Roof Isolation with Tuned Mass-based Systems and Application to a Prefabricated Building

The earthquake-resistant design of prefabricated buildings is currently the focus of attention, especially for industrial buildings that require a high level of seismic protection. The standard design approach, based on ductility requirements, may succeed in preventing building collapse during a severe earthquake, but at the expense of accepting a high damage level at the column bases. To improve the seismic performance of such buildings, different innovative techniques have been proposed. However, these have not been widely implemented in engineering practice due, among others, to the lack of simple conceptual design methodologies. To achieve this goal, a methodology for the design of a roof isolation system is presented, where the roof isolation serves as non-conventional tuned mass damper (TMD), giving a significantly reduced response in terms of displacements and forces. To that effect, design expressions for the TMD period and damping, depending on the building and soil characteristics, are proposed: The expressions have been calibrated based on numerical parametric time history analyses considering Eurocode 8 spectrum—compatible accelerograms. The application of the proposed methodology is demonstrated for a two-story prefabricated building.

[1]  Roberto Villaverde,et al.  Implementation Study of Aseismic Roof Isolation System in 13-Story Building , 2000 .

[2]  Fahim Sadek,et al.  A METHOD OF ESTIMATING THE PARAMETERS OF TUNED MASS DAMPERS FOR SEISMIC APPLICATIONS , 1997 .

[3]  Roberto Villaverde,et al.  Reduction seismic response with heavily-damped vibration absorbers , 1985 .

[4]  H. Tajimi,et al.  Statistical Method of Determining the Maximum Response of Building Structure During an Earthquake , 1960 .

[5]  R. Bouc Forced Vibration of Mechanical Systems with Hysteresis , 1967 .

[6]  T. T. Soong,et al.  Parametric study and simplified design of tuned mass dampers , 1998 .

[7]  Gilberto Mosqueda,et al.  Aseismic roof isolation system: analytic and shake table studies , 1999 .

[8]  Salvatore Perno,et al.  Dynamic response and optimal design of structures with large mass ratio TMD , 2012 .

[9]  M. Fardis,et al.  Designer's guide to EN 1998-1 and en 1998-5 Eurocode 8: Design of structures for earthquake resistance; general rules, seismic actions, design rules for buildings, foundations and retaining structures/ M.Fardis[et al.] , 2005 .

[10]  Hsiang-Chuan Tsai,et al.  Optimum tuned-mass dampers for minimizing steady-state response of support-excited and damped systems , 1993 .

[11]  Mikayel Melkumyan Experimental Investigation of Efficiency of Tuned Single and Double Mass Damper and its Application in the Form of an Additional Upper Floor for Seismic Protection of Existing Multistory Buildings , 2013 .

[12]  Roberto Villaverde,et al.  Roof Isolation System to Reduce the Seismic Response of Buildings: A Preliminary Assessment , 1998 .

[13]  James M. Kelly,et al.  Non‐classical damping in dynamic analysis of base‐isolated structures with internal equipment , 1988 .

[14]  K. V. Rama Rao,et al.  ( A STATE-OF-ART REPORT ) , 1988 .

[15]  Hsiang-Chuan Tsai,et al.  The effect of tuned-mass dampers on the seismic response of base-isolated structures , 1995 .

[16]  T. T. Soong,et al.  Recent structural applications of active control technology , 1994 .

[17]  Y. Wen Method for Random Vibration of Hysteretic Systems , 1976 .

[18]  Kiyoshi Kanai,et al.  Semi-empirical Formula for the Seismic Characteristics of the Ground , 1957 .

[19]  Yozo Fujino,et al.  Optimal tuned mass damper for seismic applications and practical design formulas , 2008 .

[20]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[21]  J. D. Holmes,et al.  Listing of installations , 1995 .

[22]  V. K. Koumousis,et al.  A Bouc–Wen model compatible with plasticity postulates , 2009 .

[23]  G. B. Warburton,et al.  Minimizing structural vibrations with absorbers , 1980 .