Discrete-time Integral Sliding Mode Control of a smart joint for minimally invasive surgeries

In this work, a shape memory alloy(SMA) actuator based joint (smart joint) is controlled using a discrete-time integral sliding mode (DISM) control to guide the motion of an active catheter. Controller is designed on the base of a simplified physical model of a single SMA actuator which eliminates the necessity of obtaining an accurate model. SMAs are nonlinear actuators and for this reason, a disturbance observer (DOB) is integrated in to the controller to compensate the model uncertainties and external disturbances to the system. A linearized model is used to design the controller. Bandwidth of SMA actuator is small (response frequency is less than 0.1Hz) and hardware communication frequency is 20Hz. Due to high sampling time (τ= 50ms) it is idealized to design a discrete-time controller, as switching frequency of the controller variable is then limited by τ-1. An experimental setup is designed to test the proposed controller with position feedback. In experimental results, DISM controller with DOB is shown to be robust against system model uncertainties and external disturbances. Different frequency responses are compared and it is shown that the response of 0.04 Hz can be achieved with rms tracking error of 0.0112 radians.

[1]  Craig A. Rogers,et al.  One-Dimensional Thermomechanical Constitutive Relations for Shape Memory Materials , 1990 .

[2]  Jian-Xin Xu,et al.  On the Discrete-Time Integral Sliding Mode Control , 2006 .

[3]  Xinghuo Yu,et al.  On the Discrete-Time Integral Sliding-Mode Control , 2007, IEEE Transactions on Automatic Control.

[4]  K. Tanaka A THERMOMECHANICAL SKETCH OF SHAPE MEMORY EFFECT: ONE-DIMENSIONAL TENSILE BEHAVIOR , 1986 .

[5]  F. Kuhn,et al.  Long-term outcome analysis of balloon catheter sinusotomy: Two-year follow-up , 2008, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[6]  Koji Ikuta,et al.  Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[7]  A. Abreu,et al.  Pulmonary Artery Rupture Induced by a Pulmonary Artery Catheter: A Case Report and Review of the Literature , 2004, Journal of intensive care medicine.

[8]  Craig A. Rogers,et al.  One-Dimensional Thermomechanical Constitutive Relations for Shape Memory Materials , 1990 .

[9]  Rajnikant V. Patel,et al.  Modeling and Control of Shape Memory Alloy Actuators , 2008, IEEE Transactions on Control Systems Technology.

[10]  L. C. Brinson,et al.  Simplifications and Comparisons of Shape Memory Alloy Constitutive Models , 1996 .

[11]  Jaydev P. Desai,et al.  Towards a discretely actuated steerable cannula , 2012, 2012 IEEE International Conference on Robotics and Automation.

[12]  Roy Featherstone,et al.  Improving the Speed of Shape Memory Alloy Actuators by Faster Electrical Heating , 2004, ISER.

[13]  J.L. Pons,et al.  Comparison of different control approaches to drive SMA actuators , 1997, 1997 8th International Conference on Advanced Robotics. Proceedings. ICAR'97.

[14]  L. Brinson One-Dimensional Constitutive Behavior of Shape Memory Alloys: Thermomechanical Derivation with Non-Constant Material Functions and Redefined Martensite Internal Variable , 1993 .