CardioWest total artificial heart: Bad Oeynhausen experience.

BACKGROUND The use of ventricular assist devices (VAD) has become a widely accepted therapeutic option. However, there are still limitations to the patient collective eligible for VAD placement, who might therefore benefit from the implantation of a total artificial heart. We present the first German single-center experience with the CardioWest total artificial heart (TAH) (SynCardia Systems, Tucson, AZ) in 42 patients. METHODS Between February 2001 and December 2003, 42 patients (37 men, 5 women, mean age 51 +/- 13 years) received a TAH at our Center. Their body surface area ranged between 1.5 and 2.4 (mean, 1.9 +/- 0.19) m2. All patients were in persistent cardiogenic shock in spite of maximum inotropic support and had numerous preoperative risk factors (intraaortic balloon pumping, mechanical ventilation, acute renal failure, previous cardiac surgery, recent cardiopulmonary resuscitation). RESULTS Duration of support was 1 to 291 days. Eleven patients (26%) underwent successful transplantation; 9 of them could be discharged home. Twenty-two patients died under support, 21 of them from multiple organ failure and 1 patient from a technical problem. Nine patients are still on the device, 4 of them at home after the original CardioWest console was replaced by the Berlin Heart EXCOR driver (Berlin Heart, Berlin, Germany). Exceptional results were achieved in patients with cardiogenic shock after cardiac surgery or after acute myocardial infarction. CONCLUSIONS Against the background of the extremely poor preoperative situation of our patients, the overall survival rate of 48% can be considered as favorable. A prospective, randomized study is planned to find out whether patients with idiopathic dilated or ischemic cardiomyopathy are more likely to benefit from a biventricular assist device or a total artificial heart.

[1]  G. Tenderich,et al.  Device and patient management in a bridge-to-transplant setting. , 2001, The Annals of thoracic surgery.

[2]  J. Copeland,et al.  Comparison of the CardioWest total artificial heart, the novacor left ventricular assist system and the thoratec ventricular assist system in bridge to transplantation. , 2001, The Annals of thoracic surgery.

[3]  A. Pavie,et al.  Bridge to transplantation with the Jarvik-7 (CardioWest) total artificial heart: a single-center 15-year experience. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  Roland Hetzer,et al.  Permanent mechanical circulatory support in patients of advanced age. , 2004, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  C. Cabrol,et al.  Total Artificial Hearts , 1990 .

[6]  R. Benza,et al.  Infection in ventricular assist devices: prevention and treatment. , 2003, The Annals of thoracic surgery.

[7]  G. Tenderich,et al.  Predictors of survival in patients bridged to transplantation with the thoratec VAD device: a single-center retrospective study on more than 100 patients. , 2000, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[8]  F. Neumann,et al.  Cardiac release of cytokines and inflammatory responses in acute myocardial infarction. , 1995, Circulation.

[9]  Marvin J Slepian,et al.  Total artificial hearts: bridge to transplantation. , 2003, Cardiology clinics.

[10]  Marvin J Slepian,et al.  Cardiac replacement with a total artificial heart as a bridge to transplantation. , 2004, The New England journal of medicine.