Pseudo-CT Generation for MRI-Only Radiation Therapy Treatment Planning: Comparison Among Patch-Based, Atlas-Based, and Bulk Density Methods.

PURPOSE Methods have been recently developed to generate pseudo-computed tomography (pCT) for dose calculation in magnetic resonance imaging (MRI)-only radiation therapy. This study aimed to propose an original nonlocal mean patch-based method (PBM) and to compare this PBM to an atlas-based method (ABM) and to a bulk density method (BDM) for prostate MRI-only radiation therapy. MATERIALS AND METHODS Thirty-nine patients received a volumetric modulated arc therapy for prostate cancer. In addition to the planning computed tomography (CT) scans, T2-weighted MRI scans were acquired. pCTs were generated from MRIs using 3 methods: an original nonlocal mean PBM, ABM, and BDM. The PBM was performed using feature extraction and approximate nearest neighbor search in a training cohort. The PBM accuracy was evaluated in a validation cohort by using imaging and dosimetric endpoints. Imaging endpoints included mean absolute error and mean error between Hounsfield units of the pCT and the reference CT (CTref). Dosimetric endpoints were based on dose-volume histograms calculated from the CTref and the pCTs for various volumes of interest and on 3-dimensional gamma analyses. The PBM uncertainties were compared with those of the ABM and BDM. RESULTS The mean absolute error and mean error obtained from the PBM were 41.1 and -1.1 Hounsfield units. The PBM dose-volume histogram differences were 0.7% for prostate planning target volume V95%, 0.5% for rectum V70Gy, and 0.2% for bladder V50Gy. Compared with ABM and BDM, PBM provided significantly lower dose uncertainties for the prostate planning target volume (70-78 Gy), the rectum (8.5-29 Gy, 40-48 Gy, and 61-73 Gy), and the bladder (12-78 Gy). The PBM mean gamma pass rate (99.5%) was significantly higher than that of ABM (94.9%) or BDM (96.1%). CONCLUSIONS The proposed PBM provides low uncertainties with dose planned on CTref. These uncertainties were smaller than those of ABM and BDM and are unlikely to be clinically significant.

[1]  Fredrik Nordström,et al.  Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm. , 2015, Medical physics.

[2]  Alan Pollack,et al.  MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT. , 2004, International journal of radiation oncology, biology, physics.

[3]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[5]  T. Torfeh,et al.  Generation of synthetic CT using multi-scale and dual-contrast patches for brain MRI-only external beam radiotherapy. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[6]  Robert I McLachlan,et al.  The prevalence and diagnosis rates of Klinefelter syndrome: an Australian comparison , 2011, The Medical journal of Australia.

[7]  Daniel Rueckert,et al.  Patch-Based Segmentation without Registration: Application to Knee MRI , 2013, MLMI.

[8]  Koen Van Leemput,et al.  Cone beam computed tomography guided treatment delivery and planning verification for magnetic resonance imaging only radiotherapy of the brain , 2015, Acta oncologica.

[9]  Richard I. Hartley,et al.  Optimised KD-trees for fast image descriptor matching , 2008, 2008 IEEE Conference on Computer Vision and Pattern Recognition.

[10]  Koen Van Leemput,et al.  A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis. , 2016, Medical physics.

[11]  Tufve Nyholm,et al.  Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions , 2010, Radiation oncology.

[12]  A. Lin,et al.  Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planning , 2014, Journal of applied clinical medical physics.

[13]  Yaozong Gao,et al.  Estimating CT Image from MRI Data Using 3D Fully Convolutional Networks , 2016, LABELS/DLMIA@MICCAI.

[14]  Tiina Seppälä,et al.  A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer. , 2013, Medical physics.

[15]  C. Hennequin,et al.  Radiothérapie externe des cancers prostatiques , 2016 .

[16]  Olivier Salvado,et al.  A magnetic resonance imaging‐based workflow for planning radiation therapy for prostate cancer , 2011, The Medical journal of Australia.

[17]  Yaozong Gao,et al.  Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model , 2016, IEEE Transactions on Medical Imaging.

