Feasibility Study of Smartphone-Based Tear Volume Measurement System

Evaluation of tear volume is important for diagnosing dry eye disease. At the clinical site, dedicated devices such as slit lamp microscopy or Schirmer’s test strip have been used to quantify tear volume by ophthalmologist. However, these devices have access only in medical office and therefore have limited availability for the public. Tear volume changes with environmental, physical or psychological situation. For that reason, measurement of tear volume regardless of location, time or circumstances can be beneficial. In this study, a tear volume measurement system based on the principle of meniscometry was developed and implemented on the smartphone, and its feasibility was evaluated. It was shown that tear meniscus radii of 22 human subjects were calculated to be mean 0.31 (SD 0.06) mm which was within the range of the previous study. The results suggested the feasibility of tear volume measurement system using the smartphone based on the principle of meniscometry as an IoT sensor.

[1]  E. Papas,et al.  RELIABILITY OF THE WETTING VALUE OF TEARS , 1987, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[2]  Keith J Lane,et al.  The interblink interval in normal and dry eye subjects , 2013, Clinical ophthalmology.

[3]  A. Bron,et al.  Reflective meniscometry: a new field of dry eye assessment. , 2000, Cornea.

[4]  Murat Dogru,et al.  Concept of functional visual acuity and its applications. , 2007, Cornea.

[5]  James P. McCulley,et al.  Increased Evaporative Rates in Laboratory Testing Conditions Simulating Airplane Cabin Relative Humidity: An Important Factor for Dry Eye Syndrome , 2007, Eye & contact lens.

[6]  F. Holly Physical chemistry of the normal and disordered tear film. , 1985, Transactions of the ophthalmological societies of the United Kingdom.

[7]  J. Lee,et al.  Association between depression and dry eye disease in an elderly population. , 2011, Investigative ophthalmology & visual science.

[8]  P. Murphy,et al.  Comparison of a new portable digital meniscometer and optical coherence tomography in tear meniscus radius measurement , 2014, Acta ophthalmologica.

[9]  内野 美樹,et al.  Prevalence of dry eye disease among Japanese visual display terminal users , 2011 .

[10]  K. Tsubota,et al.  The importance of the Schirmer test with nasal stimulation. , 1991, American journal of ophthalmology.

[11]  A. Bron,et al.  Reflective meniscometry: a non-invasive method to measure tear meniscus curvature , 1999, The British journal of ophthalmology.

[12]  J. Mainstone,et al.  Tear meniscus measurement in the diagnosis of dry eye. , 1996, Current eye research.

[13]  Murat Dogru,et al.  Prevalence of dry eye disease among Japanese visual display terminal users. , 2008, Ophthalmology.

[14]  Mamoru Iwabuchi,et al.  Design and Implementation of Smartphone-Based Tear Volume Measurement System , 2016, HealthyIoT.

[15]  Paul J Murphy,et al.  A New Portable Digital Meniscometer , 2014, Optometry and vision science : official publication of the American Academy of Optometry.

[16]  R. Schiffman,et al.  Reliability and validity of the Ocular Surface Disease Index. , 2000, Archives of ophthalmology.