Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power Generation System

A fault-tolerant technique of a grid-side converter (GSC) is a very important task because the unbalanced grid power endangers the overall system. Since the GSC is very sensitive to grid disturbance, the complete system needs to be stopped suddenly once an open-switch fault occurs. To improve the reliability of system, the continuous operation should be guaranteed. In this paper, a redundant topology based fault-tolerant algorithm is proposed for a GSC in a wind power generation system. The proposed scheme consists of the fault detection and fault-tolerant algorithms. The fault detection algorithm employs the durations of positive and negaitive cycles of three-phase grid currents as well as normalized root mean square (RMS) currents. Once a fault is detected, the corresponding faulty phase is identified and isolated to enable the fault-tolerant operation. The faulty phase is replaced by redundant one rapidly to recover the original shape of the grid currents, which ensures the continuity in operation. In contrast with the conventional methods, the proposed fault detection and fault-tolerant algorithms work effectively even in the presence of the open faults in multiple switches in the GSC. Simulation results verify the effectiveness of the proposed fault diagnosis and fault-tolerant control algorithms. Full Text: PDF DOI: http://dx.doi.org/10.11591/ijpeds.v6.i2.pp293-304

[1]  Demba Diallo,et al.  A fault-tolerant control architecture for induction motor drives in automotive applications , 2004, IEEE Transactions on Vehicular Technology.

[2]  Mario Marchesoni,et al.  A new fault tolerant NPC converter system for high power induction motor drives , 2011, 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives.

[3]  António J. Marques Cardoso,et al.  A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current Errors , 2013, IEEE Transactions on Industrial Electronics.

[4]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[5]  P. Mutschler,et al.  Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives , 2012, IEEE Transactions on Power Electronics.

[6]  Edison Roberto Cabral da Silva,et al.  Fault-tolerant voltage-fed PWM inverter AC motor drive systems , 2004, IEEE Transactions on Industrial Electronics.

[7]  Hirofumi Akagi,et al.  Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration , 2010, IEEE Transactions on Power Electronics.

[8]  Antonio J. Marques Cardoso,et al.  A new approach for real-time multiple open-circuit fault diagnosis in voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[9]  Li Ran,et al.  Fault-Tolerant Control for a Modular Generator–Converter Scheme for Direct-Drive Wind Turbines , 2011, IEEE Transactions on Industrial Electronics.

[10]  B. Justus Rabi Fault Tolerant Control in Z-Source Inverter Fed Induction Motor , 2011 .

[11]  Kyo-Beum Lee,et al.  Fault Diagnosis of a Voltage-Fed PWM Inverter for a Three-Parallel Power Conversion System in a Wind Turbine , 2010 .

[12]  Yantao Song,et al.  Analysis and Experimental Verification of a Fault-Tolerant HEV Powertrain , 2013, IEEE Transactions on Power Electronics.

[13]  Mohammad Reza Zolghadri,et al.  FPGA-Based Reconfigurable Control for Fault-Tolerant Back-to-Back Converter Without Redundancy , 2013, IEEE Transactions on Industrial Electronics.

[14]  Demba Diallo,et al.  Advanced Fault-Tolerant Control of Induction-Motor Drives for EV/HEV Traction Applications: From Conventional to Modern and Intelligent Control Techniques , 2007, IEEE Transactions on Vehicular Technology.

[15]  Zakaria Mohamed Salem,et al.  Performance Analysis of Field Orientation of Induction Motor Drive Under Open Gate of IGBT Fault , 2013 .

[16]  Demba Diallo,et al.  A Fuzzy-Based Approach for the Diagnosis of Fault Modes in a Voltage-Fed PWM Inverter Induction Motor Drive , 2008, IEEE Transactions on Industrial Electronics.

[17]  G. Venkataramanan,et al.  A Fault Tolerant Doubly Fed Induction Generator Wind Turbine Using a Parallel Grid Side Rectifier and Series Grid Side Converter , 2008, IEEE Transactions on Power Electronics.