A viscoelastic anisotropic hyperelastic constitutive model of the human cornea

A constitutive model based on the continuum mechanics theory has been developed which represents interlamellar cohesion, regional variation of collagen fibril density, 3D anisotropy and both age-related viscoelastic and hyperelastic stiffening behaviour of the human cornea. Experimental data gathered from a number of previous studies on 48 ex vivo human cornea (inflation and shear tests) enabled calibration of the constitutive model by numerical analysis. Wide-angle X-ray scattering and electron microscopy provided measured data which quantify microstructural arrangements associated with stiffness. The present study measures stiffness parallel to the lamellae of the cornea which approximately doubles with an increase in strain rate from 0.5 to 5%/min, while the underlying stromal matrix provides a stiffness 2–3 orders of magnitude lower than the lamellae. The model has been simultaneously calibrated to within 3% error across three age groups ranging from 50 to 95 years and three strain rates across the two loading scenarios. Age and strain-rate-dependent material coefficients allow numerical simulation under varying loading scenarios for an individual patient with material stiffness approximated by their age. This present study addresses a significant gap in numerical representation of the cornea and has great potential in daily clinical practice for the planning and optimisation of corrective procedures and in preclinical optimisation of diagnostic procedures.

[1]  C. Roberts,et al.  A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. , 2008, Investigative ophthalmology & visual science.

[2]  David A. Hoeltzel,et al.  Comments on 'The mechanical properties of the rabbit and human cornea'. , 1991, Journal of biomechanics.

[3]  Craig Boote,et al.  Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications. , 2003, Investigative ophthalmology & visual science.

[4]  A. Elsheikh,et al.  Ultrastructural changes in the retinopathy, globe enlarged (rge) chick cornea☆ , 2009, Journal of structural biology.

[5]  S. Azen,et al.  Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. , 2007, Ophthalmology.

[6]  Ronald B. Rabbetts,et al.  Clinical Visual Optics , 1984 .

[7]  Craig Boote,et al.  Mapping collagen organization in the human cornea: left and right eyes are structurally distinct. , 2006, Investigative ophthalmology & visual science.

[8]  Yang Yang,et al.  Corneal hyper-viscoelastic model: derivations, experiments, and simulations. , 2015, Acta of bioengineering and biomechanics.

[9]  A. Elsheikh,et al.  Assessment of Corneal Biomechanical Properties and Their Variation with Age , 2007, Current eye research.

[10]  B Calvo,et al.  Biomechanical modeling of refractive corneal surgery. , 2006, Journal of biomechanical engineering.

[11]  A. Pandolfi,et al.  A model for the human cornea: constitutive formulation and numerical analysis , 2006, Biomechanics and modeling in mechanobiology.

[12]  A. Elsheikh,et al.  Development and validation of a correction equation for Corvis tonometry , 2016, Computer methods in biomechanics and biomedical engineering.

[13]  Timothy J Freegard,et al.  The physical basis of transparency of the normal cornea , 1997, Eye.

[14]  W A Douthwaite,et al.  The EyeSys videokeratoscopic assessment of apical radius and p‐value in the normal human cornea , 1999, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[15]  Ultrastructural Changes , 2020, Muscle Biopsy.

[16]  P. Pinsky,et al.  The role of 3-D collagen organization in stromal elasticity: a model based on X-ray diffraction data and second harmonic-generated images , 2013, Biomechanics and Modeling in Mechanobiology.

[17]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[18]  X Larrea,et al.  Biomechanical model of human cornea based on stromal microstructure. , 2010, Journal of biomechanics.

[19]  Bernd Markert,et al.  A general polyconvex strain‐energy function for fiber‐reinforced materials , 2005 .

[20]  T. Ushiki,et al.  The three-dimensional organization of collagen fibrils in the human cornea and sclera. , 1991, Investigative ophthalmology & visual science.

[21]  Irving Fatt,et al.  Physiology of the eye : an introduction to the vegetative functions , 1978 .

[22]  B. Boyce,et al.  An inverse finite element method for determining the anisotropic properties of the cornea , 2011, Biomechanics and modeling in mechanobiology.

[23]  K. Xiong,et al.  Study on establishment and mechanics application of finite element model of bovine eye , 2015, BMC Ophthalmology.

[24]  George C. Woo,et al.  CLINICAL VISUAL OPTICS , 1991 .

[25]  Jun Liu,et al.  Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis , 2005, Journal of cataract and refractive surgery.

[26]  Günther Meschke,et al.  Constitutive modeling of crimped collagen fibrils in soft tissues. , 2009, Journal of the mechanical behavior of biomedical materials.

[27]  P. Pinsky,et al.  Computational modeling of mechanical anisotropy in the cornea and sclera , 2005, Journal of cataract and refractive surgery.

[28]  Michael F. Land,et al.  The Human Eye: Structure and Function , 1999, Nature Medicine.

[29]  Gerhard A. Holzapfel,et al.  Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science , 2000 .

[30]  Sadegh Imani Yengejeh,et al.  Finite Element Modeling , 2015 .

[31]  K. Meek,et al.  X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus. , 2004, Structure.

[32]  J. Trewhella X‐Ray Scattering , 2002 .

[33]  Günther Meschke,et al.  A computational remodeling approach to predict the physiological architecture of the collagen fibril network in corneo-scleral shells , 2010, Biomechanics and modeling in mechanobiology.

[34]  G. Holzapfel,et al.  Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations. , 2008, Journal of biomechanical engineering.

[35]  Gerhard A. Holzapfel,et al.  A viscoelastic model for fiber-reinforced composites at finite strains: Continuum basis, computational aspects and applications , 2001 .

[36]  B. Boyce,et al.  A nonlinear anisotropic viscoelastic model for the tensile behavior of the corneal stroma. , 2008, Journal of biomechanical engineering.

[37]  R. T. Hart,et al.  Finite element modeling of the viscoelastic responses of the eye during microvolumetric changes , 2013, Journal of biomedical science and engineering.

[38]  A. Elsheikh,et al.  Biomechanical model of the human cornea: considering shear stiffness and regional variation of collagen anisotropy and density. , 2015, Journal of The Mechanical Behavior of Biomedical Materials.

[39]  B. Boyce,et al.  Stress-controlled viscoelastic tensile response of bovine cornea. , 2007, Journal of biomechanics.

[40]  A. Elsheikh,et al.  Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes. , 2015, Experimental eye research.

[41]  J. Lai,et al.  Efficacy of selective laser trabeculoplasty for normal tension glaucoma: 1 year results , 2015, BMC Ophthalmology.

[42]  A. Elsheikh,et al.  Numerical Study of the Effect of Corneal Layered Structure on Ocular Biomechanics , 2009, Current eye research.

[43]  K. Meek,et al.  Circumcorneal annulus of collagen fibrils in the human limbus. , 1998, Investigative ophthalmology & visual science.

[44]  S. Marcos,et al.  Corneal Viscoelastic Properties from Finite-Element Analysis of In Vivo Air-Puff Deformation , 2014, PloS one.

[45]  C. Boote,et al.  The organization of collagen in the corneal stroma. , 2004, Experimental eye research.

[46]  D. Maurice,et al.  The mechanical properties of the rabbit and human cornea. , 1986, Journal of biomechanics.