[18]  Du-Yih Tsai,et al.  Information Entropy Measure for Evaluation of Image Quality , 2008, Journal of Digital Imaging.

[19]  B G Fallone,et al.  A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions , 2008, Physics in medicine and biology.

[20]  Leonard Wee,et al.  Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images - Generalized technique for four different MR scanners. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  Jinsoo Uh,et al.  MRI-based treatment planning with pseudo CT generated through atlas registration. , 2014, Medical physics.

[22]  J. Edmund,et al.  A criterion for the reliable use of MRI-only radiotherapy , 2014, Radiation oncology.

[23]  Ming Dong,et al.  Generating synthetic CTs from magnetic resonance images using generative adversarial networks , 2018, Medical physics.

[24]  E. Yorke,et al.  Use of normal tissue complication probability models in the clinic. , 2010, International journal of radiation oncology, biology, physics.

[25]  Olivier Salvado,et al.  An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. , 2012, International journal of radiation oncology, biology, physics.

[26]  Mika Kapanen,et al.  T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning , 2013, Acta oncologica.

[27]  Jonathan J Wyatt,et al.  Systematic Review of Synthetic Computed Tomography Generation Methodologies for Use in Magnetic Resonance Imaging-Only Radiation Therapy. , 2018, International journal of radiation oncology, biology, physics.

[28]  Xiao Han,et al.  MR‐based synthetic CT generation using a deep convolutional neural network method , 2017, Medical physics.

[29]  Jeffrey P. Woodard,et al.  No-Reference image quality metrics for structural MRI , 2007, Neuroinformatics.

[30]  Olivier Salvado,et al.  MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  P. Maingon,et al.  70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial. , 2011, International journal of radiation oncology, biology, physics.

[32]  Sébastien Ourselin,et al.  Global image registration using a symmetric block-matching approach , 2014, Journal of medical imaging.

[33]  Polina Golland,et al.  Efficient Descriptor-Based Segmentation of Parotid Glands With Nonlocal Means , 2017, IEEE Transactions on Biomedical Engineering.

[34]  Jurgen Fripp,et al.  Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy , 2015, Medical Image Anal..

[35]  D Forsberg,et al.  Generating patient specific pseudo-CT of the head from MR using atlas-based regression , 2015, Physics in medicine and biology.

[36]  Jurgen Fripp,et al.  Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences. , 2015, International journal of radiation oncology, biology, physics.

[37]  Jelmer M. Wolterink,et al.  Deep MR to CT Synthesis Using Unpaired Data , 2017, SASHIMI@MICCAI.

[38]  Juha Korhonen,et al.  Dosimetric characterization of MRI-only treatment planning for brain tumors in atlas-based pseudo-CT images generated from standard T1-weighted MR images. , 2016, Medical physics.

[39]  Jason Dowling,et al.  Pseudo-CT generation by conditional inference random forest for MRI-based radiotherapy treatment planning , 2017, 2017 25th European Signal Processing Conference (EUSIPCO).

[40]  Su Ruan,et al.  Medical Image Synthesis with Context-Aware Generative Adversarial Networks , 2016, MICCAI.

[41]  Ninon Burgos,et al.  Robust CT Synthesis for Radiotherapy Planning: Application to the Head and Neck Region , 2015, MICCAI.

[42]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[43]  J. Edmund,et al.  Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain. , 2015, Medical physics.

[44]  Jelmer M. Wolterink,et al.  MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network. , 2018, International journal of radiation oncology, biology, physics.

[45]  Brian B. Avants,et al.  N4ITK: Improved N3 Bias Correction , 2010, IEEE Transactions on Medical Imaging.

[46]  Soumya Ghose,et al.  Regression and statistical shape model based substitute CT generation for MRI alone external beam radiation therapy from standard clinical MRI sequences , 2017, Physics in medicine and biology.

[47]  Ninon Burgos,et al.  Joint Segmentation and CT Synthesis for MRI-only Radiotherapy Treatment Planning , 2016, MICCAI.

[48]  Peter B. Greer,et al.  Structure-Guided Nonrigid Registration of CT-MR Pelvis Scans with Large Deformations in MR-Based Image Guided Radiation Therapy , 2013, CLIP.