Implementation of open-loop control for interleaved DCM/CCM boundary boost PFC converters

This paper is focused on the implementation of the open-loop control method for interleaved DCM/CCM boundary boost PFC converters where the slave converter is synchronized to the turn-on instant of the master converter and both converters operate with current-mode control. It is shown that this method is the only open-loop control method that provides a stable operation. Implementations of the master-slave synchronization circuit in both analog and digital technology are described. Experimental results obtained on a 400-W, universal input, 400-V output prototype circuit with two interleaved DCM/CCM boundary boost PFC converters controlled by an integrated control circuit currently being developed are provided.

[1]  Jose Renes Pinheiro,et al.  A ZCT auxiliary commutation circuit for interleaved boost converters operating in critical conduction mode , 2002 .

[2]  Jih-Sheng Lai,et al.  Design consideration for power factor correction boost converter operating at the boundary of continuous conduction mode and discontinuous conduction mode , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[3]  Y.-M. Chen,et al.  Integrated Circuits of a PFC Controller for Interleaved Critical-Mode Boost Converters , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[4]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[5]  Milan M. Jovanovic,et al.  A comparative study of soft-switched CCM boost rectifiers and interleaved variable-frequency DCM boost rectifier , 2000, APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058).

[6]  M.M. Jovanovic,et al.  Open-Loop Control Methods for Interleaved DCM/CCM Boundary Boost PFC Converters , 2008, IEEE Transactions on Power Electronics.

[7]  Markus Voelter,et al.  State of the Art , 1997, Pediatric Research.

[8]  M. S. Elmore Input current ripple cancellation in synchronized, parallel connected critically continuous boost converters , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[9]  Milan M. Jovanovic,et al.  Evaluation of input current in the critical mode boost PFC converter for distributed power systems , 2001, APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181).

[10]  Milan M. Jovanovic,et al.  State-of-the-art, single-phase, active power-factor-correction techniques for high-power applications - an overview , 2005, IEEE Transactions on Industrial Electronics.

[11]  L. Huber,et al.  Line current distortions of DCM/CCM boundary boost PFC converter , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[12]  T. Ishii,et al.  Power factor correction using interleaving technique for critical mode switching converters , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[13]  K.T. Kim,et al.  Variable On-time Control of the Critical Conduction Mode Boost Power Factor Correction Converter to Improve Zero-crossing Distortion , 2005, 2005 International Conference on Power Electronics and Drives Systems.