Computerized analysis of the effects of intraocular lens edge design on the quality of vision in pseudophakic patients

Purpose: To study the distribution and intensity of reflected glare images from 3 intraocular lens (IOL) edge designs. Setting: Eye Institute, University of Florence, Florence, Italy. Methods: The interaction of light rays as a function of edge design was evaluated using an experimental eye model and an advanced ray‐tracing program. Three hydrophobic acrylic IOLs were studied: an acrylic square‐edged (sharp) design, an acrylic round‐edged design, and a new acrylic IOL with a rounded anterior edge and a sharp posterior edge. Results: The rays hitting the sharp edge of an IOL caused peripheral arcs or circles of light on the side of the retina opposite the focused image. Edge reflections also occurred with the round‐edged IOL, but the intensity of the reflected image was one tenth that of the intensity with the sharp‐edged design. The new round‐/sharp‐edged design reduced the maximum intensity of the reflected image to one third the intensity of the sharp‐edged reflected image. Conclusions: The experimental findings with an acrylic IOL that combines a sharp posterior edge with a low incidence of reflected edge glare are promising.

[1]  O. Nishi,et al.  Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. , 1999, Journal of cataract and refractive surgery.

[2]  D. Leaming Practice styles and preferences of ASCRS members—1999 survey , 2000, Journal of cataract and refractive surgery.

[3]  J T Holladay,et al.  Analysis of edge glare phenomena in intraocular lens edge designs. , 1999, Journal of cataract and refractive surgery.

[4]  J. Gills Foldable Intraocular Lenses—Evolution Clinicopathologic Correlations, and Complications. David J. Apple, Gerd U. Auffarth, Gun Peng, and Nithi Visessook. SLACK Incorporated, 2000. 288 pages. $95.00 , 2001 .

[5]  O. Nishi,et al.  Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. , 1998, Ophthalmic surgery and lasers.

[6]  J. Davison Positive and negative dysphotopsia in patients with acrylic intraocular lenses , 2000, Journal of cataract and refractive surgery.

[7]  J. Lewis,et al.  Diagnosis and treatment of mysterious light streaks seen by patients following extracapsular cataract extraction. , 1985, Journal - American Intra-Ocular Implant Society.

[8]  A. Kruger,et al.  Two year results: sharp versus rounded optic edges on silicone lenses , 2000, Journal of cataract and refractive surgery.

[9]  D. Apple,et al.  Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. , 2001, Ophthalmology.

[10]  M. Samore,et al.  Dysphotopsia in phakic and pseudophakic patients: incidence and relation to intraocular lens type , 2000, Journal of cataract and refractive surgery.

[11]  D. Apple,et al.  Surgical prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense. , 2000, Journal of cataract and refractive surgery.

[12]  A. Crandall,et al.  Visual complaints associated with the AcrySof acrylic intraocular lens , 2000, Journal of cataract and refractive surgery.

[13]  H. Ahmadieh,et al.  Intra-ocular lens implantation in children , 2001, Current opinion in ophthalmology.

[14]  G. Vrensen,et al.  Cell biology of posterior capsular opacification , 1999, Eye.

[15]  S. Masket,et al.  Undesired light images associated with ovoid intraocular lenses , 1993, Journal of cataract and refractive surgery.

[16]  O. Nishi,et al.  Effect of round‐edged acrylic intraocular lenses on preventing posterior capsule opacification , 2001, Journal of cataract and refractive surgery.

[17]  D. Sanders,et al.  Foldable Intraocular Lenses , 1993 .

[18]  K. Wickström,et al.  Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges , 2000, Journal of cataract and refractive surgery.

[19]  D. Apple,et al.  Surgical prevention of posterior capsule opacification. Part 1: Progress in eliminating this complication of cataract surgery. , 2000, Journal of cataract and refractive surgery.