Small Helical Flux Compression Amplifiers

Small, explosively compressed, magnetic flux transducers with many closely spaced helical turns are investigated theoretically and experimentally. The analysis is limited to linear operation, but takes into account load influence, proximity effects, and switching delays. The latter are due to retarded breakdown in the wire insulation and to the finite decay time of the magnetic field in the wire.