Recent developments in electron‐resist evaluation techniques

A simple procedure for evaluating the performance of any positive electron resist is presented. SEM examination of the developed resist edge profile after electron‐beam exposure and development gives simultaneous information on resist sensitivity and resolution for a given resist thickness. This method gives a unique exposure charge‐density point for optimum resolution for a given resist system independent of developer strength.