Ray Tracing versus Thin-Lens Formulas for IOL Power Calculation Using Swept-Source Optical Coherence Tomography Biometry

Abstract Purpose To evaluate the ray tracing method's accuracy employing Okulix ray tracing software and thin-lens formulas to calculate intraocular lens (IOL) power using a swept-source optical coherence tomography (SS-OCT) biometer (OA2000). Methods A total of 188 eyes from 180 patients were included in this study. An OA-2000 optical biometer was used to collect biometric data. The predicted postoperative refraction based on thin-lens formulas including SRK/T, Hoffer Q, Holladay 1, and Haigis formulas and the ray tracing method utilizing the OKULIX software was determined for each patient. To compare the accuracy of approaches, the prediction error and the absolute prediction error were determined. Results The mean axial length (AL) was 23.66 mm (range: 19–35). In subgroup analysis based on AL, in all ranges of ALs the ray tracing method had the lowest mean absolute error (0.56), the lowest standard deviation (SD; 0.55), and the greatest proportion of patients within 1 diopter of predicted refraction (87.43%) and the lowest absolute prediction error compared to the other formulas (except to SRK/T) in the AL range between 22 and 24 mm (all P < 0.05). In addition, the OKULIX and Haigis formulas had the least variance (variability) in the prediction error in different ranges of AL. Conclusion The ray tracing method had the lowest mean absolute error, the lowest standard deviation, and the greatest proportion of patients within 1 diopter of predicted refraction. So, the OKULIX software in combination with SS-OCT biometry (OA2000) performed on par with the third-generation and Haigis formulas, notwithstanding the potential for increased accuracy in the normal range and more consistent results in different ranges of AL.

[1]  KarimM Nabil,et al.  Accuracy of intraocular lens power calculation using partial coherence interferometry and OKULIX ray tracing software in high myopic cataract patients , 2017 .

[2]  Pipat Kongsap Comparison of a new optical biometer and a standard biometer in cataract patients , 2016, Eye and Vision.

[3]  D. Cooke,et al.  Comparison of 9 intraocular lens power calculation formulas , 2016, Journal of cataract and refractive surgery.

[4]  G. Savini,et al.  Comparison of a new optical biometer using swept‐source optical coherence tomography and a biometer using optical low‐coherence reflectometry , 2016, Journal of cataract and refractive surgery.

[5]  D. Cooke,et al.  Prediction accuracy of preinstalled formulas on 2 optical biometers , 2016, Journal of cataract and refractive surgery.

[6]  L. Asena,et al.  Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 , 2015, British Journal of Ophthalmology.

[7]  D. Mathysen,et al.  Overview of the repeatability, reproducibility, and agreement of the biometry values provided by various ophthalmic devices. , 2014, American journal of ophthalmology.

[8]  G. Savini,et al.  Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster , 2014, British Journal of Ophthalmology.

[9]  K. Tsubota,et al.  Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery , 2014, Japanese Journal of Ophthalmology.

[10]  J. Wolffsohn,et al.  Validity and repeatability of the Aladdin ocular biometer , 2013, British Journal of Ophthalmology.

[11]  C. Lindemann,et al.  Intraocular lens calculation for aspheric intraocular lenses , 2013, Journal of cataract and refractive surgery.

[12]  G. Savini,et al.  A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices , 2012, PloS one.

[13]  P. Preussner,et al.  Accuracy of intraocular lens calculation with ray tracing. , 2012, Journal of refractive surgery.

[14]  T. Olsen,et al.  Ray‐tracing analysis of intraocular lens power in situ , 2012, Journal of cataract and refractive surgery.

[15]  W. Hütz,et al.  Results of higher power toric intraocular lens implantation , 2011, Journal of cataract and refractive surgery.

[16]  G. Savini,et al.  Comparison of 2 laser instruments for measuring axial length , 2010, Journal of cataract and refractive surgery.

[17]  A. Ehmer,et al.  Comparison of ray‐tracing method and thin‐lens formula in intraocular lens power calculations , 2009, Journal of cataract and refractive surgery.

[18]  P. Preussner,et al.  [Comparison between ray-tracing and IOL calculation formulae of the 3rd generation]. , 2009, Klinische Monatsblatter fur Augenheilkunde.

[19]  O. Findl,et al.  Ray tracing for intraocular lens calculation , 2002, Journal of cataract and refractive surgery.

[20]  J S Wolffsohn,et al.  A new non-contact optical device for ocular biometry , 2002, The British journal of ophthalmology.

[21]  L. Drolsum,et al.  Accuracy of IOL calculation in cataract surgery. , 2009, Acta ophthalmologica Scandinavica.

[22]  G. J. Jin,et al.  Prospective evaluation of early visual and refractive effects with small clear corneal incision for cataract surgery , 1996, Journal of cataract and refractive surgery.

[23]  S. Masket,et al.  Astigmatic stabilization of 3.0 mm temporal clear corneal cataract incisions , 1996, Journal of cataract and refractive surgery.

[24]  K. Hoffer,et al.  The Hoffer Q formula: A comparison of theoretic and regression formulas , 1993, Journal of cataract and refractive surgery.

[25]  W. Haigis Occurrence of Erroneous Anterior Chamber Depth in the SRK/T Formula , 1993, Journal of cataract and refractive surgery.