Improved power hardware in the loop interface methods via impedance matching

The power hardware in the loop (PHIL) method is a reliable simulation and validation technology. It can be utilized to augment the test of electrical, mechanical or electromechanical components or subsystems with high power ratings. In addition, it can also be used to characterize their behavior when connected to some complex electrical networks or mechanical environment. Reliable and safe performances are paramount in a PHIL system. Thus, the proper PHIL modeling and power interface validation precedes any experimental implementation. In this paper, we focus on the stability and accuracy of the damping impedance method (DIM) and we propose the modified DIM method which increases the accuracy and the stability of the PHIL through dynamic impedance matching of the load and the linking impedance component. Different cases are introduced in order to study the parameters which have effects on the PHIL system. First, the basic DIM method and the modified DIM architecture are introduced, and then two cases consisting of a constant load and a variable load will be presented, respectively.

[1]  Thomas Baldwin,et al.  Simulation by Selecting Appropriate Interface Algorithms , 2007 .

[2]  Christian Dufour,et al.  A Method to Stabilize a Power Hardware-inthe-loop Simulation of Inductor Coupled Systems , 2009 .

[3]  Michael Steurer,et al.  A Megawatt-Scale Power Hardware-in-the-Loop Simulation Setup for Motor Drives , 2010, IEEE Transactions on Industrial Electronics.

[4]  Seddik Bacha,et al.  Real-time hybrid facility for the study of distributed power generation systems , 2008 .

[5]  C. S. Edrington,et al.  Investigation of HIL interfaces in nonlinear load studies , 2012, 2012 North American Power Symposium (NAPS).

[6]  Alexander Viehweider,et al.  Power hardware in the loop simulation with feedback current filtering for electric systems , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[7]  Shu Yuen Ron Hui,et al.  Decoupled simulation of DC-linked power electronic systems using transmission-line links , 1994 .

[8]  P. Holmberg,et al.  Expanding an Analogue HVDC Simulator's Modelling Capability Using a Real-Time Digital Simulator (RTDS) , 1995, ICDS '95. First International Conference on Digital Power System Simulators.

[9]  C. S. Edrington,et al.  Application of power hardware-in-the-loop for electric vehicles: A case study utilizing switched reluctance machines , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[10]  Vladimir B. Dmitriev-Zdorov Generalized coupling as a way to improve the convergence in relaxation-based solvers , 1996, Proceedings EURO-DAC '96. European Design Automation Conference with EURO-VHDL '96 and Exhibition.