Distributed FACTS stabilization scheme for efficient utilization of distributed wind energy systems

Summary Because of the growing usage of wind energy systems worldwide, more challenges in power quality and microgrid stabilization domains have emerged. In this paper, a new distributed FACTS-based green plug-switched filter capacitor (GP-SFC) filter is presented for efficient utilization of microgrid-connected wind energy systems. The primary goals are improving the energy use, stabilizing voltage dynamically, enhancing power quality, and improving the power factor at the common interface AC buses of the microgrid-connected wind system. The proposed GP-SFC topology is modelled and simulated using MATLAB/Simulink software. A dynamic multiloop error-driven controller is proposed for adjusting the pulse switching pattern of the variable speed wind turbine system. In addition to the low cost of the proposed GP-SFC filter, the results show that it can promote the use of wind energy system under load changes and temporary fault conditions. Besides, the proposed GP-SFC guarantees high-speed controllability while maintaining its capability for power factor correction and voltage support using its switched shunt capacitor. Also, the system performance with the proposed filter is compared with the system with a conventional D-STATCOM compensator. The results validate the effectiveness and robustness of the GP-SFC topology.

[1]  N. Loganathan,et al.  Power quality improvement of a grid-connected wind energy conversion system with harmonics reduction using FACTS device , 2012, IEEE-International Conference On Advances In Engineering, Science And Management (ICAESM -2012).

[2]  Fatiha Lakdja,et al.  Synthesis integrating wind generation and FACTS of network , 2014, 2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM).

[3]  Shady H. E. Abdel Aleem,et al.  Optimal passive filter design for effective utilization of cables and transformers under non-sinusoidal conditions , 2014, 2014 16th International Conference on Harmonics and Quality of Power (ICHQP).

[4]  Adel M. Sharaf,et al.  Novel Low Cost Green Plug Smart Filter Soft Starter (GP-SF-SS) Schemes for Small Horse Power Motorized Loads , 2010 .

[5]  Mkadmi Chedia,et al.  Experimental Study of the Infiltration in the Gafsa Oases in Tunisia , 2012 .

[6]  Ahmed Faheem Zobaa,et al.  A New Approach for Harmonic Distortion Minimization in Power Systems Supplying Nonlinear Loads , 2014, IEEE Transactions on Industrial Informatics.

[7]  Yijia Cao,et al.  Capacity optimisation method of distribution static synchronous compensator considering the risk of voltage sag in high-voltage distribution networks , 2015 .

[8]  G. T. Heydt,et al.  Power Quality Engineering , 2001, IEEE Power Engineering Review.

[9]  Abdelazeem A. Abdelsalam,et al.  Corrigendum to “Performance enhancement of hybrid AC/DC microgrid based D-FACTS” [Int. J. Electr. Power Energy Syst. 63 (2014) 382–393] , 2015 .

[10]  Mojtaba Khederzadeh,et al.  STATCOM modeling impacts on performance evaluation of distance protection of transmission lines , 2011 .

[11]  Ismail H. Altas,et al.  A novel hybrid active filter compensator for stabilization of wind-utility grid interface scheme , 2010 .

[12]  Abdelazeem A. Abdelsalam,et al.  Microgrid energy management in grid-connected and islanding modes based on SVC , 2014 .

[13]  Hala M. Abdel Mageed,et al.  Assessment of energy credits for the enhancement of the Egyptian Green Pyramid Rating System , 2015 .

[14]  Roy Billinton,et al.  Probabilistic technique for sizing FACTS devices for steady-state voltage profile enhancement , 2009 .

[15]  Abdelazeem A. Abdelsalam,et al.  A novel facts compensation scheme for power quality improvement in wind Smart Grid , 2012, 2012 25th IEEE Canadian Conference on Electrical and Computer Engineering (CCECE).

[16]  Ahmed F. Zobaa,et al.  Power Quality in Future Electrical Power Systems , 2017 .

[17]  J. R. McDonald,et al.  Reasoning with modal logic for power plant condition monitoring , 2001 .

[18]  Balarko Chaudhuri,et al.  Implementation and test results of a wide-area measurement-based controller for damping interarea oscillations considering signal-transmission delay , 2007 .

[19]  Hemanshu R. Pota,et al.  Improved low-voltage-ride-through capability of fixed-speed wind turbines using decentralised control of STATCOM with energy storage system , 2012 .

[20]  Sajjad Golshannavaz,et al.  Distributed static series compensator (DSSC) for subsynchronous resonance alleviation and power oscillation damping , 2012 .

[21]  Bijay Ketan Panigrahi,et al.  Adaptive distance protection scheme for shunt-FACTS compensated line connecting wind farm , 2016 .