Operation of Wind-Turbine-Driven DFIG Systems Under Distorted Grid Voltage Conditions: Analysis and Experimental Validations

This paper presents enhanced control strategies for doubly fed induction generator (DFIG)-based wind power generation systems under distorted grid voltage conditions. The mathematical model of DFIG, in view of the fifth- and seventh-order components of grid voltage harmonics, is proposed and analyzed in detail. Based on the analytical model, further studies are conducted on the distortions of stator/rotor currents and the oscillations in the stator active/reactive powers as well as the electromagnetic torque, where the impact of DFIG's load conditions is considered. Meanwhile, alternative rotor current references are calculated to enhance the uninterruptable operation capability of the wind-turbine-driven DFIG systems under distorted grid conditions. An improved software PLL is designed, which is capable of accurately and rapidly tracking the frequency and phase angle of the fundamental grid voltage under distorted grid conditions. A proportional integral plus resonant (PI-R) current controller in the synchronously rotating (dq) reference frame is employed to simultaneously regulate the fundamental and harmonic components of rotor currents without any sequential component decomposition. Experiment results on a 3-kW DFIG prototype demonstrate the correctness of the analytical results and the effectiveness of the software PLL and PI-R current controller when the grid voltage is distorted.

[1]  Raul Rabinovici,et al.  Distribution Generation Case Study: Electric Wind Farm with Doubly Fed Induction Generators , 2006, 2006 IEEE 24th Convention of Electrical & Electronics Engineers in Israel.

[2]  Boon-Teck Ooi,et al.  Magnitude and frequency control of grid-connected doubly fed induction generator based on synchronised model for wind power generation , 2010 .

[3]  E. Monmasson,et al.  Design of an output LC filter for a doubly fed induction generator supplying non-linear loads for aircraft applications , 2004, 2004 IEEE International Symposium on Industrial Electronics.

[4]  Hemanshu R Pota,et al.  Simultaneous STATCOM and Pitch Angle Control for Improved LVRT Capability of Fixed-Speed Wind Turbines , 2010, IEEE Transactions on Sustainable Energy.

[5]  Mohsen Rahimi,et al.  Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement , 2010 .

[6]  Barry W. Williams,et al.  Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators , 2009, IEEE Transactions on Industrial Electronics.

[7]  Jie Wu,et al.  Integral Sliding-Mode Direct Torque Control of Doubly-Fed Induction Generators Under Unbalanced Grid Voltage , 2010, IEEE Transactions on Energy Conversion.

[8]  Poh Chiang Loh,et al.  High-performance harmonic extraction algorithm for a 25 kV traction power quality conditioner , 2004 .

[9]  Wei-Jen Lee,et al.  Effects of Voltage Unbalance and System Harmonics on the Performance of Doubly Fed Induction Wind Generators , 2010 .

[10]  Hong-Hee Lee,et al.  Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems , 2011 .

[11]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[12]  S.M. Muyeen,et al.  A Variable Speed Wind Turbine Control Strategy to Meet Wind Farm Grid Code Requirements , 2010, IEEE Transactions on Power Systems.

[13]  G. Abad,et al.  Direct Power Control of Doubly-Fed-Induction-Generator-Based Wind Turbines Under Unbalanced Grid Voltage , 2010, IEEE Transactions on Power Electronics.

[14]  Jon Are Suul,et al.  STATCOM-Based Indirect Torque Control of Induction Machines During Voltage Recovery After Grid Faults , 2010, IEEE Transactions on Power Electronics.

[15]  Jiabing Hu,et al.  DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions – Analysis and control design , 2011 .

[16]  A. Gaillard,et al.  Active filtering capability of WECS with DFIG for grid power quality improvement , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[17]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[18]  Zhe Zhang,et al.  The impacts of distributed doubly-fed induction generators on smart distribution Grid protection , 2010, Proceedings of the 2010 International Conference on Modelling, Identification and Control.

[19]  Yikang He,et al.  Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip , 2006 .

[20]  Gi-Gab Yoon,et al.  Active Use of DFIG-Based Variable-Speed Wind-Turbine for Voltage Regulation at a Remote Location , 2007, IEEE Transactions on Power Systems.

[21]  Jon Are Suul,et al.  Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC , 2008, IEEE Transactions on Power Electronics.

[22]  A.P. Martins,et al.  Rotor Current Controller with Voltage Harmonics Compensation for a DFIG Operating under Unbalanced and Distorted Stator Voltage , 2007, IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society.

[23]  A. Nasiri,et al.  A Dynamic LVRT Solution for Doubly Fed Induction Generators , 2010, IEEE Transactions on Power Electronics.

[24]  S. Djurovic,et al.  Influence of supply harmonic voltages on DFIG stator current and power spectrum , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[25]  Heng Nian,et al.  Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions , 2011, IEEE Transactions on Energy Conversion.

[26]  A. Bentounsi,et al.  Simulation of a DFIG-based wind turbine with active filtering function using Matlab/Simulink , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.