Utility of the LevelCheck Algorithm for Decision Support in Vertebral Localization

Study Design. An automatic radiographic labeling algorithm called “LevelCheck” was analyzed as a means of decision support for target localization in spine surgery. The potential clinical utility and scenarios in which LevelCheck is likely to be the most beneficial were assessed in a retrospective clinical data set (398 cases) in terms of expert consensus from a multi-reader study (three spine surgeons). Objective. The aim of this study was to evaluate the potential utility of the LevelCheck algorithm for vertebrae localization. Summary of Background Data. Three hundred ninety-eight intraoperative radiographs and 178 preoperative computed tomographic (CT) images for patients undergoing spine surgery in cervical, thoracic, lumbar regions. Methods. Vertebral labels annotated in preoperative CT image were overlaid on intraoperative radiographs via 3D-2D registration. Three spine surgeons assessed the radiographs and LevelCheck labeling according to a questionnaire evaluating performance, utility, and suitability to surgical workflow. Geometric accuracy and registration run time were measured for each case. Results. LevelCheck was judged to be helpful in 42.2% of the cases (168/398), to improve confidence in 30.6% of the cases (122/398), and in no case diminished performance (0/398), supporting its potential as an independent check and assistant to decision support in spine surgery. The clinical contexts for which the method was judged most likely to be beneficial included the following scenarios: images with a lack of conspicuous anatomical landmarks; level counting across long spine segments; vertebrae obscured by other anatomy (e.g., shoulders); poor radiographic image quality; and anatomical variations/abnormalities. The method demonstrated 100% geometric accuracy (i.e., overlaid labels within the correct vertebral level in all cases) and did not introduce ambiguity in image interpretation. Conclusion. LevelCheck is a potentially useful means of decision support in vertebral level localization in spine surgery. Level of Evidence: N/A

[1]  M. Makary,et al.  Surgical never events in the United States. , 2013, Surgery.

[2]  S. Schafer,et al.  Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance. , 2011, Medical physics.

[3]  Gerhard Kleinszig,et al.  Automatic masking for robust 3D-2D image registration in image-guided spine surgery , 2016, SPIE Medical Imaging.

[4]  A Uneri,et al.  3D–2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch , 2016, Physics in medicine and biology.

[5]  S. Schafer,et al.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery , 2012, Physics in medicine and biology.

[6]  G. Konin,et al.  Lumbosacral Transitional Vertebrae: Classification, Imaging Findings, and Clinical Relevance , 2010, American Journal of Neuroradiology.

[7]  S. Schafer,et al.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance. , 2011, Medical physics.

[8]  Guoyan Zheng,et al.  i) Registration techniques for computer navigation , 2007 .

[9]  S. Mutlu,et al.  Retrospective Cohort Study of the Prevalence of Lumbosacral Transitional Vertebra in a Wide and Well-Represented Population , 2013, Arthritis.

[10]  Marie Diener-West,et al.  Surgical Never Events in the United States , 2013 .

[11]  Tharindu De Silva,et al.  Automatic Localization of Target Vertebrae in Spine Surgery: Clinical Evaluation of the LevelCheck Registration Algorithm , 2015, Spine.

[12]  Daniel Mirota,et al.  TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery , 2011, International Journal of Computer Assisted Radiology and Surgery.

[13]  J H Siewerdsen,et al.  Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions. , 2009, Medical physics.

[14]  Yoshito Otake,et al.  Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation , 2013, Physics in medicine and biology.

[15]  Susan F Paparella Taking another look at independent double checks. , 2013, Journal of emergency nursing: JEN : official publication of the Emergency Department Nurses Association.

[16]  Mohammad Alfawareh,et al.  The Prevalence of Wrong Level Surgery Among Spine Surgeons , 2008, Spine.

[17]  J H Siewerdsen,et al.  Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery. , 2007, Medical physics.

[18]  K. Cleary,et al.  Image-guided interventions: technology review and clinical applications. , 2010, Annual review of biomedical engineering.

[19]  Yoshito Otake,et al.  3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation , 2015, Physics in medicine and biology.