Total knee arthroplasty three-dimensional kinematic estimation prevision. From a two-dimensional fluoroscopy acquired dynamic model.

INTRODUCTION To determine six-degree of freedom of total knee arthroplasty kinematics (TKA), optimized matching algorithms for single fluoroscopic image system may be used. Theoretical accuracy of these systems was reported. Nevertheless, all reports were done under idealized laboratory experimental conditions. The aim of this study was to evaluate the "true" accuracy of a flat panel single plane video-fluoroscopy system based on computed-assisted design (CAD) model matching and compare it to TKA kinematics obtained from optoelectronic measurements as gold standard. HYPOTHESIS The estimation of the error produced by 2D/3D fluoroscopic registration in daily practice is misjudged in most available laboratory reports. MATERIAL AND METHODS The experimental set-up used a TKA implanted into femoral and tibial cadaver bones. Thirty flexions were simultaneously registered using single plane fluoroscopy and an active optical tracking system. Kinematics registered were compared using the root mean square error (RMS), the concordance correlation coefficient and Bland & Altman plot analysis. RESULTS The mean range of motion of flexion during the experiment was 106°. The respective RMS for flexion, varus-valgus and internal-external rotation were 0.68, 0.67 and 1.02°. The respective RMS for antero-posterior, medio-lateral and proximo-distal displacement were 1.3, 2.4 and 1.06 mm. Extreme values of the measured error concerning medio-lateral displacement were -5.4 and 22,1mm. DISCUSSIONS Analysis found some outliners in all degree of freedom with a systematic error and larger standard deviation than already published data. One should make sure that during the experiment the motion of interest is in the in-plane direction. Moreover, this study brings out the true threshold detection of this type of analysis.

[1]  J B Stiehl,et al.  In vivo kinematic analysis of a mobile bearing total knee prosthesis. , 1997, Clinical orthopaedics and related research.

[2]  PIETER M. J. VAN DER ZWET,et al.  Automated and Accurate Assessment of the Distribution, Magnitude, and Direction of Pincushion Distortion in Angiographic Images , 1995, Investigative radiology.

[3]  Guoan Li,et al.  Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. , 2004, Journal of biomechanical engineering.

[4]  A Ishida,et al.  A simple radiographic measurement method for polyethylene wear in total knee arthroplasty. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[5]  Scott Tashman,et al.  In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: Application to knee kinematics , 2001, IEEE Transactions on Medical Imaging.

[6]  C. Spoor,et al.  Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.

[7]  Guoan Li,et al.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. , 2006, Journal of biomechanical engineering.

[8]  E. Gronenschild,et al.  Correction for geometric image distortion in the x-ray imaging chain: local technique versus global technique. , 1999, Medical physics.

[9]  T P Andriacchi,et al.  A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. , 1998, Journal of biomechanical engineering.

[10]  Bart L Kaptein,et al.  Marker Configuration Model-Based Roentgen Fluoroscopic Analysis. , 2005, Journal of biomechanics.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  S.A. Banks,et al.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy , 1996, IEEE Transactions on Biomedical Engineering.

[13]  Alberto Leardini,et al.  A model-based method for the reconstruction of total knee replacement kinematics , 1999, IEEE Transactions on Medical Imaging.

[14]  J. Tamura,et al.  In Vivo Three-Dimensional Knee Kinematics Using a Biplanar Image-Matching Technique , 2001, Clinical orthopaedics and related research.

[15]  Angelo Cappello,et al.  Propagation of anatomical landmark misplacement to knee kinematics: performance of single and double calibration. , 2006, Gait & posture.

[16]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[17]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.

[18]  J S Krouwer,et al.  A simple, graphical method to evaluate laboratory assays. , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.

[19]  Shunji Hirokawa,et al.  A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images , 2008, Medical & Biological Engineering & Computing.

[20]  E R Valstar,et al.  A new model-based RSA method validated using CAD models and models from reversed engineering. , 2003, Journal of biomechanics.

[21]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[22]  A. Greenwald,et al.  The influence of contemporary knee design on high flexion: a kinematic comparison with the normal knee. , 2008, The Journal of bone and joint surgery. American volume.

[23]  Thomas P Andriacchi,et al.  The use of functional analysis in evaluating knee kinematics. , 2003, Clinical orthopaedics and related research.

[24]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[25]  Gerd Hirzinger,et al.  Registration of CAD-models to images by iterative inverse perspective matching , 1996, Proceedings of 13th International Conference on Pattern Recognition.

[26]  Richard D. Komistek,et al.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images , 2003, IEEE Transactions on Medical Imaging.