Current progress in genetically encoded voltage indicators for neural activity recording.

Genetically Encoded Voltage Indicators (GEVIs) are powerful tools used to investigate neural activity in the brain. The spatiotemporal resolution of GEVIs is on a subcellular and millisecond scale, and is superior to that of the functional magnetic resonance imaging (fMRI) and electroencephalogram (EEG). Further, while patch-clamp techniques record membrane voltage for tens of neurons simultaneously, GEVIs can do so for hundreds of neurons. It is important for neuroscientists to understand the pros and cons of GEVIs and to choose appropriate ones for their specific requirements. Here, we summarize the characteristics of currently available GEVIs based on voltage sensing mechanism and provide a guideline for selecting optimal GEVIs for specific applications.

[1]  Walther Akemann,et al.  Imaging neural circuit dynamics with a voltage-sensitive fluorescent protein. , 2012, Journal of neurophysiology.

[2]  S. Luther,et al.  Sensing Cardiac Electrical Activity With a Cardiac Myocyte--Targeted Optogenetic Voltage Indicator. , 2015, Circulation research.

[3]  Lei Jin,et al.  Monitoring Brain Activity with Protein Voltage and Calcium Sensors , 2015, Scientific Reports.

[4]  D. J. Harrison,et al.  Bright and fast multi-colored voltage reporters via electrochromic FRET , 2014, Nature Communications.

[5]  Walther Akemann,et al.  Engineering and Characterization of an Enhanced Fluorescent Protein Voltage Sensor , 2007, PLoS ONE.

[6]  Walther Akemann,et al.  Imaging brain electric signals with genetically targeted voltage-sensitive fluorescent proteins , 2010, Nature Methods.

[7]  Henry Markram,et al.  Substrate Arrays of Iridium Oxide Microelectrodes for in Vitro Neuronal Interfacing , 2008, Front. Neuroeng..

[8]  T. Terwilliger,et al.  Protein tagging and detection with engineered self-assembling fragments of green fluorescent protein , 2005, Nature Biotechnology.

[9]  Ehud Y Isacoff,et al.  A Genetically Encoded Optical Probe of Membrane Voltage , 1997, Neuron.

[10]  Yasushi Okamura,et al.  Phosphoinositide phosphatase activity coupled to an intrinsic voltage sensor , 2005, Nature.

[11]  Samouil L. Farhi,et al.  All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins , 2014, Nature Methods.

[12]  Michael Z. Lin,et al.  High-fidelity optical reporting of neuronal electrical activity with an ultrafast fluorescent voltage sensor , 2014, Nature Neuroscience.

[13]  Yongxin Zhao,et al.  An Expanded Palette of Genetically Encoded Ca2+ Indicators , 2011, Science.

[14]  Benjamin F. Grewe,et al.  High-speed recording of neural spikes in awake mice and flies with a fluorescent voltage sensor , 2015, Science.

[15]  William W. Ward,et al.  SPECTRAL PERTURBATIONS OF THE AEQUOREA GREEN‐FLUORESCENT PROTEIN , 1982 .

[16]  Vincent A. Pieribone,et al.  Single Action Potentials and Subthreshold Electrical Events Imaged in Neurons with a Fluorescent Protein Voltage Probe , 2012, Neuron.

[17]  Josef Lazar,et al.  Mechanistic Studies of the Genetically Encoded Fluorescent Protein Voltage Probe ArcLight , 2014, PloS one.

[18]  Dougal Maclaurin,et al.  Mechanism of voltage-sensitive fluorescence in a microbial rhodopsin , 2013, Proceedings of the National Academy of Sciences.

[19]  Takeharu Nagai,et al.  Luminescent proteins for high-speed single-cell and whole-body imaging , 2012, Nature Communications.

[20]  D. Maclaurin,et al.  Optical recording of action potentials in mammalian neurons using a microbial rhodopsin , 2011, Nature Methods.

[21]  Thomas Knöpfel,et al.  Exploration of Fluorescent Protein Voltage Probes Based on Circularly Permuted Fluorescent Proteins , 2009, Front. Neuroeng..

[22]  V. Pieribone,et al.  A Fluorescent, Genetically-Encoded Voltage Probe Capable of Resolving Action Potentials , 2012, PloS one.

[23]  Yasushi Okamura,et al.  Improved detection of electrical activity with a voltage probe based on a voltage‐sensing phosphatase , 2013, The Journal of physiology.

[24]  Yasushi Okamura,et al.  Improving membrane voltage measurements using FRET with new fluorescent proteins , 2008, Nature Methods.

[25]  Sreekanth H. Chalasani,et al.  Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators , 2009, Nature Methods.

[26]  Nathan C. Klapoetke,et al.  A High-Light Sensitivity Optical Neural Silencer: Development and Application to Optogenetic Control of Non-Human Primate Cortex , 2010, Front. Syst. Neurosci..

[27]  H. Mutoh,et al.  Exploration of genetically encoded voltage indicators based on a chimeric voltage sensing domain , 2014, Front. Mol. Neurosci..

[28]  Adam E Cohen,et al.  Two-Photon Lifetime Imaging of Voltage Indicating Proteins as a Probe of Absolute Membrane Voltage. , 2015, Biophysical journal.

[29]  Michael W. Davidson,et al.  A bright monomeric green fluorescent protein derived from Branchiostoma lanceolatum , 2013, Nature Methods.

[30]  V. Pieribone,et al.  Genetically Targeted Optical Electrophysiology in Intact Neural Circuits , 2013, Cell.

[31]  T. Knöpfel,et al.  Design and characterization of a DNA‐encoded, voltage‐sensitive fluorescent protein , 2001, The European journal of neuroscience.