Effect of ultra-high molecular weight polyethylene thickness on contact mechanics in total knee replacement

Abstract One of the important design parameters in current knee joint replacements is the thickness of the ultra-high molecular weight polyethylene (UHMWPE) tibial insert, yet there is no clear definition of the upper limit of the ‘thick’ polyethylene insert. Using one design knee implant and subjecting it to the physiological loads encountered throughout the gait cycle, measurements of the lengths of contact imprints generated were compared with the corresponding theoretical predictions for different insert thicknesses under the same applied load. Multiple regression analysis was applied to test whether the dimensions of contact imprints are influenced by UHMWPE thickness. Good agreement was obtained between the theoretical predictions and the experimental measurements of the dimensions of contact imprints when the knee was at 60° flexion. Therefore, it was possible to estimate the contact pressure at the articulating surface using the theoretical model. Contact imprint dimensions increased with increasing applied load. Statistical analysis of the experimental data revealed that, at 0° flexion, the overall imprint dimensions increased as the UHMWPE thickness increased from 8 to 20 mm. However, the increment was not significant when the thickness subinterval 10-15 mm was considered. Furthermore, at 60° flexion, thickness was not a significant factor for the overall imprint dimensions. No evidence was found from the data to suggest that an increment in polyethylene thickness over 10 mm would significantly reduce the contact imprint dimensions. These findings suggest that thicker inserts can be avoided, as they require unnecessary bone resection.

[1]  P S Walker,et al.  Optimization of the bearing surface geometry of total knees. , 1994, Journal of biomechanics.

[2]  Morrison Jb Function of the knee joint in various activities. , 1969 .

[3]  G. Engh,et al.  Osteolysis after total knee arthroplasty without cement. , 1992, The Journal of bone and joint surgery. American volume.

[4]  D D Auger,et al.  Contact Pressure Prediction in Total Knee Joint Replacements Part 2: Application to the Design of Total Knee Joint replacements , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  R. Scott,et al.  Modular fixed-bearing total knee arthroplasty with retention of the posterior cruciate ligament. A study of patients followed for a minimum of fifteen years. , 2005, The Journal of bone and joint surgery. American volume.

[6]  J O Galante,et al.  Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[7]  D. Dowson,et al.  Contact Pressure Prediction in Total Knee Joint Replacements Part 1: General Elasticity Solution for Elliptical Layered Contacts , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[9]  D. Bartel,et al.  Stresses in polyethylene components of contemporary total knee replacements. , 1995, Clinical orthopaedics and related research.

[10]  R. E. Jensen,et al.  Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components , 1991, Clinical orthopaedics and related research.

[11]  P S Walker,et al.  The Deformation and Wear of Plastic Components in Artificial Knee Joints — An Experimental Study: , 1981 .

[12]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[13]  M. Freeman,et al.  Wear Particulate Species and Bone Loss in Failed Total Joint Arthroplasties , 1997, Clinical orthopaedics and related research.

[14]  T. Wright,et al.  Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. , 1992, Clinical orthopaedics and related research.

[15]  G. Engh,et al.  Tibial insert undersurface as a contributing source of polyethylene wear debris. , 1997, Clinical orthopaedics and related research.

[16]  C. G. Moran,et al.  Kinematic condylar total knee arthroplasty , 1996 .

[17]  I. Pinder,et al.  Kinematic condylar total knee arthroplasty. 14-year survivorship analysis of 208 consecutive cases. , 1996, The Journal of bone and joint surgery. British volume.

[18]  T. Andriacchi,et al.  A study of lower-limb mechanics during stair-climbing. , 1980, The Journal of bone and joint surgery. American volume.