PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction

Over the course of diagnosis and treatment, it is common for a number of imaging studies to be acquired. Such imaging sequences can provide substantial patient-specific prior knowledge about the anatomy that can be incorporated into a prior-image-based tomographic reconstruction for improved image quality and better dose utilization. We present a general methodology using a model-based reconstruction approach including formulations of the measurement noise that also integrates prior images. This penalized-likelihood technique adopts a sparsity enforcing penalty that incorporates prior information yet allows for change between the current reconstruction and the prior image. Moreover, since prior images are generally not registered with the current image volume, we present a modified model-based approach that seeks a joint registration of the prior image in addition to the reconstruction of projection data. We demonstrate that the combined prior-image- and model-based technique outperforms methods that ignore the prior data or lack a noise model. Moreover, we demonstrate the importance of registration for prior-image-based reconstruction methods and show that the prior-image-registered penalized-likelihood estimation (PIRPLE) approach can maintain a high level of image quality in the presence of noisy and undersampled projection data.

[1]  Ali Mohammad-Djafari,et al.  Inversion of large-support ill-posed linear operators using a piecewise Gaussian MRF , 1998, IEEE Trans. Image Process..

[2]  Hui Yan,et al.  Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map. , 2012, International journal of radiation oncology, biology, physics.

[3]  Eun Sun Lee,et al.  Adaptive Statistical Iterative Reconstruction and Veo: Assessment of Image Quality and Diagnostic Performance in CT Colonography at Various Radiation Doses , 2012, Journal of computer assisted tomography.

[4]  Adam Wang,et al.  Joint estimation of deformation and penalized-likelihood CT reconstruction using previously acquired images , 2013 .

[5]  J. O’Sullivan,et al.  Properties of preprocessed sinogram data in x-ray computed tomography. , 2006, Medical physics.

[6]  Hakan Erdogan,et al.  Monotonic algorithms for transmission tomography , 2002, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[7]  Guang-Hong Chen,et al.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT. , 2012, Medical physics.

[8]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[9]  Jeffrey A. Fessler,et al.  Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.

[10]  J. Webster Stayman,et al.  Incorporation of noise and prior images in penalized-likelihood reconstruction of sparse data , 2012, Medical Imaging.

[11]  Guang-Hong Chen,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009, Medical physics.

[12]  P. Wolfe Convergence Conditions for Ascent Methods. II , 1969 .

[13]  Jeffrey A. Fessler,et al.  Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT , 2006, IEEE Transactions on Medical Imaging.

[14]  Christoph Thomas,et al.  Clinical evaluation and potential radiation dose reduction of the novel sinogram-affirmed iterative reconstruction technique (SAFIRE) in abdominal computed tomography angiography. , 2013, Academic radiology.

[15]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[16]  Curtis R. Vogel,et al.  Iterative Methods for Total Variation Denoising , 1996, SIAM J. Sci. Comput..

[17]  Bruce R Whiting,et al.  Statistical reconstruction for x-ray computed tomography using energy-integrating detectors , 2007, Physics in medicine and biology.

[18]  Jie Tang,et al.  Temporal resolution improvement using PICCS in MDCT cardiac imaging. , 2009 .

[19]  Joseph A O'Sullivan,et al.  Image reconstruction for transmission tomography when projection data are incomplete , 2006, Physics in medicine and biology.

[20]  Jie Tang,et al.  Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitions , 2009, Medical Imaging.

[21]  Jing Wang,et al.  High-quality four-dimensional cone-beam CT by deforming prior images. , 2013, Physics in medicine and biology.

[22]  Jingyan Xu,et al.  Electronic Noise Modeling in Statistical Iterative Reconstruction , 2009, IEEE Transactions on Image Processing.

[23]  B. Wilson,et al.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. , 2005, Medical physics.

[24]  Joshua D. Evans,et al.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms. , 2011, Medical physics.

[25]  R. White,et al.  Image recovery from data acquired with a charge-coupled-device camera. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[26]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[27]  Andrew Blake,et al.  Visual Reconstruction , 1987, Deep Learning for EEG-Based Brain–Computer Interfaces.

[28]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[29]  Guang-Hong Chen,et al.  Dose reduction using prior image constrained compressed sensing (DR-PICCS) , 2011, Medical Imaging.

[30]  Guang-Hong Chen,et al.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. , 2013, Medical physics.

[31]  M. Kachelriess,et al.  An investigation of 4D cone-beam CT algorithms for slowly rotating scanners. , 2010, Medical physics.

[32]  Jeffrey A. Fessler,et al.  3D Forward and Back-Projection for X-Ray CT Using Separable Footprints , 2010, IEEE Transactions on Medical Imaging.

[33]  Jorge Nocedal,et al.  On the limited memory BFGS method for large scale optimization , 1989, Math. Program..

[34]  Peter J. Huber,et al.  Robust Statistics , 2005, Wiley Series in Probability and Statistics.

[35]  S. Schafer,et al.  Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance. , 2011, Medical physics.

[36]  Steve B. Jiang,et al.  A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT , 2011, Physics in medicine and biology.

[37]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[38]  Guang-Hong Chen,et al.  Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm , 2012, IEEE Transactions on Medical Imaging.

[39]  David G. Luenberger,et al.  Linear and nonlinear programming , 1984 .

[40]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[41]  Jerry L. Prince,et al.  Penalized-likelihood reconstruction for sparse data acquisitions with unregistered prior images and compressed sensing penalties , 2011, Medical Imaging.

[42]  M. Unser,et al.  Interpolation revisited [medical images application] , 2000, IEEE Transactions on Medical Imaging.

[43]  Jeffrey A. Fessler,et al.  Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation , 2003 .

[44]  Hakan Erdogan,et al.  Monotonic algorithms for transmission tomography , 1999, IEEE Transactions on Medical Imaging.

[45]  Ken D. Sauer,et al.  A local update strategy for iterative reconstruction from projections , 1993, IEEE Trans. Signal Process..

[46]  Jerry L. Prince,et al.  Model-Based Tomographic Reconstruction of Objects Containing Known Components , 2012, IEEE Transactions on Medical Imaging.

[47]  B. De Man,et al.  Distance-driven projection and backprojection in three dimensions. , 2004, Physics in medicine and biology.

[48]  J H Siewerdsen,et al.  Model-based reconstruction of objects with inexactly known components , 2012, Medical Imaging.

[49]  Rebecca Fahrig,et al.  Dose and image quality for a cone-beam C-arm CT system. , 2006, Medical physics.

[50]  K. Lange Convergence of EM image reconstruction algorithms with Gibbs smoothing. , 1990, IEEE transactions on medical imaging.