A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement.

Patient-specific cutting guides (PSCGs) are designed to improve the accuracy of alignment of total knee replacement (TKR). We compared the accuracy of limb alignment and component positioning after TKR performed using PSCGs or conventional instrumentation. A total of 80 patients were randomised to undergo TKR with either of the different forms of instrumentation, and radiological outcomes and peri-operative factors such as operating time were assessed. No significant difference was observed between the groups in terms of tibiofemoral angle or femoral component alignment. Although the tibial component in the PSCGs group was measurably closer to neutral alignment than in the conventional group, the size of the difference was very small (89.8° (sd 1.2) vs 90.5° (sd 1.6); p = 0.030). This new technology slightly shortened the bone-cutting time by a mean of 3.6 minutes (p < 0.001) and the operating time by a mean 5.1 minutes (p = 0.019), without tangible differences in post-operative blood loss (p = 0.528) or need for blood transfusion (p = 0.789). This study demonstrated that both PSCGs and conventional instrumentation restore limb alignment and place the components with the similar accuracy. The minimal advantages of PSCGs in terms of consistency of alignment or operative time are unlikely to be clinically relevant.

[1]  R. Barrack,et al.  Patient specific cutting blocks are currently of no proven value. , 2012, The Journal of bone and joint surgery. British volume.

[2]  M. Soudry,et al.  [Total knee arthroplasty]. , 1980, Harefuah.

[3]  Georg Matziolis,et al.  A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. , 2007, The Journal of bone and joint surgery. American volume.

[4]  P. Sharkey,et al.  Insall Award paper. Why are total knee arthroplasties failing today? , 2002, Clinical orthopaedics and related research.

[5]  Robert L. Barrack,et al.  Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[6]  Michael A. Mont,et al.  Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment , 2009, International Orthopaedics.

[7]  P. Lotke,et al.  Influence of positioning of prosthesis in total knee replacement. , 1977, The Journal of bone and joint surgery. American volume.

[8]  G. Engh,et al.  Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. , 1990, The Journal of arthroplasty.

[9]  Ning Liu,et al.  The value of patient-matched instrumentation in total knee arthroplasty. , 2012, The Journal of arthroplasty.

[10]  P. Sharkey,et al.  Why Are Total Knee Arthroplasties Failing Today? , 2002 .

[11]  A. Lombardi,et al.  Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA , 2012, Clinical orthopaedics and related research.

[12]  R. Barrack,et al.  Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[13]  Robert A Siston,et al.  Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. , 2008, Orthopedics.

[14]  William J Hozack,et al.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. , 2008, The Journal of arthroplasty.

[15]  M A Freeman,et al.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. , 1983, Clinical orthopaedics and related research.

[16]  John J. Callaghan,et al.  Orthopaedic knowledge update : hip and knee reconstruction , 1995 .

[17]  B. Morrey Navigated Total Knee Replacement: A Meta-Analysis , 2008 .

[18]  Joanne B. Adams,et al.  Patient-specific approach in total knee arthroplasty. , 2008, Orthopedics.

[19]  P. Boisrenoult,et al.  Pin track induced fractures around computer-assisted TKA. , 2010, Orthopaedics & traumatology, surgery & research : OTSR.

[20]  T. Fehring,et al.  Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. , 2007, The Journal of arthroplasty.

[21]  W. Breidahl,et al.  Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. , 2004, The Journal of bone and joint surgery. British volume.

[22]  K. Bozic,et al.  The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. , 2007, The Journal of bone and joint surgery. American volume.

[23]  M. Ritter,et al.  Postoperative alignment of total knee replacement. Its effect on survival. , 1994, Clinical orthopaedics and related research.

[24]  James D Slover,et al.  Cost-effectiveness analysis of custom total knee cutting blocks. , 2012, The Journal of arthroplasty.

[25]  R. Bryan,et al.  Total knee replacement. , 1981, Instructional course lectures.