Wireless Instrumented Crutches for Force and Movement Measurements for Gait Monitoring

This paper describes the design, development, and characterization of two wireless instrumented crutches for gait monitoring in order to provide clinicians quantitative parameters of upper limbs' contributions during walking. These parameters could be used to teach orthopedic patients to correctly use these supports and minimize problems connected to their usage. These instrumented crutches allow monitoring axial forces and shear forces, tilt angles, and time of impact on the ground in real time. Each crutch is composed of three strain-gauge bridges for measuring axial and shear forces, a conditioning circuit with transmission module, a triaxial accelerometer, a power management circuit, two batteries, and a biofeedback. The data are wirelessly transmitted via Bluetooth without needing any further readout unit, from the crutches to a personal computer, where the data are processed and displayed by a program created in LabVIEW. Each instrumented crutch was tested to assess the response of the accelerometer and the three strain-gauge bridges using a setup designed ad hoc. The mean experimental standard deviation was about 42 mV for axial forces corresponding to about 8 N and about 35 mV for shear forces corresponding to about 4 N. Hysteresis, linearity, and drift were calculated, and the obtained accuracy was about 8-9 N for axial forces and 4-5 N for shear forces. Furthermore, the crutches were tested during a walking activity of ten healthy subjects along a straight path for several trials. These crutches were used for a common analysis usually reported in the literature for weight bearing evaluation. The subjects were monitored performing a nonweight bearing (NWB) and a partial weight bearing (PWB) during a three-point gait. The results showed a mean of 102% ± 16% for NWB tests and a mean of 19% ±% for 10% PWB tests; these values are in agreement with similar studies in the literature. The simplicity that includes only constitutive strain gauges and a separable circuit board allows the achievement of the objectives of simplicity, ease of use, and noninvasiveness. Therefore, these crutches could be used as a support tool for controlling the use of crutches during walking not only in hospitals but also at home.

[1]  Vedran Bilas,et al.  Measurement of gait parameters from free moving subjects , 2000 .

[2]  Robert B. McGhee,et al.  Estimation of Human Foot Motion During Normal Walking Using Inertial and Magnetic Sensor Measurements , 2012, IEEE Transactions on Instrumentation and Measurement.

[3]  Mauro Serpelloni,et al.  Wireless Instrumented Crutches for Force and Tilt Monitoring in Lower Limb Rehabilitation , 2014 .

[4]  Brooke A. Slavens,et al.  An upper extremity inverse dynamics model for pediatric Lofstrand crutch-assisted gait. , 2011, Journal of biomechanics.

[5]  Henk J Stam,et al.  Predictors of partial weight-bearing performance after total hip arthroplasty. , 2010, Journal of rehabilitation medicine.

[6]  Ruud W Selles,et al.  The difference between actual and prescribed weight bearing of total hip patients with a trochanteric osteotomy: long-term vertical force measurements inside and outside the hospital. , 2007, Archives of physical medicine and rehabilitation.

[7]  Lechosław B. Dworak,et al.  Biomechanical analysis of dynamic parameters of three-point crutch gait in patients after unilateral endoprosthetic hip joint reconstruction , 2014 .

[8]  Edmund Lau,et al.  Prevalence and Costs of Rehabilitation and Physical Therapy After Primary TJA. , 2015, The Journal of arthroplasty.

[9]  Yoshiyuki Sankai,et al.  Wearable Gait Measurement System with an Instrumented Cane for Exoskeleton Control , 2014, Sensors.

[10]  H J Stam,et al.  Techniques for measuring weight bearing during standing and walking. , 2003, Clinical biomechanics.

[11]  A L McDonough,et al.  Some biomechanical aspects of crutch and cane walking: the relationship between forward rate of progression, symmetry, and efficiency--a case report. , 1988, Clinics in podiatric medicine and surgery.

[12]  Marco Tarabini,et al.  Metrological Performances of a Plantar Pressure Measurement System , 2013, IEEE Transactions on Instrumentation and Measurement.

[13]  Holt,et al.  How Accurate Is Partial Weightbearing? , 2004, Clinical orthopaedics and related research.

[14]  A. Paulo Coimbra,et al.  Human Gait Acquisition and Characterization , 2009, IEEE Transactions on Instrumentation and Measurement.

[15]  J. M. Walker,et al.  Pathomechanics and classification of cartilage lesions, facilitation of repair. , 1998, The Journal of orthopaedic and sports physical therapy.

[16]  Anabela Tereso,et al.  Detection of gait events and assessment of fall risk using accelerometers in assisted gait , 2014, 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO).

[17]  T. Mittlmeier,et al.  Partial weight bearing after surgery for fractures of the lower extremity--is it achievable? , 2006, Gait & posture.

[18]  S. Li,et al.  Three-point gait crutch walking: variability in ground reaction force during weight bearing. , 2001, Archives of physical medicine and rehabilitation.

[19]  Mee-Young Kim,et al.  Analysis of Plantar Foot Pressure during the Non-crutch, Two-point, and Four-point Crutch Gait performed by Healthy Volunteers , 2011 .

[20]  S R Simon,et al.  Elbow moment and forces at the hands during swing-through axillary crutch gait. , 1985, Physical therapy.

[21]  N. Tsuda,et al.  Simplified measurement and visualization tool for crutch walk training , 2012, 2012 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM).

[22]  T. Sinkjær,et al.  Restoration of Walking for Paraplegics , 1992 .

[23]  S. Bharadwaj,et al.  Effectiveness of 'rehabilitation in the home' service. , 2014, Australian health review : a publication of the Australian Hospital Association.

[24]  Neil M. White,et al.  Augmenting forearm crutches with wireless sensors for lower limb rehabilitation , 2010 .

[25]  A. Mündermann,et al.  Forearm pressure distribution during ambulation with elbow crutches: a cross-sectional study , 2014, Journal of NeuroEngineering and Rehabilitation.

[26]  Nimrod Rozen,et al.  Toe-touch weight bearing: myth or reality? , 2010, Orthopedics.

[27]  C. Winstein,et al.  Learning a partial-weight-bearing skill: effectiveness of two forms of feedback. , 1996, Physical Therapy.