Utilization of a Glucometer Test Strip and Enzymatic Reactions to Quantify Anti-SARS-CoV-2 Spike RBD IgG Antibody and SARS-CoV-2 Virus in Saliva and Serum
暂无分享,去创建一个
D. Tyrrell | M. Houghton | M. Logan | M. Serpe | M. Joyce | J. Law | Qiming Shen | Faisal Hossain | Nicholas Balasuriya
[1] Ting-Hsuan Chen,et al. Microfluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees , 2022, Science advances.
[2] N. Tabatabaei,et al. Rapid and Low-Cost Detection and Quantification of SARS-CoV-2 Antibody Titers of ICU Patients with Respiratory Deterioration Using a Handheld Thermo-Photonic Device , 2022, Biomedicines.
[3] Stefani N. Thomas,et al. Ultrasensitive detection of salivary SARS-CoV-2 IgG antibodies in individuals with natural and COVID-19 vaccine-induced immunity , 2022, Scientific Reports.
[4] Gaofeng Liang,et al. A Simple and Universal Nucleic Acid Assay Platform Based on Personal Glucose Meter Using SARS-CoV-2 N Gene as the Model , 2022, Biosensors.
[5] J. Vinjé,et al. Development and Validation of an Enzyme Immunoassay for Detection and Quantification of SARS-CoV-2 Salivary IgA and IgG , 2022, The Journal of Immunology.
[6] E. Callaway. Why does the Omicron sub-variant spread faster than the original? , 2022, Nature.
[7] G. Dirani,et al. Fast and real-time electrical transistor assay for quantifying SARS-CoV-2 neutralizing antibodies , 2022, Communications Materials.
[8] M. Serpe,et al. Orthophosphate Quantification in Water Utilizing an Enzymatic Reaction and a Commercial Glucometer Test Strip. , 2022, Analytical chemistry.
[9] C. Welch,et al. Quantitation of Trastuzumab and an Antibody to SARS-CoV-2 in Minutes Using Affinity Membranes in 96-Well Plates , 2022, Analytical chemistry.
[10] F. Long,et al. Rapid and quantitative detection of SARS-CoV-2 IgG antibody in serum using optofluidic point-of-care testing fluorescence biosensor , 2021, Talanta.
[11] Xianjia Peng,et al. Hydrophilicity/hydrophobicity of metal sulfide particles as a determinator of aggregation performance in wastewater , 2021 .
[12] Gheyath K Nasrallah,et al. Evaluation of Antibody Response in Symptomatic and Asymptomatic COVID-19 Patients and Diagnostic Assessment of New IgM/IgG ELISA Kits , 2021, Pathogens.
[13] Y. Xiang,et al. Characterization of SARS-CoV-2-specific antibodies in COVID-19 patients reveals highly potent neutralizing IgA , 2021, Signal Transduction and Targeted Therapy.
[14] A. Öpik,et al. Development of a portable MIP-based electrochemical sensor for detection of SARS-CoV-2 antigen , 2021, Biosensors and Bioelectronics.
[15] A. Sette,et al. Adaptive immunity to SARS-CoV-2 and COVID-19 , 2021, Cell.
[16] C. Day,et al. Antibodies to neutralising epitopes synergistically block the interaction of the receptor‐binding domain of SARS‐CoV‐2 to ACE 2 , 2021, Clinical & translational immunology.
[17] Qianghu Wang,et al. Dynamic changes in anti-SARS-CoV-2 antibodies during SARS-CoV-2 infection and recovery from COVID-19 , 2020, Nature Communications.
[18] A. Gingras,et al. Persistence of serum and saliva antibody responses to SARS-CoV-2 spike antigens in COVID-19 patients , 2020, Science Immunology.
[19] Michael D Healy,et al. SARS-CoV-2 viral load is associated with increased disease severity and mortality , 2020, Nature Communications.
[20] Patricia Harrington,et al. SARS-CoV-2 detection, viral load and infectivity over the course of an infection , 2020, Journal of Infection.
[21] Jun Zhou,et al. One-step rapid quantification of SARS-CoV-2 virus particles via low-cost nanoplasmonic sensors in generic microplate reader and point-of-care device , 2020, bioRxiv.
[22] Natural Sciences and Engineering Research Council of Canada (NSERC) , 2018, The Grants Register 2022.
[23] J. Lammertyn,et al. Evaluation of different strategies for magnetic particle functionalization with DNA aptamers. , 2016, New biotechnology.
[24] M. Meyerhoff,et al. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears. , 2014, Analytical chemistry.
[25] Zhi Zhu,et al. Target-responsive "sweet" hydrogel with glucometer readout for portable and quantitative detection of non-glucose targets. , 2013, Journal of the American Chemical Society.
[26] Yi Lu,et al. Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets. , 2011, Nature chemistry.
[27] M. Marinaro,et al. Detection of Caprine Herpesvirus 1–Specific Antibodies in Goat Sera Using an Enzyme-Linked Immunosorbent Assay and Serum Neutralization Test , 2010, Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc.
[28] Nigel A. Surridge,et al. The Technology Behind Glucose Meters: Test Strips , 2008 .
[29] H. Moon,et al. Comparison of an enzyme-linked immunosorbent assay with serum neutralization test for serodiagnosis of porcine epidemic diarrhea virus infection. , 2005, Journal of veterinary science.
[30] P. Gibbs,et al. Separation and detection of salmonellae using immunomagnetic particles , 1991 .
[31] T. Fukui,et al. Purification and Properties of Maltose Phosphorylase from Lactobacillus brevis , 1973 .
[32] Simon D Tran,et al. Saliva as a diagnostic tool for oral and systemic diseases. , 2016, Journal of oral biology and craniofacial research.
[33] D. Mader. Reptile medicine and surgery , 1996 .