Design and analysis of a spectro-angular surface plasmon resonance biosensor operating in the visible spectrum.

Surface plasmon resonance (SPR) sensing is one of the most widely used methods to implement biosensing due to its sensitivity and capacity for label-free detection. Whilst most commercial SPR sensors operate in the angular regime, it has recently been shown that an increase in sensitivity and a greater robustness against noise can be achieved by measuring the reflectivity when varying both the angle and wavelength simultaneously, in a so-called spectro-angular SPR biosensor. A single value decomposition method is used to project the two-dimensional spectro-angular reflection signal onto a basis set and allow the image obtained from an unknown refractive index sample to be compared very accurately with a pre-calculated reference set. Herein we demonstrate that a previously reported system operated in the near infra-red has a lower detection limit when operating in the visible spectrum due to the improved spatial resolution and numerical precision of the image sensor. The SPR biosensor presented here has an experimental detection limit of 9.8 × 10(-7) refractive index unit. To validate the system as a biosensor, we also performed the detection of synthetic RNA from pathogenic Legionella pneumophila with the developed biosensing platform.

[1]  Jiandong Hu,et al.  An Improved Centroid Algorithm for a Surface Plasmon Resonance Bioanalyzer Using Microprocessors , 2009, 2009 Symposium on Photonics and Optoelectronics.

[2]  M. Erdogan,et al.  Swelling behavior of pyrene-labelled polystyrene LB thin film exposed to various volatile organic vapors , 2014 .

[3]  M. Daimon,et al.  Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region. , 2007, Applied optics.

[4]  I. Abdulhalim,et al.  Figure-of-merit enhancement of surface plasmon resonance sensors in the spectral interrogation. , 2012, Optics letters.

[5]  M. Swanson,et al.  Legionella pneumophila pathogesesis: a fateful journey from amoebae to macrophages. , 2000, Annual review of microbiology.

[6]  Teodor Veres,et al.  Sub-femtomole detection of 16s rRNA from Legionella pneumophila using surface plasmon resonance imaging. , 2014, Biosensors & bioelectronics.

[7]  Maryam Tabrizian,et al.  Designed biointerface using near-infrared quantum dots for ultrasensitive surface plasmon resonance imaging biosensors. , 2011, Analytical chemistry.

[8]  U. Tamer,et al.  Comparison of sensing strategies in SPR biosensor for rapid and sensitive enumeration of bacteria. , 2012, Biosensors & bioelectronics.

[9]  K. Qi,et al.  Surface plasmon resonance technique for directly probing the interaction of DNA and graphene oxide and ultra-sensitive biosensing. , 2014, Biosensors & bioelectronics.

[10]  Andrew G Kirk,et al.  Numerical method for high accuracy index of refraction estimation for spectro-angular surface plasmon resonance systems. , 2008, Optics express.

[11]  Audrey Berrier,et al.  Enhancing the gas sensitivity of surface plasmon resonance with a nanoporous silica matrix , 2011 .

[12]  Sandrine Filion-Côté,et al.  Analysis of surface plasmon spectro-angular reflectance spectrum: real-time measurement, resolution limits, and applications to biosensing. , 2011, Optics letters.

[13]  J. Homola,et al.  Surface plasmon resonance (SPR) sensors: approaching their limits? , 2009, Optics express.

[14]  Vincent Aimez,et al.  Biosensing based on surface plasmon resonance and living cells. , 2009, Biosensors & bioelectronics.

[15]  J. Homola Surface plasmon resonance sensors for detection of chemical and biological species. , 2008, Chemical reviews.