A New Non-Negative Matrix Co-Factorisation Approach for Noisy Neonatal Chest Sound Separation

Obtaining high quality heart and lung sounds enables clinicians to accurately assess a newborns cardio-respiratory health and provide timely care. However, noisy chest sound recordings are common, hindering timely and accurate assessment. A new Non-negative Matrix Co-Factorisation based approach is proposed to separate noisy chest sound recordings into heart, lung and noise components to address this problem. This method is achieved through training with 20 high quality heart and lung sounds, in parallel with separating the sounds of the noisy recording. The method was tested on 68 10-second noisy recordings containing both heart and lung sounds and compared to the current state of the art Non-negative Matrix Factorisation methods. Results show significant improvements in heart and lung sound quality scores respectively, and improved accuracy of 3.6bpm and 1.2bpm in heart and breathing rate estimation respectively, when compared to existing methods.

[1]  Faezeh Marzbanrad,et al.  Digital stethoscopes in paediatric medicine , 2019, Acta paediatrica.

[2]  Tiago H. Falk,et al.  Modulation filtering for heart and lung sound separation from breath sound recordings , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Constantinos B. Papadias,et al.  On the Blind Recovery of Cardiac and Respiratory Sounds , 2015, IEEE Journal of Biomedical and Health Informatics.

[4]  ChingShun Lin,et al.  Blind source separation of heart and lung sounds based on nonnegative matrix factorization , 2013, 2013 International Symposium on Intelligent Signal Processing and Communication Systems.

[5]  A. Malhotra,et al.  Acoustic analysis of neonatal breath sounds using digital stethoscope technology , 2020, Pediatric pulmonology.

[6]  Amir Lahav,et al.  Questionable sound exposure outside of the womb: frequency analysis of environmental noise in the neonatal intensive care unit , 2015, Acta paediatrica.

[7]  A. Malhotra,et al.  Tools to assess lung aeration in neonates with respiratory distress syndrome , 2020, Acta paediatrica.

[8]  Saeid Sanei,et al.  Separation of heart sound signal from lung sound signal by adaptive line enhancement , 2007, 2007 15th European Signal Processing Conference.

[9]  E. Bancalari,et al.  Neonatal monitoring during delivery room emergencies. , 2019, Seminars in fetal & neonatal medicine.

[10]  Hamid Reza Mohseni,et al.  Localizing Heart Sounds in Respiratory Signals Using Singular Spectrum Analysis , 2011, IEEE Transactions on Biomedical Engineering.

[11]  Pedro Vera-Candeas,et al.  Wheezing Sound Separation Based on Informed Inter-Segment Non-Negative Matrix Partial Co-Factorization , 2020, Sensors.

[12]  R. Roseby,et al.  Digital stethoscopes compared to standard auscultation for detecting abnormal paediatric breath sounds , 2017, European Journal of Pediatrics.

[13]  A. Malhotra,et al.  Assessment of breath sounds at birth using digital stethoscope technology , 2019, European Journal of Pediatrics.

[14]  January Gnitecki,et al.  Separating heart sounds from lung sounds. Accurate diagnosis of respiratory disease depends on understanding noises. , 2007, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[15]  Guy A. Dumont,et al.  Neonatal Heart and Lung Sound Quality Assessment for Robust Heart and Breathing Rate Estimation for Telehealth Applications , 2020, IEEE Journal of Biomedical and Health Informatics.

[16]  W. Hager,et al.  and s , 2019, Shallow Water Hydraulics.

[17]  Nicolás Ruiz-Reyes,et al.  A non-negative matrix factorization approach based on spectro-temporal clustering to extract heart sounds , 2017 .

[18]  Ruban Nersisson,et al.  Heart sound and lung sound separation algorithms: a review , 2017, Journal of medical engineering & technology.

[19]  W. Marsden I and J , 2012 .

[20]  Le Roux Sparse NMF – half-baked or well done? , 2015 .

[21]  R. Sarpong,et al.  Bio-inspired synthesis of xishacorenes A, B, and C, and a new congener from fuscol† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c9sc02572c , 2019, Chemical science.

[22]  Zahra Moussavi,et al.  An overview of heart-noise reduction of lung sound using wavelet transform based filter , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).