Fast dose calculation in magnetic fields with GPUMCD

A new hybrid imaging-treatment modality, the MRI-Linac, involves the irradiation of the patient in the presence of a strong magnetic field. This field acts on the charged particles, responsible for depositing dose, through the Lorentz force. These conditions require a dose calculation engine capable of taking into consideration the effect of the magnetic field on the dose distribution during the planning stage. Also in the case of a change in anatomy at the time of treatment, a fast online replanning tool is desirable. It is improbable that analytical solutions such as pencil beam calculations can be efficiently adapted for dose calculations within a magnetic field. Monte Carlo simulations have therefore been used for the computations but the calculation speed is generally too slow to allow online replanning. In this work, GPUMCD, a fast graphics processing unit (GPU)-based Monte Carlo dose calculation platform, was benchmarked with a new feature that allows dose calculations within a magnetic field. As a proof of concept, this new feature is validated against experimental measurements. GPUMCD was found to accurately reproduce experimental dose distributions according to a 2%-2 mm gamma analysis in two cases with large magnetic field-induced dose effects: a depth-dose phantom with an air cavity and a lateral-dose phantom surrounded by air. Furthermore, execution times of less than 15 s were achieved for one beam in a prostate case phantom for a 2% statistical uncertainty while less than 20 s were required for a seven-beam plan. These results indicate that GPUMCD is an interesting candidate, being fast and accurate, for dose calculations for the hybrid MRI-Linac modality.

[1]  Steve B. Jiang,et al.  GPU-based ultrafast IMRT plan optimization , 2009, Physics in medicine and biology.

[2]  B G Fallone,et al.  Patient dosimetry for hybrid MRI-radiotherapy systems. , 2008, Medical physics.

[3]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[5]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[6]  B W Raaymakers,et al.  Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength , 2008, Physics in medicine and biology.

[7]  Benoît Ozell,et al.  GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform. , 2011, Medical physics.

[8]  Jan J W Lagendijk,et al.  MRI/linac integration. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  R. Mohan,et al.  The effect of dose calculation uncertainty on the evaluation of radiotherapy plans. , 2000, Medical physics.

[10]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electrons , 2005, Physics in medicine and biology.

[11]  Jean M Moran,et al.  Magnetic confinement of electron and photon radiotherapy dose: a Monte Carlo simulation with a nonuniform longitudinal magnetic field. , 2005, Medical physics.

[12]  B. Fallone,et al.  First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system. , 2009, Medical physics.

[13]  B W Raaymakers,et al.  Experimental verification of magnetic field dose effects for the MRI-accelerator , 2007, Physics in medicine and biology.

[14]  J G M Kok,et al.  Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept , 2009, Physics in medicine and biology.

[15]  J. H. Hubbell,et al.  XCOM : Photon Cross Sections Database , 2005 .