Synthetic quantitative MRI through relaxometry modelling

Quantitative MRI (qMRI) provides standardized measures of specific physical parameters that are sensitive to the underlying tissue microstructure and are a first step towards achieving maps of biologically relevant metrics through in vivo histology using MRI. Recently proposed models have described the interdependence of qMRI parameters. Combining such models with the concept of image synthesis points towards a novel approach to synthetic qMRI, in which maps of fundamentally different physical properties are constructed through the use of biophysical models. In this study, the utility of synthetic qMRI is investigated within the context of a recently proposed linear relaxometry model. Two neuroimaging applications are considered. In the first, artefact‐free quantitative maps are synthesized from motion‐corrupted data by exploiting the over‐determined nature of the relaxometry model and the fact that the artefact is inconsistent across the data. In the second application, a map of magnetization transfer (MT) saturation is synthesized without the need to acquire an MT‐weighted volume, which directly leads to a reduction in the specific absorption rate of the acquisition. This feature would be particularly important for ultra‐high field applications. The synthetic MT map is shown to provide improved segmentation of deep grey matter structures, relative to segmentation using T1‐weighted images or R1 maps. The proposed approach of synthetic qMRI shows promise for maximizing the extraction of high quality information related to tissue microstructure from qMRI protocols and furthering our understanding of the interrelation of these qMRI parameters.

[1]  K. Uğurbil,et al.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo , 2007, Magnetic resonance in medicine.

[2]  P P Fatouros,et al.  In Vivo Brain Water Determination by T1 Measurements: Effect of Total Water Content, Hydration Fraction, and Field Strength , 1991, Magnetic resonance in medicine.

[3]  N. Gelman,et al.  Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: Relation to estimated iron and water contents , 2001, Magnetic resonance in medicine.

[4]  Daniel S. Margulies,et al.  Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping , 2014, Front. Neurosci..

[5]  Robert Turner,et al.  Image Distortion Correction in fMRI: A Quantitative Evaluation , 2002, NeuroImage.

[6]  R. Deichmann,et al.  Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles , 2009, Magnetic resonance in medicine.

[7]  M. A. Basso,et al.  The basal ganglia: An overview of circuits and function , 2008, Neuroscience & Biobehavioral Reviews.

[8]  P. Dechent,et al.  Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation , 2008, Magnetic resonance in medicine.

[9]  Richard S. Frackowiak,et al.  Disentangling in vivo the effects of iron content and atrophy on the ageing human brain , 2014, NeuroImage.

[10]  Peter Dechent,et al.  Modeling the influence of TR and excitation flip angle on the magnetization transfer ratio (MTR) in human brain obtained from 3D spoiled gradient echo MRI , 2010, Magnetic resonance in medicine.

[11]  Dan Rettmann,et al.  PROMO: Real‐time prospective motion correction in MRI using image‐based tracking , 2010, Magnetic resonance in medicine.

[12]  J N Lee,et al.  Pulse sequence extrapolation with MR image synthesis. , 1986, Radiology.

[13]  Vikas Gulani,et al.  Towards a Single-Sequence Neurologic Magnetic Resonance Imaging Examination: Multiple-Contrast Images From an IR TrueFISP Experiment , 2004, Investigative radiology.

[14]  Thomas H. B. FitzGerald,et al.  Widespread age-related differences in the human brain microstructure revealed by quantitative magnetic resonance imaging , 2014, Neurobiology of Aging.

[15]  U. Klose,et al.  The in vivo influence of white matter fiber orientation towards B0 on T2* in the human brain , 2010, NMR in biomedicine.

[16]  Nikolaus Weiskopf,et al.  Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation , 2013, Front. Neurosci..

[17]  Karl J. Friston,et al.  Statistical parametric mapping , 2013 .

[18]  Nikolaus Weiskopf,et al.  An evaluation of prospective motion correction (PMC) for high resolution quantitative MRI , 2015, Front. Neurosci..

[19]  P. Batchelor,et al.  Matrix description of general motion correction applied to multishot images , 2005, Magnetic resonance in medicine.

[20]  Clifford R. Jack,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2001, SPIE Medical Imaging.

[21]  O Smedby,et al.  Synthetic Mri of the Brain in a Clinical Setting , 2012, Acta radiologica.

[22]  Robert Turner,et al.  Myelin and iron concentration in the human brain: A quantitative study of MRI contrast , 2014, NeuroImage.

