Surface modification of neural recording electrodes with conducting polymer/biomolecule blends.

The interface between micromachined neural microelectrodes and neural tissue plays an important role in chronic in vivo recording. Electrochemical polymerization was used to optimize the surface of the metal electrode sites. Electrically conductive polymers (polypyrrole) combined with biomolecules having cell adhesion functionality were deposited with great precision onto microelectrode sites of neural probes. The biomolecules used were a silk-like polymer having fibronectin fragments (SLPF) and nonapeptide CDPGYIGSR. The existence of protein polymers and peptides in the coatings was confirmed by reflective microfocusing Fourier transform infrared spectroscopy (FTIR). The morphology of the coating was rough and fuzzy, providing a high density of bioactive sites for interaction with neural cells. This high interfacial area also helped to lower the impedance of the electrode site and, consequently, to improve the signal transport. Impedance spectroscopy showed a lowered magnitude and phase of impedance around the biologically relevant frequency of 1 kHz. Cyclic voltammetry demonstrated the intrinsic redox reaction of the doped polypyrrole and the increased charge capacity of the coated electrodes. Rat glial cells and human neuroblastoma cells were seeded and cultured on neural probes with coated and uncoated electrodes. Glial cells appeared to attach better to polypyrrole/SLPF-coated electrodes than to uncoated gold electrodes. Neuroblastoma cells grew preferentially on and around the polypyrrole/CDPGYIGSR-coated electrode sites while the polypyrrole/CH(3)COO(-)-coated sites on the same probe did not show a preferential attraction to the cells. These results indicate that we can adjust the chemical composition, morphology, electronic transport, and bioactivity of polymer coatings on electrode surfaces on a multichannel micromachined neural probe by controlling electrochemical deposition conditions.

[1]  D. Ishii,et al.  Nerve growth factor effects and receptors in cultured human neuroblastoma cell lines , 1982, Journal of neuroscience research.

[2]  G. Laurie,et al.  Biological activities of laminin , 1985, Journal of cellular biochemistry.

[3]  H. Susi,et al.  Examination of the secondary structure of proteins by deconvolved FTIR spectra , 1986, Biopolymers.

[4]  W. Kenan,et al.  Impedance Spectroscopy: Emphasizing Solid Materials and Systems , 1987 .

[5]  R. Timpl,et al.  Laminin and other basement membrane components. , 1987, Annual review of cell biology.

[6]  Yukihide Iwamoto,et al.  Identification of an amino acid sequence in laminin mediating cell attachment, chemotaxis, and receptor binding , 1987, Cell.

[7]  L. Miller,et al.  Poly(N-methylpyrrolylium) poly(styrenesulfonate) - a conductive, electrically switchable cation exchanger that cathodically binds and anodically releases dopamine , 1987 .

[8]  H. Kleinman,et al.  A pentapeptide from the laminin B1 chain mediates cell adhesion and binds the 67,000 laminin receptor. , 1987, Biochemistry.

[9]  K. Wise,et al.  Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity , 1988, IEEE Transactions on Biomedical Engineering.

[10]  David J. Anderson,et al.  Surgical Implantation and Biocompatibility of Central Nervous System Auditory Prostheses , 1989, The Annals of otology, rhinology, and laryngology.

[11]  S. Thanos,et al.  Survival and Axonal Elongation of Adult Rat Retinal Ganglion Cells , 1989, The European journal of neuroscience.

[12]  H. Kleinman,et al.  Two different laminin domains mediate the differentiation of human endothelial cells into capillary-like structures in vitro , 1989, Cell.

[13]  D.J. Anderson,et al.  Batch fabricated thin-film electrodes for stimulation of the central auditory system , 1989, IEEE Transactions on Biomedical Engineering.

[14]  J. Hubbell,et al.  Covalently immobilized laminin peptide Tyr-Ile-Gly-Ser-Arg (YIGSR) supports cell spreading and co-localization of the 67-kilodalton laminin receptor with alpha-actinin and vinculin. , 1993, The Journal of biological chemistry.

[15]  Structure-activity study of a laminin alpha 1 chain active peptide segment Ile-Lys-Val-Ala-Val (IKVAV). , 1995, FEBS letters.

[16]  Gordon G. Wallace,et al.  Integration of biocomponents with synthetic structures: use of conducting polymer polyelectrolyte composites , 1996, Smart Structures.

[17]  S. Das,et al.  Electrochemical preparation and study of transport properties of polypyrrole doped with unsaturated organic sulfonates , 1996 .

[18]  Processing and characterization of protein polymer thin films for surface modification of neural prosthetic devices. , 1997 .

[19]  P. Pickup,et al.  An impedance study of electron transport and electron transfer in composite polypyrrole + polystyrenesulphonate films , 1997 .

[20]  Geoffrey M. Spinks,et al.  Conductive Electroactive Polymers: Intelligent Materials Systems , 1997 .

[21]  R Langer,et al.  Stimulation of neurite outgrowth using an electrically conducting polymer. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[22]  P Aebischer,et al.  Three-dimensional extracellular matrix engineering in the nervous system. , 1998, Journal of biomedical materials research.

[23]  R. Compton,et al.  AFM studies of polypyrrole film surface morphology I. The influence of film thickness and dopant nature , 1998 .

[24]  Conrad D. James,et al.  Patterned Protein Layers on Solid Substrates by Thin Stamp Microcontact Printing , 1998 .

[25]  Qi Hong,et al.  AFM studies of polypyrrole film surface morphology II. Roughness characterization by the fractal dimension analysis , 1998 .

[26]  S. Thanos,et al.  Modification of glassy carbon surfaces with synthetic laminin-derived peptides for nerve cell attachment and neurite growth. , 1998, Journal of biomedical materials research.

[27]  Göran Sundholm,et al.  Polypyrrole as a model membrane for drug delivery , 1998 .

[28]  Buddy D. Ratner,et al.  Template-assisted nano-patterning of solid surfaces , 1998 .

[29]  Teruhisa Komura,et al.  Electron and ion transport in polypyrrole/polystyrenesulfonate composite films , 1998 .

[30]  M. Tirrell,et al.  Cellular recognition of synthetic peptide amphiphiles in self-assembled monolayer films. , 1999, Biomaterials.

[31]  Chronic electrode-brain interface modeled with FEM , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[32]  G G Wallace,et al.  Polypyrrole-heparin composites as stimulus-responsive substrates for endothelial cell growth. , 1999, Journal of biomedical materials research.

[33]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[34]  James D. Weiland,et al.  Chronic neural stimulation with thin-film, iridium oxide electrodes , 2000, IEEE Trans. Biomed. Eng..

[35]  Michael Freemantle,et al.  The Endless Polymer Science Frontier , 2000 .

[36]  John R. Reynolds,et al.  Use of Conducting Electroactive Polymers for Drug Delivery and Sensing of Bioactive Molecules. A Redox Chemistry Approach , 2000 .

[37]  M. A. Johnson,et al.  Chronic recording of regenerating VIIIth nerve axons with a sieve electrode. , 2000, Journal of neurophysiology.

[38]  Mian Jiang,et al.  Toward Genolelectronics: Nucleic Acid Doped Conducting Polymers , 2000 .