Single Phase Voltage Source Inverter Photovoltaic Application

Photovoltaic applications have been developing and spreading rapidly in recent times. This paper describes the control strategy of the Voltage Source Inverter that is the important tail end of many photovoltaic applications.In order to supply the grid with a sinusoidal line current without harmonic distortion, the inverter is connected to the supply network via a L-C-L filter. The output current is controlled by the hysteresis controller. To improve the behaviors of the L-C-L filter, active damping of the filter is being used. This paper discusses controller design and simulation results.

[1]  S.V. Araujo,et al.  LCL filter design for grid-connected NPC inverters in offshore wind turbines , 2007, 2007 7th Internatonal Conference on Power Electronics.

[2]  Pekik Argo Dahono A method to damp oscillations on the input LC filter of current-type AC-DC PWM converters by using a virtual resistor , 2003, The 25th International Telecommunications Energy Conference, 2003. INTELEC '03..

[3]  Mutschler,et al.  Voltage source inverters for grid connected photovoltaic systems , 1998 .

[4]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).