[23]  P. Lundberg,et al.  Rapid magnetic resonance quantification on the brain: Optimization for clinical usage , 2008, Magnetic resonance in medicine.

[24]  J. Gore,et al.  Compartmental study of T1 and T2 in rat brain and trigeminal nerve in vivo , 2002, Magnetic resonance in medicine.

[25]  F. Dick,et al.  Whole-Brain In-vivo Measurements of the Axonal G-Ratio in a Group of 37 Healthy Volunteers , 2015, Front. Neurosci..

[26]  P. Dechent,et al.  Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T , 2009, Journal of magnetic resonance imaging : JMRI.

[27]  A. Dale,et al.  Prospective motion correction improves diagnostic utility of pediatric MRI scans , 2011, Pediatric Radiology.

[28]  Ralf Deichmann,et al.  Improved visibility of brain tumors in synthetic MP‐RAGE anatomies with pure T1 weighting , 2015, NMR in biomedicine.

[29]  C. D. De Dreu,et al.  Oxytocin-Motivated Ally Selection is Moderated by Fetal Testosterone Exposure and Empathic Concern , 2012, Front. Neurosci..

[30]  John Ashburner,et al.  A fast diffeomorphic image registration algorithm , 2007, NeuroImage.

[31]  S J Riederer,et al.  Image metric‐based correction (Autocorrection) of motion effects: Analysis of image metrics , 2000, Journal of magnetic resonance imaging : JMRI.

[32]  David H. Miller,et al.  Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain , 2004, Annals of neurology.

[33]  Xin Li,et al.  A unified magnetic resonance imaging pharmacokinetic theory: Intravascular and extracellular contrast reagents , 2005, Magnetic resonance in medicine.

[34]  Gunther Helms,et al.  Tissue Properties from Quantitative MRI , 2015 .

[35]  Andrea Bergmann,et al.  Statistical Parametric Mapping The Analysis Of Functional Brain Images , 2016 .

[36]  W. Brittin,et al.  Nuclear Magnetic Resonance Studies in Multiple Phase Systems: Lifetime of a Water Molecule in an Adsorbing Phase on Silica Gel , 1957 .

[37]  Nikolaus Weiskopf,et al.  Estimating the apparent transverse relaxation time (R2*) from images with different contrasts (ESTATICS) reduces motion artifacts , 2014, Front. Neurosci..

[38]  R Turner,et al.  Optimisation of the 3D MDEFT sequence for anatomical brain imaging: technical implications at 1.5 and 3 T , 2004, NeuroImage.

[39]  Matti Hämäläinen,et al.  Brain Mapping: An Encyclopedic Reference , 2015 .

[40]  A. Lutti,et al.  Advances in MRI-based computational neuroanatomy: from morphometry to in-vivo histology. , 2015, Current opinion in neurology.

[41]  Ralf Deichmann,et al.  Quantitative proton density mapping: correcting the receiver sensitivity bias via pseudo proton densities , 2012, NeuroImage.

[42]  Karl J. Friston,et al.  Unified segmentation , 2005, NeuroImage.

[43]  P. Dechent,et al.  High‐resolution maps of magnetization transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI , 2008, Magnetic resonance in medicine.

[44]  André J W van der Kouwe,et al.  Real‐time rigid body motion correction and shimming using cloverleaf navigators , 2006, Magnetic resonance in medicine.

[45]  J L Potter,et al.  NMR relaxation of protons in tissues and other macromolecular water solutions. , 1982, Magnetic resonance imaging.

[46]  S. Ropele,et al.  Quantitative MR imaging of brain iron: a postmortem validation study. , 2010, Radiology.

[47]  Richard S. Frackowiak,et al.  Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter maps , 2009, NeuroImage.

[48]  A. Lutti,et al.  A General Linear Relaxometry Model of R1 Using Imaging Data , 2014, Magnetic resonance in medicine.

[49]  J. Finsterbusch,et al.  Optimization and Validation of Methods for Mapping of the Radiofrequency Transmit Field at 3T , 2010, Magnetic resonance in medicine.

[50]  O. Josephs,et al.  Robust and Fast Whole Brain Mapping of the RF Transmit Field B1 at 7T , 2012, PloS one.

[51]  J G Pipe,et al.  PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion , 2001, Journal of magnetic resonance imaging : JMRI.