Perception-driven IT-CADe analysis for the detection of masses in screening mammography: initial investigation

We have previously reported an interactive information-theoretic CADe (IT-CADe) system for the detection of masses in screening mammograms. The system operates in either traditional static mode or in interactive mode whenever the user requests a second opinion. In this study we report preliminary investigation of a new paradigm of clinical integration, guided by the user's eye-gazing and reporting patterns. An observer study was conducted in which 6 radiologists evaluated 20 mammographic cases while wearing a head-mounted eye-tracking device. For each radiologistreported location, eye-gazing data were collected. Image locations that attracted prolonged dwelling (>1000msec) but were not reported were also recorded. Fixed size regions of interest (ROIs) were extracted around all above locations and analyzed using the IT-CADe system. Preliminary analysis showed that IT-CADe correctly confirmed 100% of reported true mass locations while eliminating 12.5% of the reported false positive locations. For unreported locations that attracted long dwelling, IT-CADe identified 4/6 false negative errors (i.e., errors of decision) while overcalling 8/84 TN decisions. Finally, for missed true masses that attracted short (i.e., errors of recognition) or no dwelling at all (i.e., errors of search), IT-CADe detected 5/8 of them. These results suggest that IT-CADe customization to the user's eye-gazing and reporting pattern could potentially help delineate the various sources of diagnostic error (search, recognition, decision) for each individual user and provide targeted decision support, thus improving the human-CAD synergy.

[1]  Dianne Georgian-Smith,et al.  Blinded comparison of computer-aided detection with human second reading in screening mammography. , 2007, AJR. American journal of roentgenology.

[2]  D. Gur,et al.  Head-mounted versus remote eye tracking of radiologists searching for breast cancer: a comparison. , 2006, Academic radiology.

[3]  Elizabeth A Krupinski,et al.  Computer-aided detection in clinical environment: benefits and challenges for radiologists. , 2004, Radiology.

[4]  Claudia Mello-Thoms,et al.  How does the perception of a lesion influence visual search strategy in mammogram reading? , 2006, Academic radiology.

[5]  Jacek M Zurada,et al.  Selection of examples in case-based computer-aided decision systems , 2008, Physics in medicine and biology.

[6]  H L Kundel,et al.  Nature of expertise in searching mammograms for breast masses , 1996, Medical Imaging.

[7]  C. Floyd,et al.  Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms. , 2006, Medical physics.

[8]  T. Donovan,et al.  Detection or decision errors? Missed lung cancer from the posteroanterior chest radiograph. , 2004, The British journal of radiology.

[9]  C. D'Orsi,et al.  Influence of computer-aided detection on performance of screening mammography. , 2007, The New England journal of medicine.

[10]  Lorenzo Strigini,et al.  CAD in mammography: lesion-level versus case-level analysis of the effects of prompts on human decisions , 2008, International Journal of Computer Assisted Radiology and Surgery.

[11]  H L Kundel,et al.  Blinded review of retrospectively visible unreported breast cancers: an eye-position analysis. , 2001, Radiology.

[12]  Elizabeth A. Krupinski,et al.  Enhancing recognition of lesions in radiographic images using perceptual feedback , 1998 .

[13]  P. Taylor,et al.  An evaluation of the impact of computer-based prompts on screen readers' interpretation of mammograms. , 2004, The British journal of radiology.

[14]  Christina Ilvento,et al.  Improved cancer detection using computer-aided detection with diagnostic and screening mammography: prospective study of 104 cancers. , 2006, AJR. American journal of roentgenology.

[15]  C. Lehman,et al.  Testing the effect of computer-assisted detection on interpretive performance in screening mammography. , 2006, AJR. American journal of roentgenology.

[16]  E. Krupinski,et al.  Computer-displayed eye position as a visual aid to pulmonary nodule interpretation. , 1990, Investigative radiology.

[17]  H L Kundel,et al.  Visual search patterns and experience with radiological images. , 1972, Radiology.

[18]  KathleenR. Brandt,et al.  Screening mammograms: interpretation with computer-aided detection--prospective evaluation. , 2006, Radiology.

[19]  Priscilla J Slanetz,et al.  Prospective assessment of computer-aided detection in interpretation of screening mammography. , 2006, AJR. American journal of roentgenology.

[20]  Lubomir M. Hadjiiski,et al.  Bilateral analysis based false positive reduction for computer-aided mass detection. , 2007, Medical physics.

[21]  Alastair G. Gale,et al.  Defining the perceptual processes involved with mammographic diagnostic errors , 1996, Medical Imaging.

[22]  J. Reynolds,et al.  Impact of computer-aided detection in a regional screening mammography program. , 2005, AJR. American journal of roentgenology.

[23]  Luisa P. Wallace,et al.  Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system. , 2004, Journal of the National Cancer Institute.

[24]  K. Berbaum,et al.  Can a checklist reduce SOS errors in chest radiography? , 2006, Academic radiology.

[25]  N. Karssemeijer,et al.  Analysis of probed regions in an interactive CAD system for the detection of masses in mammograms , 2009, Medical Imaging.

[26]  Luisa P. Wallace,et al.  Multiview-based computer-aided detection scheme for breast masses. , 2006, Medical physics.

[27]  T. Freer,et al.  Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. , 2001, Radiology.

[28]  Elizabeth A. Krupinski,et al.  Influence of experience on scanning strategies in mammography , 1996, Medical Imaging.

[29]  E. Krupinski,et al.  Comparison of eye position versus computer identified microcalcification clusters on mammograms. , 1997, Medical physics.

[30]  Jules Sumkin,et al.  Effects of lesion conspicuity on visual search in mammogram reading. , 2005, Academic radiology.

[31]  Nico Karssemeijer,et al.  Combining two mammographic projections in a computer aided mass detection method. , 2007, Medical physics.

[32]  Berkman Sahiner,et al.  Improvement of computerized mass detection on mammograms: fusion of two-view information. , 2002, Medical physics.

[33]  H L Kundel,et al.  Mechanism of satisfaction of search: eye position recordings in the reading of chest radiographs. , 1995, Radiology.

[34]  K S Berbaum,et al.  Role of faulty visual search in the satisfaction of search effect in chest radiography. , 1998, Academic radiology.

[35]  S. Astley,et al.  Single reading with computer-aided detection for screening mammography. , 2008, The New England journal of medicine.

[36]  Kevin S Berbaum,et al.  Can order of report prevent satisfaction of search in abdominal contrast studies? , 2005, Academic radiology.

[37]  Wende Logan-Young,et al.  Evaluation of computer-aided detection systems in the detection of small invasive breast carcinoma. , 2007, Radiology.

[38]  Richard H. Moore,et al.  Current Status of the Digital Database for Screening Mammography , 1998, Digital Mammography / IWDM.

[39]  E. Krupinski,et al.  Visual scanning patterns of radiologists searching mammograms. , 1996, Academic radiology.

[40]  Bin Zheng,et al.  Computer-Aided Diagnosis in Mammography Using Content-Based Image Retrieval Approaches: Current Status and Future Perspectives , 2009, Algorithms.

[41]  M. Gromet Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms. , 2008, AJR. American journal of roentgenology.

[42]  Debra M Ikeda,et al.  Computer-aided detection with screening mammography in a university hospital setting. , 2005, Radiology.

[43]  Lorenzo Strigini,et al.  Human-machine diversity in the use of computerised advisory systems: a case study , 2003, 2003 International Conference on Dependable Systems and Networks, 2003. Proceedings..

[44]  Swatee Singh,et al.  Information-theoretic CAD system in mammography: entropy-based indexing for computational efficiency and robust performance. , 2007, Medical physics.