R Taylor,et al.  A survey of formal methods for determining functional joint axes. , 2007, Journal of biomechanics.

[14]  Aurelio Cappozzo,et al.  Hip joint centre location: an ex vivo study. , 2009, Journal of biomechanics.

[15]  Stefano Zaffagnini,et al.  Evaluation of formal methods in hip joint center assessment: an in vitro analysis. , 2010, Clinical biomechanics.

[16]  B. Galna,et al.  Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. , 2010, Gait & posture.

[17]  Morgan Sangeux,et al.  Hip joint centre localization: Evaluation on normal subjects in the context of gait analysis. , 2011, Gait & posture.

[18]  M O Heller,et al.  Effective marker placement for functional identification of the centre of rotation at the hip. , 2012, Gait & posture.

[19]  Ewa Piętka,et al.  Information Technologies in Biomedicine , 2008, Lecture Notes in Computer Science.

[20]  Michael Damsgaard,et al.  A linear soft tissue artefact model for human movement analysis: proof of concept using in vivo data. , 2012, Gait & posture.

[21]  Morgan Sangeux,et al.  A comparison of hip joint centre localisation techniques with 3-DUS for clinical gait analysis in children with cerebral palsy. , 2012, Gait & posture.

[22]  Aurelio Cappozzo,et al.  A soft tissue artefact model driven by proximal and distal joint kinematics. , 2014, Journal of biomechanics.

[23]  M. Zuk,et al.  Hip Joint Centre Localization: Evaluation of Formal Methods and Effects on Joint Kinematics , 2014 .

[24]  W. Skalli,et al.  Which method of hip joint centre localisation should be used in gait analysis? , 2014, Gait & posture.

[25]  Andrew E. Anderson,et al.  Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard , 2015, Annals of Biomedical Engineering.

[26]  R Dumas,et al.  A model of the soft tissue artefact rigid component. , 2015, Journal of biomechanics.

[27]  Hélène Pillet,et al.  Validation of hip joint center localization methods during gait analysis using 3D EOS imaging in typically developing and cerebral palsy children. , 2015, Gait & posture.

[28]  Marcus G Pandy,et al.  Standardization proposal of soft tissue artefact description for data sharing in human motion measurements. , 2017, Journal of biomechanics.