Comparison of a priori calibration models for respiratory inductance plethysmography during running

Respiratory inductive plethysmography (RIP) has been introduced as an alternative for measuring ventilation by means of body surface displacement (diameter changes in rib cage and abdomen). Using a posteriori calibration, it has been shown that RIP may provide accurate measurements for ventilatory tidal volume under exercise conditions. Methods for a priori calibration would facilitate the application of RIP. Currently, to the best knowledge of the authors, none of the existing ambulant procedures for RIP calibration can be used a priori for valid subsequent measurements of ventilatory volume under exercise conditions. The purpose of this study is to develop and validate a priori calibration algorithms for ambulant application of RIP data recorded in running exercise. We calculated Volume Motion Coefficients (VMCs) using seven different models on resting data and compared the root mean squared error (RMSE) of each model applied on running data. Least squares approximation (LSQ) without offset of a two-degree-of-freedom model achieved the lowest RMSE value. In this work, we showed that a priori calibration of RIP exercise data is possible using VMCs calculated from 5 min resting phase where RIP and flowmeter measurements were performed simultaneously. The results demonstrate that RIP has the potential for usage in ambulant applications.

[1]  R. Gonzalez Applied Multivariate Statistics for the Social Sciences , 2003 .

[2]  G. W. Snedecor Statistical Methods , 1964 .

[3]  Heike Leutheuser,et al.  Respiratory inductance plethysmography-a rationale for validity during exercise. , 2014, Medicine and science in sports and exercise.

[4]  J M Kinney,et al.  Effects of respiratory apparatus on breathing pattern. , 1980, Journal of applied physiology: respiratory, environmental and exercise physiology.

[5]  Martin Brutsche,et al.  Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life , 2010, Biological Psychology.

[6]  John Staudenmayer,et al.  Improved regression models for ventilation estimation based on chest and abdomen movements , 2012, Physiological measurement.

[7]  A. Sheel,et al.  Measurement of exercise ventilation by a portable respiratory inductive plethysmograph , 2006, Respiratory Physiology & Neurobiology.

[8]  K. Bloch,et al.  Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph. , 2005, Chest.

[9]  Bernhard Schölkopf,et al.  A tutorial on support vector regression , 2004, Stat. Comput..

[10]  M A Sackner,et al.  Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph. I. , 1980, The American review of respiratory disease.

[11]  H J Green,et al.  A computer linear regression model to determine ventilatory anaerobic threshold. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[12]  Marvin A. Sackner,et al.  Non-invasive Measurement of Ventilation During Exercise Using A Respiratory Inductive Plethysmograph. I.1–3 , 2015 .

[13]  J. Mead,et al.  Measurement of the separate volume changes of rib cage and abdomen during breathing. , 1967, Journal of applied physiology.

[14]  B. Krieger,et al.  Calibration of respiratory inductive plethysmograph during natural breathing. , 1989, Journal of applied physiology.

[15]  J H Auchincloss,et al.  Changes in tidal volume, frequency, and ventilation induced by their measurement. , 1972, Journal of applied physiology.

[16]  J. Stocks,et al.  Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants. , 1998, The European respiratory journal.

[17]  Frank H Wilhelm,et al.  The LifeShirt , 2003, Behavior modification.

[18]  Konrad E. Bloch,et al.  Respiratory Monitoring by Inductive Plethysmography in Unrestrained Subjects Using Position Sensor-Adjusted Calibration , 2009, Respiration.

[19]  M. Sackner,et al.  Validation of respiratory inductive plethysmography using different calibration procedures. , 2015, The American review of respiratory disease.

[20]  A. Atiya,et al.  Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond , 2005, IEEE Transactions on Neural Networks.

[21]  Shahriar Gharibzadeh,et al.  Nonlinear model for estimating respiratory volume based on thoracoabdominal breathing movements , 2013, Respirology.