Impact of Inverter-Based Resources on Negative Sequence Quantities-Based Protection Elements

[1]  Evangelos Farantatos,et al.  Impact of Wind Generation on Power Swing Protection , 2019, IEEE Transactions on Power Delivery.

[2]  Aboutaleb HADDADI,et al.  Field validation of generic wind park models using fault records , 2019 .

[3]  Jean Mahseredjian,et al.  Safe Operation of DFIG-Based Wind Parks in Series-Compensated Systems , 2018, IEEE Transactions on Power Delivery.

[4]  John H. Smith,et al.  Fault current contributions from wind plants , 2015, 2015 68th Annual Conference for Protective Relay Engineers.

[5]  Russell Patterson,et al.  Directional comparison blocking system fundamentals , 2014, 2014 67th Annual Conference for Protective Relay Engineers.

[6]  Jean Mahseredjian,et al.  Short-Circuit Model for Type-IV Wind Turbine Generators With Decoupled Sequence Control , 2019, IEEE Transactions on Power Delivery.

[7]  Ehab F. El-Saadany,et al.  Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants—Part II: Solution Description and Evaluation , 2015, IEEE Transactions on Power Delivery.

[8]  M. Fischer,et al.  Representation of variable speed full conversion Wind Energy Converters for steady state short-circuit calculations , 2011, 2011 IEEE Power and Energy Society General Meeting.

[9]  Jean Mahseredjian,et al.  A Generic EMT-Type Model for Wind Parks With Permanent Magnet Synchronous Generator Full Size Converter Wind Turbines , 2019, IEEE Power and Energy Technology Systems Journal.

[10]  Sachin Srivastava,et al.  Behavior of self polarized Mho characteristic on lines fed from DFIG based wind farms , 2013, 2013 IEEE Innovative Smart Grid Technologies-Asia (ISGT Asia).

[11]  Charles Henville,et al.  Impact of Power-Electronic Sources on Transmission Line Ground Fault Protection , 2018, IEEE Transactions on Power Delivery.

[12]  Siemens Aktiengesellschaft,et al.  Numerical Distance Protection: Principles and Applications , 1999 .

[13]  C. Christopoulos,et al.  Phase selection based on superimposed components , 1996 .

[14]  Babu Narayanan,et al.  Power system stability and control , 2007 .

[15]  J. Lewis Blackburn,et al.  Symmetrical Components for Power Systems Engineering , 1993 .

[16]  Ehab F. El-Saadany,et al.  Distance Protection of Lines Connected to Induction Generator-Based Wind Farms During Balanced Faults , 2014, IEEE Transactions on Sustainable Energy.

[17]  Peter Schegner,et al.  Wind turbine negative sequence current control and its effect on power system protection , 2013, 2013 IEEE Power & Energy Society General Meeting.

[18]  Jean Mahseredjian,et al.  Phasor domain modeling of Type III wind turbine generator for protection studies , 2015, 2015 IEEE Power & Energy Society General Meeting.

[19]  Jean Mahseredjian,et al.  Phasor domain modeling of type-IV wind turbine generator for protection studies , 2015, 2015 IEEE Power & Energy Society General Meeting.

[20]  F. Calero Rebirth of negative-sequence quantities in protective relaying with microprocessor-based relays , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[21]  J. Horak Directional overcurrent relaying (67) concepts , 2006, 59th Annual Conference for Protective Relay Engineers, 2006..

[22]  Jean Mahseredjian,et al.  An accurate type III wind turbine generator short circuit model for protection applications , 2017, 2017 IEEE Power & Energy Society General Meeting.

[23]  Jean Mahseredjian,et al.  Short-circuit current contribution of converter interfaced wind turbines and the impact on system protection , 2013, 2013 IREP Symposium Bulk Power System Dynamics and Control - IX Optimization, Security and Control of the Emerging Power Grid.

[24]  Ehab F. El-Saadany,et al.  Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants—Part I: Problem Statement , 2015, IEEE Transactions on Power Delivery.

[25]  Rick Taylor,et al.  Transmission line applications of Directional Ground Overcurrent Relays Texas A&M conference , 2011, 2011 64th Annual Conference for Protective Relay Engineers.

[26]  Gustavo Brunello,et al.  What ’ s New in C 37 . 113 TM-2015 , IEEE Guide for Protective Relay Applications to Transmission Lines , 2017 .

[27]  Chen-Ching Liu,et al.  Distance Protection of AC Grid With HVDC-Connected Offshore Wind Generators , 2014, IEEE Transactions on Power Delivery.

[28]  Pedro Rodriguez,et al.  Short circuit signatures from different wind turbine generator types , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[29]  Yilu Liu,et al.  Fault Characteristics of Distributed Solar Generation , 2020, IEEE Transactions on Power Delivery.

[30]  David Costello,et al.  Determining the faulted phase , 2010, 2010 63rd Annual Conference for Protective Relay Engineers.

[31]  Dustin F. Howard,et al.  Short-circuit currents in wind-turbine generator networks , 2013 .

[32]  A. Takeuchi,et al.  A digital distance relay using negative sequence current , 1990 .

[33]  Ronald G. Harley,et al.  Short-Circuit Modeling of DFIGs With Uninterrupted Control , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.