Numerical investigation of the performance and soil temperature recovery of an EATHE system under intermittent operations

One of the problems in operating earth air tunnel heat exchangers (EATHE) for cooling in summer, with soil having high specific heat and low moisture content is accumulation of heat around the pipe. The low rate of heat dissipation due to conduction restricts the performance of EATHE over subsequent years. In the present paper, numerical simulations have been performed to investigate the thermal performance and soil temperature during summer operation in Jaipur to estimate extent of soil degradation. The simulation result indicates that by the end of summer, the soil leads to thermal saturation which in turn, may render it unusable for next summer. This scenario demands for heat removal through force convection. Three strategies namely, night purging during summer operation, day operation during winter and night operation during winter were attempted to estimate extent of soil recovery. Simulation results show that the average COPs for summer, summer with night purging, winter day and winter night operation mode are 4.23, 3.68, 5.01, and 6.65 respectively. It was found that advantage of night purging is less than energy required to run blower for night purging. However, winter day/night operation offers space heating and better soil for next summer.

[1]  V. M. Puri,et al.  Heat and mass transfer analysis and modeling in unsaturated ground soils for buried tube systems , 1987 .

[2]  Wei Liu,et al.  Study of heat and moisture transfer in soil with a dry surface layer , 2005 .

[3]  S. Thepa,et al.  Cooling performance and condensation evaluation of horizontal earth tube system for the tropical greenhouse , 2013 .

[4]  Mehdi Maerefat,et al.  Passive cooling of buildings by using integrated earth to air heat exchanger and solar chimney , 2010 .

[5]  Jyotirmay Mathur,et al.  CFD analysis of EATHE system under transient conditions for intermittent operation , 2015 .

[6]  Jyotirmay Mathur,et al.  Performance analysis of earth–pipe–air heat exchanger for summer cooling , 2010 .

[7]  Onder Ozgener,et al.  Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating b , 2011 .

[8]  Ni Long,et al.  Thermal accumulation effect of ground-coupled heat pump system , 2011, 2011 International Conference on Electric Technology and Civil Engineering (ICETCE).

[9]  Ursula Eicker,et al.  Potential of geothermal heat exchangers for office building climatisation , 2009 .

[10]  J. Xamán,et al.  Numerical study of earth-to-air heat exchanger for three different climates , 2014 .

[11]  Fuxin Niu,et al.  Investigation of a coupled geothermal cooling system with earth tube and solar chimney , 2014 .

[12]  Arnold Janssens,et al.  Passive cooling in a low-energy office building , 2005 .

[13]  Onder Ozgener,et al.  A practical approach to predict soil temperature variations for geothermal (ground) heat exchangers applications , 2013 .

[14]  Jyotirmay Mathur,et al.  Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger , 2013 .

[15]  Guohui Gan,et al.  Dynamic interactions between the ground heat exchanger and environments in earth–air tunnel ventilation of buildings , 2014 .

[16]  Joaquim Vaz,et al.  Experimental and numerical analysis of an earth–air heat exchanger , 2011 .

[17]  Georgios Kokogiannakis,et al.  Theoretical and practical evaluation of an earth-tube (E-tube) ventilation system , 2011 .

[18]  Fuxin Niu,et al.  Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney , 2014 .

[19]  Joaquim Vaz,et al.  An experimental study on the use of Earth-Air Heat Exchangers (EAHE) , 2014 .

[20]  Bo Nordell,et al.  Using Fouggara for Heating and Cooling Buildings in Sahara , 2011 .

[21]  Jyotirmay Mathur,et al.  Performance analysis of earth–pipe–air heat exchanger for winter heating , 2009 .

[22]  Esmail M. A. Mokheimer,et al.  Feasibility of using ground-coupled condensers in A/C systems , 2010 .

[23]  Jyotirmay Mathur,et al.  Thermal performance investigation of hybrid earth air tunnel heat exchanger , 2012 .

[24]  Galip Temir,et al.  Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification , 2009 .

[25]  Jyotirmay Mathur,et al.  Investigation of soil thermal saturation and recovery under intermittent and continuous operation of EATHE , 2015 .

[26]  G. Tiwari,et al.  Thermal modeling of a greenhouse with an integrated earth to air heat exchanger: an experimental validation , 2004 .

[27]  Jyotirmay Mathur,et al.  Performance evaluation and economic analysis of integrated earth–air–tunnel heat exchanger–evaporative cooling system , 2012 .

[28]  Jyotirmay Mathur,et al.  Transient effect of soil thermal diffusivity on performance of EATHE system , 2015 .