Low dose CT reconstruction assisted by an image manifold prior.

X-ray Computed Tomography (CT) is an important tool in medical imaging to obtain a direct visualization of patient anatomy. However, the x-ray radiation exposure leads to the concern of lifetime cancer risk. Low-dose CT scan can reduce the radiation exposure to patient while the image quality is usually degraded due to the appearance of noise and artifacts. Numerous studies have been conducted to regularize CT image for better image quality. Yet, exploring the underlying manifold where real CT images residing on is still an open problem. In this paper, we propose a fully data-driven manifold learning approach by incorporating the emerging deep-learning technology. An encoder-decoder convolutional neural network has been established to map a CT image to the inherent low-dimensional manifold, as well as to restore the CT image from its corresponding manifold representation. A novel reconstruction algorithm assisted by the leant manifold prior has been developed to achieve high quality low-dose CT reconstruction. In order to demonstrate the effectiveness of the proposed framework, network training, testing, and comprehensive simulation study have been performed using patient abdomen CT images. The trained encoder-decoder CNN is capable of restoring high-quality CT images with average error of ~20 HU. Furthermore, the proposed manifold prior assisted reconstruction scheme achieves high-quality low-dose CT reconstruction, with average reconstruction error of < 30 HU, more than five times and two times lower than that of filtered back projection method and total-variation based iterative reconstruction method, respectively.

[1]  Claude Nahmias,et al.  Radiation Risk to Children From Computed Tomography , 2008, Pediatrics.

[2]  Steve B. Jiang,et al.  4D Computed Tomography Reconstruction from Few-Projection Data via Temporal Non-local Regularization , 2010, MICCAI.

[3]  Jing Wang,et al.  Nonlinear sinogram smoothing for low-dose X-ray CT , 2004, IEEE Transactions on Nuclear Science.

[4]  D. Brenner,et al.  Estimated risks of radiation-induced fatal cancer from pediatric CT. , 2001, AJR. American journal of roentgenology.

[5]  Xiaofei He,et al.  Locality Preserving Projections , 2003, NIPS.

[6]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[7]  Sergey Ioffe,et al.  Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift , 2015, ICML.

[8]  Steve B. Jiang,et al.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation. , 2010, Medical physics.

[9]  Bin Dong,et al.  X-Ray CT Image Reconstruction via Wavelet Frame Based Regularization and Radon Domain Inpainting , 2013, J. Sci. Comput..

[10]  Jing Wang,et al.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography , 2006, IEEE Transactions on Medical Imaging.

[11]  Gabor T. Herman,et al.  Fundamentals of Computerized Tomography: Image Reconstruction from Projections , 2009, Advances in Pattern Recognition.

[12]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[13]  Maximilian F. Reiser,et al.  Noise/dose reduction and image improvements in screening virtual colonoscopy with tube currents of 20 mAs with nonlinear Gaussian filter chains , 2002, SPIE Medical Imaging.

[14]  Geoffrey E. Hinton,et al.  Guest Editorial: Deep Learning , 2015, International Journal of Computer Vision.

[15]  Roger C. Tam,et al.  Manifold Learning of Brain MRIs by Deep Learning , 2013, MICCAI.

[16]  G. Moneta,et al.  Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 , 2010 .

[17]  Ronald M. Summers,et al.  Deep Learning in Medical Imaging: Overview and Future Promise of an Exciting New Technique , 2016 .

[18]  Zhengrong Liang,et al.  Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters , 2005, SPIE Medical Imaging.

[19]  Varda Shalev,et al.  Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children. , 2007, The Israel Medical Association journal : IMAJ.

[20]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[21]  Stephen M. Moore,et al.  The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository , 2013, Journal of Digital Imaging.

[22]  Herbert F. Voigt,et al.  IEEE Engineering in Medicine and Biology Society , 2019, IEEE Transactions on Biomedical Engineering.

[23]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[24]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[25]  King-Sun Fu,et al.  IEEE Transactions on Pattern Analysis and Machine Intelligence Publication Information , 2004, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[26]  Steve B. Jiang,et al.  Low-dose 4DCT reconstruction via temporal nonlocal means. , 2010, Medical physics.

[27]  Jing Wang,et al.  Automatic PET cervical tumor segmentation by deep learning with prior information , 2018, Medical Imaging.

[28]  D. Miglioretti,et al.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. , 2009, Archives of internal medicine.

[29]  K Sauer,et al.  Nonstationary filtering of transmission tomograms in high photon counting noise. , 1991, IEEE transactions on medical imaging.

[30]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[31]  Jong Chul Ye,et al.  Deep residual learning for compressed sensing MRI , 2017, 2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017).

[32]  Zhengrong Liang,et al.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space , 2008, Physics in medicine and biology.

[33]  Yuan Yu,et al.  TensorFlow: A system for large-scale machine learning , 2016, OSDI.

[34]  Jong Chul Ye,et al.  Deep Residual Learning for Compressed Sensing CT Reconstruction via Persistent Homology Analysis , 2016, ArXiv.

[35]  Yuxiao Hu,et al.  Face recognition using Laplacianfaces , 2005, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[36]  P. L. La Riviere Penalized-likelihood sinogram smoothing for low-dose CT. , 2005, Medical physics.

[37]  Omer Demirkaya Reduction of noise and image artifacts in computed tomography by nonlinear filtration of projection images , 2001, SPIE Medical Imaging.

[38]  Alexei A. Efros,et al.  Generative Visual Manipulation on the Natural Image Manifold , 2016, ECCV.

[39]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[40]  Steve B. Jiang,et al.  GPU-based iterative cone-beam CT reconstruction using tight frame regularization , 2010, Physics in medicine and biology.

[41]  OsherStanley,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[42]  Steve B. Jiang,et al.  Intelligent Parameter Tuning in Optimization-Based Iterative CT Reconstruction via Deep Reinforcement Learning , 2017, IEEE Transactions on Medical Imaging.

[43]  Geoffrey E. Hinton,et al.  Rectified Linear Units Improve Restricted Boltzmann Machines , 2010, ICML.